Reason For Shut In: Well Control
Reason For Shut In: Well Control
Kill Mud
Shut In Methods
Hard
Soft
1
WELL CONTROL
Shut In Practices
Things That Delay Shut In.
Flow / Pit Alarms Not Set (Properly)
Drill Too Far After Drilling Break
Lack of ‘Shut In’ Training
Lack of Maintenance & Testing
Waiting for Instructions
Accumulator Unit Not Working
Not Monitoring Trips
Low Level of Crew Awareness
2
WELL CONTROL
Soft Method Drilling
3
WELL CONTROL
Soft Method Tripping
5
WELL CONTROL
Hard Method Tripping
Line up With Remote Choke Closed.
Install and make up the fully opened SAFETY VALVE in
the Drill String.
Close the Safety Valve
Close Ram Preventer *
Open Choke Line Valve (HCR) at Stack
Pick up and make up Kelly?Top Drive
Open Safety Valve
Record Shut in Pressures and Pit Gain
* API Soft Shut in States BOP
(It Does Not Specify a Ram)
6
WELL CONTROL
Hard V’s Soft
Hard
Quicker
Less to Remember
Smaller Influx
Soft
Slower
Checks if choke line is Clean
Larger Influx
Reduces Water Hammer Effect
7
WELL CONTROL
Top Hole Drilling
Problems
1. Shallow Gas
8
WELL CONTROL
Shallow Gas Wind Direction
200 ft