The document discusses blowout preventer (BOP) configurations and rated working pressures. It defines rated working pressure as the maximum internal pressure equipment is designed to contain. A BOP stack's required working pressure is based on maximum anticipated surface pressure from formation pressure minus hydrostatic pressure. BOP stacks are identified by arrangement codes like S for spool and R for ram BOP. An example stack of 10k-135/8-SRRA has a rated working pressure of 10,000 psi and 135/8 inch bore with a spool and two ram BOP arrangement. Diagrams show common BOP stack arrangements.

Uploaded by

Farouq Eng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
225 views

BOP Configurations

The document discusses blowout preventer (BOP) configurations and rated working pressures. It defines rated working pressure as the maximum internal pressure equipment is designed to contain. A BOP stack's required working pressure is based on maximum anticipated surface pressure from formation pressure minus hydrostatic pressure. BOP stacks are identified by arrangement codes like S for spool and R for ram BOP. An example stack of 10k-135/8-SRRA has a rated working pressure of 10,000 psi and 135/8 inch bore with a spool and two ram BOP arrangement. Diagrams show common BOP stack arrangements.

Uploaded by

Farouq Eng
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 12

BOP configuration

Rated Working Pressure


API RP 53 gives the following definition of
Rated Working Pressure (RWP):
The maximum internal pressure that
equipment is designed to contain or control.
The required working pressure of the BOP stack for a
particular well is based on the maximum anticipated
surface pressure.
This is determined from the maximum anticipated
formation pressure, less the hydrostatic pressure of a
column of gas back to surface.
Rated Working Pressure
API documentation uses codes for designation
of BOP stack arrangements.
G = rotating head
A = annular type BOP
R = single ram type BOP
Rd = double ram type BOP
Rt = triple ram type BOP
S = drilling spool with side outlet
connections for choke and kill lines.
BOP stack
A BOP stack may be
fully identified by a
very simple
Ram designation, such as:
10k-135/8-SRRA
Ram

This BOP stack would


have a RWP of 10,000
psi, a throughbore of
135/8 inches and
Fig 1

arranged as shown
Arrangement SA

Fig 2
Arrangement
SRR
Ram

Ram

Fig 3
Arrangement
SRA

Ram

Fig 4
Arrangement
RSR
Ram

Ram

Fi g 5
Arrangement
SRRA

Ram

Ram

Fi g 6
Arrangement
RSRA

Ram

Ram

Fig 7
Arrangement
RSRRA

Ram

Ram

Ram

Fig 8
Arrangement
SRRRA

Ram

Ram

Ram

Fig 9