CSSD Project Final Project
CSSD Project Final Project
PREPARED BY
RIYA SAJJAN
MBA HEALTHCARE 1ST YEAR
TABLE OF CONTENT
SR NO PARTICULARS PAGE NO
1 INFORMATION ABOUT
INDRAPRASTHA APOLLO
HOSPITAL
3 METHODOLOGY
4 INTRODUCTION OF CSSD
5 FUNCTION OF CSSD
6 LOCATION OF CSSD
7 STAFF
9 RECEVING AREA
TABLE OF CONTENT
SR NO PARTICULARS PAGE NO
10 CLEANING AREA
11 PACKING AREA
12 STERILIZING AREA
13 STORE
14 DISTRUBATION AREA
17
18
INFORMATION INDRAPRASTHA APOLLO HOSPITAL
INTRODUCTION
PATIENT CARE
Established by Dr Prathap C Reddy in 1983, Apollo Healthcare has a robust
presence across the healthcare ecosystem. From routine wellness &
preventive health care to innovative life-saving treatments and diagnostic
services, Apollo Hospitals has touched more than 120 million lives from over
120 countries, offering the best clinical outcomes. Indraprastha Apollo Hospital
Delhi is Best Hospital in Delhi.
11,000+ Healing Hands - Largest network of the world’s finest and
brightest medical experts who provide compassionate care using
outstanding expertise and advanced technology.
OBJECTIVES
•TO STUDY ORGANISATION AND WORKING OF CENTRAL STERILE
SUPPLY DEPARTMENT.
STERILIZING.
CSSD TECHNICIANS
CSSD ASSISTANTS
HOUSEKEEPING STAFF
WORK FLOW AND SPACE PLANNING
MAJOR ACTIVITIES IN A CSSD ARE:
CLEANING
PACKING
STERILIZING
STORING (TEMPORARY)
AFTER THE INSTRUMENTS ARE WASHED, THEY ARE DRIED IN OVEN DRYER AND SHIFTED TO
PACKING AREA.
IF USED ITEMS ARE NOT DECONTAMINATED IN USER DEPARTMENT THAN BLOOD/ BODY
FLUID SOILED SHOULD BE DECONTAMINATED WITH SODIUM HYPOCHLORITE BEFORE
HANDLING FURTHER.
PACKING AREA
CLEAN AND DRY INSTRUMENTS ARE PACKED BEFORE STERILIZATION SO THAT THEY ARE
NOT CONTAMINATED WHILE HANDLING AFTER THEY ARE STERILIZED. WORKING COUNTERS
ARE REQUIRED IN THIS AREA. MOST OF THE INSTRUMENTS ARE PACKED IN TRAYS (TRAY
ASSEMBLY) THAT ARE WRAPPED WITH DOUBLE LAYER OF COTTON CLOTH. PAPER
ENVELOPES ARE ALSO AVAILABLE FOR PACKING THE INSTRUMENTS. THESE ARE EQUALLY
EFFECTIVE BUT EXPANSIVE. PLASTIC BAGS (ETO BAGS) ARE USED FOR PACKING THE ITEMS
FOR ETO STERILIZATION. THE PACKS ARE LABELED INDICATING DATE OF STERILIZATION
AND DATE OF EXPIRY (WHEREVER POSSIBLE).
SEALING MACHINE IS USED FOR THE SEALING THE PLASTIC BAGS IN WHICH INSTRUMENTS
ARE PACKED. AFTER PACKING AND SEALING, THE INSTRUMENTS ARE SHIFTED FOR
STERILIZATION.
A LARGE QUANTITY OF COTTON BALLS AND GAUGE PIECES ARE USED IN VARIOUS PATIENT
CARE AREAS AND ARE REQUIRED TO BE STERILIZED BEFORE USING THEM. TRADITIONALLY
THESE ARE PREPARED IN THE CSSD. CUTTING THE GAUGE IS VERY ARDUOUS JOB AND IS
DONE WITH THE HELP OF GAUZE CUTTING MACHINE. DURING THE PROCESS OF GAUGE
CUTTING, THE COTTON FIBERS ARE DISPERSED IN THE AIR AND MAY GET SETTLED ON THE
STERILIZED ITEMS SPOILING THEM. THEREFORE, A SEPARATE ROOM IS REQUIRED FOR
CUTTING THE GAUGE AND PREPARING COTTON BALLS ADJACENT TO THE PACKING AREA.
STERILIZING AREA
STERILIZATION IS DONE BY EITHER OF THE TWO METHODS IN CSSD:
ENSURE THE EQUIPMENT IS FIT I.E. IN AUTOCLAVE THE TEMPERATURE IS MAINTAINED AT 121 DEGREES
CENTIGRADE, 15-POUND PRESSURE AND HOLDING TIME IS MINIMUM 20 MINUTES. MODERN MACHINES
ASSURE THAT AND ARE FITTED WITH GOOD QUALITY MONITORS. THEY PROVIDE PRINT OUTS OF READINGS.
THE DOORS OF THE AUTOCLAVE DO NOT OPEN UNLESS THE CYCLE IS COMPLETE.
BOWIE DICK’S TAPES ARE FIXED WITH EVERY PACK OF ITEMS TO BE STERILIZED. THIS TAPS CHANGES THE
COLOR WHENEVER THE REQUIRED TEMPERATURE IS ATTAINED. AFTER A CYCLE, THE TAPES ARE CHECKED
FOR CHANGE OF COLOR. HOWEVER, THE CHANGE IN COLOR ONLY INDICATES THAT THE SPECIFIC
TEMPERATURE HAS BEEN ACHIEVED DURING THE CYCLE BUT CANNOT GUARANTEE THAT THE ITEMS ARE
STERILIZED. INDICATORS ARE ALSO AVAILABLE FOR CHECKING THE QUALITY OF ETO STERILIZATION.
THE STAFFS WHO WORK ESPECIALLY IN STERILIZATION AREA, STERILE STORE AND DISTRIBUTION AREA
SHOULD CHANGE SLIPPERS AND THEIR DRESS, AND WASH THEIR HANDS BEFORE RESUMING WORK.
LIFE OF STERILIZED ITEMS
GLOVES
SUTURING SET
TRACHEOTOMY SET
CVP SET
BURN PACK
SEALING MACHINE.
CSSD
INSTRUMENTS
APPLIANCES
DRESSINGS
SPONGES
OT LINEN
SPECIAL PACKS
GAUZE AND COTTON MATERIALS
GLOVES
BOWLS AND TRAYS
REGISTERED MAINTAINED IN CSSD
AUTOCLAVE IN TIME – OUT TIME REGISTER
OT REGISTER
CARDIAC OT REGISTER
WARD REGISTER
LABOUR OT
ROOM
PROCEDURE
RINSING: RINSING OF ARTICLES AFTER USE SHOULD NOT BE PERMITTED IN PATIENT CARE AREAS UNLESS
CARRIED OUT BY A TRAINED MEMBER OF THE STAFF
INSPECTION AND ASSEMBLY: EACH ITEM SHOULD BE INSPECTED FOR FUNCTIONALITY, DEFECTS, BREAKAGE AND
THEN APPROPRIATELY ASSEMBLED
CLEANING: ALL REUSABLE MEDICAL DEVICES SHOULD BE THOROUGHLY CLEANED PRIOR TO DISINFECTION OR
STERILIZATION.
LABELLING: EACH PACK SHOULD BE MARKED WITH NOMENCLATURE OF THE ARTICLE, CONTENTS OF THE PACK,
INITIALS OF THE PERSON WHO PACKED IT, DATE AND INITIALS OF THE PERSON WHO CARRIED OUT THE
STERILIZATION.
STERILIZATION: THE OPERATION OF THE STERILIZER SHOULD BE ENTRUSTED TO A RESPONSIBLE AND FULLY
TRAINED PERSON. IT SHOULD BE KEPT IN A STATE OF GOOD MAINTENANCE AND REPAIR.
STORAGE: SHOULD BE PROPERLY MANAGED SEPARATELY FOR STERILE AND NON-STERILE STORES. FOR
STERILE GOODS, CLEAN ROOM CONDITIONS SHOULD BE FOLLOWED.
DISTRIBUTION: REFERS TO CLEAN AND DIRTY ARTICLES EXCHANGE SYSTEM. A PROGRAM SHOULD BE
ESTABLISHED FOR THE COLLECTION OF USED ITEMS FROM PATIENT CARE AREAS AND DISTRIBUTION OF
STERILIZED GOODS.
STERILITY INDICATORS
MECHANICAL INDICATORS: ARE MONITORING INSTRUMENTS WHICH RECORD TIME, TEMPERATURE, HUMIDITY
AND PRESSURE DURING THE STERILIZATION CYCLE.
CHEMICAL INDICATORS: ARE DEVICES WITH A SENSITIVE CHEMICAL OR DYE TO MONITOR ONE OR MORE
PARAMETERS OF A STERILIZATION CYCLE.
IN ADDITION, CHEMICAL INDICATORS PLACED INSIDE CHANGE COLOR WHEN CONDITIONS NECESSARY FOR
STERILIZATION HAVE BEEN MET. THESE ARE AVAILABLE AS TAPES AND STRIPES, AND ARE ATTACHED OR
IMPLANTED INSIDE THE PACKING MATERIAL.
THIS SHOULD BE SUPPLEMENTED WITH PERIODICAL USE OF BIOLOGICAL INDICATORS TO DETECT (WHICH
MAY TAKE SEVERAL DAYS) FAILURE OF THE AUTOCLAVE. BIOLOGICAL INDICATORS SHOULD BE PLACED IN
THE MOST INACCESSIBLE LOCATION IN THE LOAD AND THEN CULTURED. THEY PROVIDE POSITIVE
ASSURANCE, ALBEIT RETROSPECTIVELY, THAT EACH PACKAGE HAS BEEN SUBJECTED TO PROPER
STERILIZING CONDITIONS.
TOTAL TIME REQUIRED
AUTOCLAVE – 45 TO 50 MIN
CSSD HAS TWO ROOMS STERILE + PACKING ROOM AND WASHING ROOM
AUTO CLAVE SIGNAL LOCK & ETO SIGNAL LOCK USED TO INDICATE THAT MATERIAL IS
STERILISED
STERILE SUPPLIES AND PACKS AND CONTAMINATED ARTICLES SHOULD NEVER BE CARRIED
ON THE SAME TROLLEY OR BY THE SAME STAFF.