0% found this document useful (0 votes)
131 views21 pages

Focus Ac1 Access Node: Terminal Multiplexer Add/Drop Multiplexer

The document describes the FOCUS AC1 access node, which is a compact SDH terminal multiplexer and add/drop multiplexer used to provide 2 Mbit/s and ATM services to customer premises. It can provide 21 x 2Mbit/s interfaces, ATM STM-1 interfaces, and acts as a feeder for AC1 STM-4 links in regional and metro networks. The AC1 is compact, fully managed, supports ATM, and can be installed in street cabinets or customer premises in various configurations.

Uploaded by

Jide
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
131 views21 pages

Focus Ac1 Access Node: Terminal Multiplexer Add/Drop Multiplexer

The document describes the FOCUS AC1 access node, which is a compact SDH terminal multiplexer and add/drop multiplexer used to provide 2 Mbit/s and ATM services to customer premises. It can provide 21 x 2Mbit/s interfaces, ATM STM-1 interfaces, and acts as a feeder for AC1 STM-4 links in regional and metro networks. The AC1 is compact, fully managed, supports ATM, and can be installed in street cabinets or customer premises in various configurations.

Uploaded by

Jide
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 21

FOCUS AC1 ACCESS NODE

Terminal Multiplexer
Add/Drop Multiplexer

Customer Service Training


AC1 Introduction
FOCUS AC1 ACCESS NODE (CPE)
Applications
 2 Mbit/s and ATM service to
Customer Premises
Compact SDH TM/ADM or CPE
 Feeder for AC1 STM-4 links/rings
in regional/metro networks

Strengths
120 ohm version
 21x2Mbit/s (120 ohm (RJ-45) or 75 ohm (1.0/2.3 mini
coax) and ATM STM-1 UNI multi-mode (SC) services
 Integrated dual -48/-60 VDC and
115/230VAC power supply
 Most compact and elegant SDH ADM/TM 75 ohm version

on the marked
 Fully managed by NM2100 Element Manager or 2 x STM-1/4 + 21 x 2Mbit/s
Network Management plus
ATM 155 Mbit/s UNI
 Supports ATM for mixed data/voice network.
No need for parallel networks 2
AC1 Introduction
FOCUS AC1 in SDH networks

HX 6200 6200 HX
Trunk/Backbone:
STM-16, STM-64, DWDM LX
LX LX Network
Management
LX

AC4 6200 6200 LX

NM2100

Regional/Metro: LX LX 6200 6200

STM-4, STM-16 LX LX AC4


LX AC1

LX
Access: AC1 AC1 AC1 AC1 AC1

STM-1, STM-4, ATM AC1 AC0


AC0

Edge:
AC1
Fibre, SDH
Optical network
Twisted pair (Leased lines, Copper access Fibre system for
ATM, BB (POTS, ISDN, Data, xDSL) customer premises
services)
3
AC1 Introduction
FOCUS AC1 Applications

Towards Trunk Network Business


Customers

Management system ADM


1 to 8 STM-1 TM1 2Mbit/s
trib per AC1

TM1 34Mbit/s
ADM ADM1 or ADM4 ADM

TM1 STM-1
ADM
Customer
site Dual homing
ATM

21 20191817 16151413 1211109 8 7 6 5 4 3 2 1

21 x 2 Mbit/s
21 x 2 Mbit/s Access Node
4
AC1 Introduction
FOCUS AC1 Multiplexers

 Types of Network Elements


 STM-1 Add Drop Multiplexer, ADM1/1
 STM-4 Add Drop Multiplexer, ADM4/1
 STM-1 Terminal Multiplexer, TM1/1
 STM-4 Terminal Multiplexer, TM4/1

 Connectivity
 VC-12
 VC-3
 VC-4

5
AC1 Introduction
FOCUS AC1 Access node Interfaces
 Optical interfaces
 STM-1, STM-4

 Short haul and long haul optical interfaces


 1300nm and 1500nm fibre Networks
 S-1.1, L-1.2, S-4.1, Application Codes

 Electrical interfaces
 21 x 2 Mbit/s tributary interfaces, 75 or 120 Ohm
 STM-1 electrical aggregate interfaces

6
AC1 Introduction
Optical Transmission Distances

STM-1 STM-4

Application code S-1.1 L-1.1 L-1.2 S-4.1 L-4.1 L-4.2

Wave-length 1300nm 1300nm 1500nm 1300nm 1300nm 1500nm


Attenuation 0-12dB 1-31 dB 2-31 dB 0-12 dB 10-24 dB 10-24 dB
Maximum Dispersion 135 ps/nm 135 ps/nm 270 ps/nm 90 ps/nm N/A 2200 ps/nm

Approx. Distance 0-30km 3-75 km 8-120km 0-30km 25-60 km 40-96km

Access node interfaces

7
AC1 Introduction
FOCUS AC1 - Fits everywhere

Front access Rear access Access Node (CPE)

Street cabinet:
8
AC1 Introduction
FOCUS AC1 ACCESS NODE (CPE)

 21x2Mbit/s Compact SDH TM / ADM or CPE


 120 ohm (RJ-45) or
75 ohm (1.0/2.3 mini coax)
ATM STM-1 UNI multi-mode
(SC) services

 Integrated dual -48/-60 VDC and


115/230VAC power supply 120 ohm version

 Fully managed by NM2100


Element Manager or Network Management

 Supports ATM for mixed data/voice network. 75 ohm version


No need for parallel networks

2 x STM-1/4 + 21 x 2Mbit/s
plus
ATM 155 Mbit/s UNI
9
AC1 Introduction
Configurations in a front access subrack

Examples of possible configurations:

ADM1/TM1 or ADM4 network element with up


to

– 126 x 2 Mbit/s and 2 x STM-1


– 6 x 34 Mbit/s and 2 x STM-1
– 8 x STM-1
– 2 x ATM STM-1 UNI and 2 x STM-1

SF2 subrack or combinations like

– 1 x ATM STM-1 UNI and 1 x 34 Mbit/s


and 42 x 2 Mbit/s and 2 x STM-1

10
AC1 Introduction
Configurations in a rear access subrack

Examples of possible configurations:

 One ADM1/TM1 or ADM4 network element with the


same possibilities as the front access subrack
Two ADM1/ TM1 or ADM4 network elements with the
same possibilities as the front access subrack
Three ADM1/ TM1 or ADM4 network elements with up
to
SR1 subrack – 42 x2 Mbit/s
– 3 x 34 Mbit/s and 21 x 2 Mbit/s
– 2 x STM-1
– 1 x ATM STM-1 UNI+ 21 x 2Mbit/s
or combinations hereof
 Combinations: An example is where 1/3 of the
subrack is occupied by one network element and 2/3
by another like:
– ADM4 with 42 x 2 Mbits and ADM4 with
84 x 2 Mbit/s 11
AC1 Introduction
Configurations in a Rear Access Sub-rack

Examples of configurations in a 200mm sub-rack


 One ADM1/ TM1 or ADM4/TM4
Network element with up to
 42 x 2Mb/s
 3 x 34 Mb/s and 21 x 2Mb/s
 2 x STM-1
 1 x ATM STM-1 UNI + 21x2MB/s
 …...or combinations hereof

 Two power supply cards


– - 48V installation
– Built-in rack-connection field

SC1 Rear Access


200mm Sub-rack

12
AC1 Introduction
AC1 Connectivity ADM 1 and ADM 4

STM-4, STM-1 VC-4 XC STM-4, STM-1


4/1 4/1
2/2
AC1 VC-4
ACCESS NODE 126 TU12’s

VC-12 XC VC-3 XC

VC
12

21 x 2M
13
AC1 Introduction
Application of Sub-deployed lines

STM-1 TM1 21 x 2Mbit/s


sub-deployed
ADM STM-1 sub-deployed

TM1 1 x 34Mbit/s
STM-1 sub-deployed

STM-N
Ring or
Meshed Net
Working path
STM-1 sub-deployed
ADM
Protection path ATM
STM-1 sub- 21 20191817 16151413 1211109 8 7 6 5 4 3 2 1
deployed
21 x 2Mbit/s
14
AC1 Introduction
AC1 SDH Management features
 Performance Monitoring
 BBE, ES, SES, UAS

 Support of SDH synchronisation


 Synchronisation Status Message

 Network Protection Schemes


 Sub-Network Connection Protection SNC/I

 Management via embedded SDH channels


 DCCm, DCCr, TU-12
 IS-IS routing supported

 Password protection on Network Elements


 F and Q interfaces for local and remote control

15
AC1 Introduction
FOCUS AC1 ACCESS NODE Mechanics

Front view:

ATM
2 Mbit/s interfaces
Power

Alarm
Ethernet/F
21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
155 Mbit/s
FOCUSAC1 ACCESS NODE

Rear view:

SDH Network Interfaces Mgmt DC POWER AC POWER


-48/60 V 115/230 VAC
IN OUT IN1 OUT1 IN2 OUT2 CRAFT QECB AUX 50/60 Hz
320mA
Sub-D Sub-D Sub-D
FUSE: 3.15A
Class 1 Laser Product

16
AC1 Introduction
FOCUS AC1 ACCESS NODE TM Electric
AUX ports and
Craft interface

Access Node

EE

SDH
21 x 2 Mbit/s
Aggr. interface
MUX 120 ohm
STM-1
Electrical STM-1

PS

220/110 V AC
or 48 V DC
17
AC1 Introduction
FOCUS AC1 ACCESS NODE TM Optical

AUX ports and


Craft interface

Access Node

OE

SDH 21 x 2 Mbit/s
Aggr. interface 120 ohm
MUX
STM-1
Single mode fibre

PS
21 x 2 Mbit/s

220/110 V AC
or 48 V DC
18
AC1 Introduction
FOCUS AC1 ACCESS NODE ADM Optical
AUX ports and
Craft interface

Access Node

OEO
2 * Aggr. interfaces
2 * STM-1 SDH
Single mode fibre 21 x 2 Mbit/s
ADM 120 ohm

PS

220/110 V AC
or 48 V DC
19
AC1 Introduction
FOCUS AC1 ACCESS NODE Variants
Craft port
AUX, Qecb
FOCUS Access Node
(ADM OEO without ATM)
DB9 x 3
Power LED
AUX0 Alarm LED

21
Aggr. interface FC/PC ADM1
21 x 2 Mb/s

FAN Fan failure AUX1


Filter/fuse

AC/DC 48V/+-5V
110/220 VAC

main prot
48V in front
20
AC1 Introduction

You might also like