AP Building Rules
AP Building Rules
on
AP Building Rules – 2017
G.O.Ms.No.119 dated 28.03.2017
including amendments
(G.O.Ms.No.223, Dt.09-07-2018)
(G.O.Ms.No.401, Dt.15-11-2017)
AP Building Rules -2017
G.O.Ms.No.119 dated 28.03.2017
Part-A
Minimum Size, Width and Height
of different components of
residential premises
Minimum Size, Width and Height of different components
of residential premises
Minimum Requirement Minimum Requirement for
for a Dwelling Unit up to a Dwelling Unit above
Componen 50sq.m 50sq.m
S.
ts of
No. Area Width Height Area (sq. Width Height
Building (sq. m) (m) (m) m) (m) (m)
Habitable
1 7.5 2.1 2.75 9.5 2.4 2.75
Rooms
2 Kitchen 3.3 1.8 2.75 4.5 1.8 2.75
3 Pantry - - - 3.0 1.4 2.75
Kitchen with
4 7.5 2.1 2.75 7.5 2.1 2.75
Dining area
5 Bathroom 1.2 1.0 2.2 1.8 1.2 2.2
6 WC 1.0 0.9 2.2 1.2 0.9 2.2
Combined
7 1.8 1.0 2.2 2.8 1.2 2.2
Bath & WC
Contd..
Minimum Requirement Minimum Requirement
for a Dwelling Unit up to for a Dwelling Unit above
Component
S. 50sq.m 50sq.m
s of
No. Area Width Height Area (sq. Width Height
Building (sq. m) (m) (m) m) (m) (m)
Door ways
(Habitable - 0.9 2.1 - 0.9 2.1
rooms)
8
(Kitchen, Bath,
- 0.75 2.0 - 0.75 2.0
WC)
Contd..
Minimum Abutting Existing Road Width Required
Minimum abutting existing
Category Type/Use of Building Plot permissible road width required
(in meters)
SITES IN NEW AREAS/APPROVED LAYOUT
B AREAS
i Basic level social amenities like Nursery
School, Primary School
ii Dispensary/Diagnostic Laboratory/Poly-
Clinic
iv Religious Place
Contd..
Minimum Abutting Existing Road Width Required
Minimum abutting existing
Category Type/Use of Building Plot permissible road width required
(in meters)
i Commercial Complex
ii Computer units/Office Building, ITES Complex
iii Assembly Hall/Cinema Theater /Community Hall/ Function
Hall/Marriage Hall
iv General Industry/ Godown
v Group Development Scheme;
vi Group Housing with more than 100 units, 12
B2
vii High Rise Buildings/Complexes up to height of 24 meters
viii High School/Middle School/Junior College/Tutorial Institution
ix Non High Rise Group Housing (Cellars as applicable + 6 floors)
x Nursing Home/Hospital of not more than 20 beds
xi Others not specified in the Table and all Non High-Rise
buildings up to 18m height
xii Petrol / Diesel / Gas Filling Station/LPG
Contd..
Minimum Abutting Existing Road Width Required
Minimum abutting
existing road width
Category Type/Use of Building Plot permissible
required
(in meters)
Restaurants
i Smaller Restaurants (without lodging) in
site area below 200 sq.m –9.00 m. 9
ii
Restaurants coming up in plot sizes 200
sq.m and above – 12.00 m.” 12
B2 (As per amendments of G.O.Ms.No.401,
Dt.15-11-2017)
xiv
Service establishment
12
xv Workshop
Contd..
Minimum Abutting Existing Road Width Required
Less than
1 7 1.5 1.5 3 3 3 -
50
7 1.5 1.5 3 3 3 -
2 50-100 -
10 1.5 1.5 3 3 3 0.5
7 2 3 3 4 5 1.0
4 200 - 300 Stilt floor
10 2 3 3 5 6 1.5
7 3 4 5 6 7.5 1.5
5 300 - 400 Stilt floor
12 3 4 5 6 7.5 2.0
7 3 4 5 6 7.5 2.0
Contd..
Minimum Setbacks and Height Permissible
7 3 4 5 6 7.5 2.5
* 500 -
7 Stilt floor 12 3 4 5 6 7.5 3.0
750
15 3 4 5 6 7.5 3.5
Contd..
Group Development Schemes
Minimum of 10% of net site area shall be earmarked as organized open
space and be utilized as greenery and shall be provided over and above
the mandatory setbacks at suitable location accessible to entire
community to the satisfaction of the competent authority. Such open
space shall be open to sky.
No additional or proportionate open space charges need to be levied in
such schemes.
These shall not be applicable in case of Government sponsored Housing
Scheme/approved Non-Government Organizations (NGOs) or private
schemes, and the guidelines and requirements as given in the National
Building Code for Low Cost Housing / Government orders shall be
followed.
The Building setbacks shall be as per the type of housing &
requirements given above for the said type of housing and as per Table -
17 and Table – 18.
Contd..
Group Development Schemes
The open space to be left between two blocks also shall be
equivalent to the setback mentioned in Column – (J) of
Table-17 and Column – (E) of Table- 18 for Non High Rise
& High Rise buildings respectively.
A thorough public access road of 12m width with 2-lane
black topped is to be developed within the applicant’s site on
any one side at the periphery / as per suitability and
feasibility for the convenience of accessibility to improve the
circulation pattern in the locality to satisfaction of the
competent authority. This condition would not apply if the
site is surrounded by proper road circulation network as per
the planning standards to the satisfaction of competent
authority.
Contd..
Group Development Schemes
Road requirements:
(a) 9m to 18m for main internal approach roads;
(b) 9m for other internal roads and also for looped roads.
(c) 8m for cul-de-sacs roads (with a minimum radius 9m.) between
50-100m length.
All roads and open spaces mentioned in this Rule shall be handed
over to local body at free of cost through a registered gift deed in the
format prescribed by the Government before issue of occupancy
certificate. The society / association of Residents are responsible for
utilizing, managing and maintaining the roads and open spaces. In
case of any violation or encroachment, the local authority shall
summarily demolish the encroachments.
High Rise Buildings/Complexes
High Rise Buildings/Complexes
High Rise Building means a building with 18m or more in height.
Chimneys, cooling towers, boiler rooms, lift machine rooms, cold
storage and other nonworking areas in case of industrial buildings
and water tanks and architectural features in respect of other
buildings are excluded in including the height.
Contd..
Application for High rise building:
Prior No Objection Certificate (NOC) from the Andhra
Pradesh State Disaster Response & Fire Services Department
[APSDR&FSD] For all High Rise Buildings prior No
Objection Certificate (NOC) from the Andhra Pradesh State
Disasters Response & Fire Services Department shall be
obtained and copy of the approved plan and No Objection
Certificate (NOC) issued by the said department shall be
enclosed along with the building application.
The facilities for providing fire protection and firefighting
facilities in such buildings should be in compliance with the
stipulations laid down and clearance issued by the Andhra
Pradesh State Disaster Response & Fire Services Department
as required under Andhra Pradesh Fire Service Act,
1999)/National Building Code of India (NBC)-2005 from time
Contd..
Application for High rise building:
The designs and installations regarding fire protection and
safety measures including exit requirements and smoke
containment and smoke management measures shall be
undertaken through a fire engineer/fire consultant.
Buildings shall be designed for compliance with earth quake
resistance and resisting other natural hazards. The Completion
Certificate shall mention that the norms have been followed in
the design and construction of buildings for making the
buildings resistant to earthquake, compliance with structural
safety and fire safety requirements.
The building requirements like size and area requirements of
habitable rooms, kitchen, bathrooms and Water closets, other
areas, corridor and staircase widths, service ducts, etc. and
standards as specified in these rules and in National Building
Code-2005 shall be complied with. Contd..
Location and Plot Area
High Rise Buildings/Complexes shall be permissible only in
areas notified by the Sanctioning Authority with prior approval
from the Competent Authority from time to time.
High Rise Buildings/Complexes shall not be permissible in
congested areas and in gram kantam areas.
The minimum plot area shall not be less than 2000sq.m.
In respect of sites/plots proposed for high rise buildings and
affected in road widening where there is a shortfall of the net
plot size, up to 10% of such shortfall in net plot area would be
considered with the proposed height and corresponding
minimum all round setbacks.
Contd..
Means of access
A plot/site shall abut on a public road/public street with a
minimum width of 12m.
Main entrances to the premises shall be of adequate width to
allow easy access to the fire engine and in no case it shall
measure less than 6 m. The entrance gate shall fold back
against the compound wall of the premises, thus leaving the
exterior access way within the plot free for movement of fire
service vehicles. If archway is provided over the main entrance
the height of the archway shall not be at a height less than 5m.
Contd..
Minimum abutting road width and all-round open
space / setback for High Rise Buildings
Height of building
(in meters) Minimum abutting road Minimum
S.No. width all-round open space
Above Up to (in meters) (in meters)
1 - 21 12 7
2 21 24 12 8
3 24 27 18 9
4 27 30 18 10
5 30 35 24 11
6 35 40 24 12
7 40 45 24 13
8 45 50 30 14
9 50 55 30 16
10 After 55m 0.5m additional setback for every 5m of height shall be
insisted Contd..
The open space to be left between two blocks shall be
equivalent to the open space mentioned in Column – (E) of the
above Table and this shall not be considered for organized
open space (Tot lot).
In case of high rise buildings up to 30m height, it is permitted
to transfer up to 2m of setback from one side to the other side,
which needs to be uniform at any given point, subject to
maintaining the minimum setback of 7m on all sides and not
exceeding the permissible/allowable plinth area.
The balcony projection of up to 2m may be allowed projecting
onto the open spaces for upper floors from 6m height onwards.
Where the lighting and ventilation of a building is through the
means of a chowk or inner courtyard or interior open
space/duct, such open space shall be open to sky and area of at
least 25sq.m and no side shall be less than 3m. Contd..
In every high rise building site, an organized open space shall
be utilized as greenery, tot lot or soft landscaping, etc. and this
shall be provided over and above the mandatory setbacks to be
left in and around the building. This space shall be at least
10% of total site area at ground level open to sky and shall be a
minimum width of 4.5m. This may be provided in one or more
pockets with minimum area of 50sq.m at each location.
A minimum of 2m wide green planting strip in the periphery
on all sides within the setbacks where the setback is 9m and
above has to be developed and maintained.
Contd..
Buildings abutting major road of 30m and above width shall
be permitted only after providing black-topped service roads of
minimum 7m width with minimum 2 Lane carriageway within
the defined right of way. It will be the responsibility of the
developer/builder/owner to provide the above service road of
the standards fixed by the Sanctioning Authority at his own
cost. The Sanctioning Authority may consider sanctioning
building permission if the developer/builder/ owner deposits
the full cost for laying such service road to the Sanctioning
Authority. The amount so levied and collected shall be
maintained in a separate exclusive account by the Sanctioning
Authority and utilized only for this purpose.
AP Building Rules -2017
G.O.Ms.No.119 dated 28.03.2017
Part-C
Parking
Parking Requirements in Buildings
Parking area to be provided
as percentage of total built up area
1 Multiplexes 60 50
2
Information Technology Enabling
Services Complexes, 50 40
Shopping Malls (above 4000sq. m)
3
Business buildings, Cinema halls,
Hotels, Kalyana Mandapams,
Lodges, Offices, Other Commercial
30 25
buildings, Restaurants & High-Rise
Buildings / Complexes of Non
Residential Category
4
Colleges, Godowns, Hospitals,
Industrial buildings, Institutional
buildings, Residential Apartment 20 20
Complexes, Schools, Educational
Buildings & Other Buildings Contd..
Visitors parking
Visitors’ parking shall be provided with minimum 10% of the
parking area mentioned in the above Table (Parking Area to be
provided in all Buildings) and may be accommodated in the
mandatory setbacks other than front setback where ever such
setbacks are more than 6m (excluding green strip). However
this is not permissible in case of transfer of setback. The
Visitors’ Parking facility shall be open to all visitors which
shall be properly demarcated on ground.
Travel distance
Travel Distance for Occupancy and Type of Construction
S.No Group of Occupancy Maximum Travel Distance Construction (m)
Contd..
(4) Multiplex Complex shall not be allowed in
(a) Congested areas;
(b) Settlement areas/Abadi/Gram khantam areas;
(c) Areas restricted for High-rise buildings;
(d) Abutting to major road junctions of above 18m wide;
(e) Pure residential areas/localities.
(5) Government may by Notification, declare certain
roads/areas in any APCRDA/MRDA/UDA/ULB area
where Multiplex Complex shall not be allowed.
Contd..
Documents to be submitted:
In addition to the documents required to be submitted for
sanction of building permission of High rise building, the
following are also mandatory to examine the Multiplex
Complex Application.
Prior No Objection Certificate shall be submitted from the
Airport Authority of India (if applicable).
Prior No Objection Certificate shall be submitted from the
Director General of Disaster Response and Fire Services
Department. The fire safety requirements shall be duly
certified by a fire engineer.
Prior No Objection Certificate from the Police Department
[Traffic] shall be submitted.
Traffic Impact Study Report and Traffic Management Plan for
the proposed Multiplex Complex prepared by a qualified
Traffic Engineer shall be submitted along with application.
Contd..
Building Requirements:
Every application to construct or reconstruct a Multiplex
Complex shall be made in the prescribed form and
accompanied by detailed plans and floor plans of all floors
drawn by a registered architect, along with complete set of
structural drawings and detailed specifications duly certified
by a qualified structural engineer.
The building bulk, coverage and height shall be governed by
the minimum all-round setbacks to be left, the organized open
spaces to be left and the height restrictions imposed by the
Airport authority (if applicable)/Defense authorities (if
applicable) and Fire Services Department and the Area-level
Impact fee on built up area required to be paid, as applicable.
The maximum height of the block/portion wherein the
Multiplex screens are set up shall not exceed 30m; Contd..
Building Requirements:
In case of sites located in Gram Panchayat areas and
outside Development Authority areas, the maximum
height of all blocks permissible shall be 30m;
In case of two or more blocks in the same site, the space
between the two blocks shall be as given in Column (D)
of the Table given below;
For heights of blocks above 30m and up to 45m, the
minimum abutting road width shall be 24m while for
blocks of height above 45m, the minimum abutting road
width shall be 30m.
The minimum all-round setbacks for a multiplex
Complex shall be as follows.
No relaxation in the minimum all-round setbacks or
transfer of setbacks shall be allowed. Contd..
Minimum all-round setbacks for a Multiplex
Complex
S.No. Height of the Building Minimum front open space Minimum open space on
(m) (m) remaining sides (m )
1 Up to 15 6
10 Above 50m 15 16
Contd..
Building Requirements:
In case of sites located in Gram Panchayat areas and
outside Development Authority areas, the maximum
height of all blocks permissible shall be 30m;
In case of two or more blocks in the same site, the space
between the two blocks shall be as given in Column (D)
of the Table given below;
For heights of blocks above 30m and up to 45m, the
minimum abutting road width shall be 24m while for
blocks of height above 45m, the minimum abutting road
width shall be 30m.
The minimum all-round setbacks for a multiplex
Complex shall be as follows.
No relaxation in the minimum all-round setbacks or
transfer of setbacks shall be allowed. Contd..
Parking requirements for Multiplex Complex
Parking area to be provided as percentage of total built up
area (inclusive of all internal aisles, driveways, stairs, etc.)
Type of Building
In Municipal Corporation
In other areas
areas
Multiplex Complexes
60% 50%
(inclusive of all activities areas)
basements or cellars or
on stilt floor or
in the open space over and above the minimum required
setbacks (except the front setback) to be left around the
building with adequate vehicular access, aisle, drives, ramps
required for maneuvering of vehicles.
Multi-Level Parking Complex [MLPC] adjoining to the
complex within the site may be considered provided that a
minimum clear open space of 6 m from the site boundary is
Contd..
Landscaping and greenery:
A minimum 2 m wide green planting strip in the periphery on
all sides within the setbacks are required to be developed and
maintained
In addition to (a) above, an organized open space of at least
10 % of total site area shall be maintained and utilized as
greenery over and above the mandatory alround setbacks.
This could be part of the interior open space or be in one or
more pockets.
The landscaping and greenery shall be undertaken as per the
guidelines given in the National Building Code and subject to
provision of hard and motorable leveled ground to facilitate
operation of Hydraulic Platform.
Trees shall be planted within the periphery of the site at the
rate of 1 tree per 100 sq m of site area.
Category wise Minimum Size of
Plots
(As per amendments of
G.O.Ms.No.401, Dt.15-11-2017)
Category wise Minimum Size of Plots
S.No. Category Minimum Plot
Size
Cinema Theatre / Convention Center/Game
(1) Center/ Kalyana Mandapam / Marriage hall / 2000
Social clubs and amenities
(2) Educational Institution
(a) High School / Residential School 6000
(b) Junior college 4000
(c) Degree College 6000
(d) Technical Educational Institution 10000
(3) Group Development Scheme 4000
(4) LPG Storages 500
Contd..
Category wise Minimum Size of Plots
S.No. Category Minimum Plot Size
Contd..
Electrical Lines
High tension Electricity Transmission lines .Minimum 3 M
Vertical and Horizontal distance
Low Tension Electricity Lines, Minimum 1.5 M Vertical and
Horizontal distance
Contd..
Airport
Building heights are regulated as per the stipulations of the
Airport Authority of India as notified in Gazette of India
Slaughter House, Meat shops, solid waste disposal sites
which may encourage collection of high flying birds, shall not
be permitted within 10km from Airport reference point.
Defence boundary
Defence
Prior clearance from
defence authority is
required for sites within 500
M
Contd..
RELIGIOUS STRUCTURES PROTECTED MONUMENTS
In case of Sites located within a
100m to 200m After prior approval
radius of 100m from the notified
from National Monument Authority
religious structure from time to
time by the sanctioning
authority, the construction is
allowed up to 12m height only.
Notified Religious
Upto 100m no
Structure construction
Protected is allowed
Boundary monument
Bld
12 M g h t
u pto
100M
M
M -
Non-
300
H igh ris
0
e
10
Contd..
Oil/Gas Pipelines
1 90 60
2 60 37
3 30 22
4 18 13
Environmental Impact Assessment Notification-2006:As per the
provisions laid under the EIA Notification S.O.1533, Dt.14.9.2006 and
it’s amendment dt.01.12.2009 issued by MOE&F, GOI and
Notifications issued from time to time with reference to “Building /
Construction Projects/Area Development Projects and Townships”
complying with the following threshold limits fall under category B
and are required to obtain prior Environmental Clearance (EC) from
State Environmental Impact Assessment Authority (SEIAA), Ministry
of Environment and Forests, Government of India.
Building/Construction Projects/Area Development Projects and Townships
8(a) Buildings and >20000sq.m and <1,50,000sq.m #(Built up area for covered
Construction of built up area# construction; in case of facilities open
Projects to the sky, it will be the activity area
8(b) Townships and Covering an area > 50ha and or ++All Projects under Item8(b) shall be
Area built up area >1,50,000sq.m ++ appraised as Category B1
Development
Projects
Green Buildings
Modern buildings consume about 25 to 30 percent of total energy,
and up to 30 percent of fresh potable water and generate
approximately 40 percent of total waste.
As defined by the Indian Green Building Council (IGBC), a green
building is “one which uses less water, optimizes energy efficiency,
conserves natural resources, generates less waste and provides
healthier spaces for occupants, as compared to a conventional
building.”
The “Andhra Pradesh Energy Conservation Building Code
(APECBC)” [Amended Andhra Pradesh Building Rules, 2012]
issued in G. O. Ms. No. 30 Dated: 28.01.2014 is applicable to
commercial buildings and other Non-Residential Buildings that
have a plot area of more than 1000 Square Meters or built up area
of 2000 Square Meters and certain categories of buildings such as
Multiplexes, Hospitals, Hotels and Convention Centers
irrespective of their built up area.
Rain Water Harvesting Structures :
It is mandatory to construct Rain Water Harvesting
Structures in all commercial, public buildings and new
buildings on plots of 200sq.m and above. Clearance of plan
for the construction of new buildings of the aforesaid
categories shall only be given if they have a provision in the
building design itself for Rain Water Harvesting Structures.
Provision of Rain Water Harvesting Structures is mandatory
to issue Occupancy Certificate.
In case of failure in construction of the rain water
harvesting structures by the applicant, the ULB shall levy a
penalty equivalent to additional 10% of Property Tax till the
rain water harvesting structures are constructed and
maintained.
SOLAR ENERGY SYSTEMS IN BUILDINGS