Technical Presentation On Condensate Classification
Technical Presentation On Condensate Classification
PROJECT: PHASE 3
• BACKGROUND
• PHASES 1 & 2: OVERVIEW
• PHASE 3: OBJECTIVES & SCOPE
WORK
• PHASE 3: CLASSIFICATION
METHODOLOGY
• PHASE 3: WORK PLAN
• PHASE 3: STATUS UPDATE
• CHALLENGES
BACKGROUND
INTRODUCTION
• The OPEC Representative from the Office of the
Honourable Minister of Petroleum Resources (MPR)
plans to get all NGLs and Gas Condensate from the
Niger Delta Basin and the Deep Offshore Classified
according to OPEC resolution LXXXIV286.
OBJECTIVES
To classify Nigerian Natural Gas Liquids (NGLs)
and Gas condensate from all reservoirs in
compliance with OPEC classification criteria.
Oil
66%
NOTE:
• Agbami and Akpo were left as originally classified by the
Operators.
PHASE 2: OVERVIEW
BACKGROUND
• Commencement & Completion Date: February,
2018 - July, 2019
• Joint Project Team: NNPC R&D (Now NOFS)
and DPR (Now NUPRC)
• Technical Consultant: HPO Global.
OBJECTIVES
To carry out atmospheric sampling of identified
“Borderline” fluids.
To subject all sampled “Borderline” fluid samples to
batch distillation test (ASTM D86) based on OPEC
criteria.
PHASE 2: SUMMARY OF RESERVOIRS
CLASSIFICATION AFTER ASTM D86 TEST
CLASSIFICATION
Borderline Borderline Unsampled Borderline
Gas
Reservoirs reservoirs Borderline fluids Oil
Condensate
from Phase 1 sampled reservoirs Analysed
395 217 178 217 57 160
No. of
S/No. Fluid Type %
Reservoirs
1 Gas Condensate 57 26
2 Oil 160 74
PHASE 2: VOLUME OF CONDENSATE AFTER
ASTM D86 TEST
PHASE 3: OBJECTIVES
EXPERIMENTA
L RESULTS
CCE: Saturation VOLUME
PVT & pressure COMPUTATION
Compositional SEPTEST: API &
Analysis
Results GOR
Fluid OIL
Composition:
C7+
LOWER LIMIT:
API:≤45
GOR:≤5000SCF/BBL
C7+:8% or higher
PHASE 3- WORK PLAN
RESULT FINA
PROJECT LAB INTEGRATI L
FIELD ANALYSI
INITIATION ON & REP
SAMPLIN S
G REPORTIN ORT
G
GAS CONDENSATE
PVT RESULTS DATABASE UPDATE
REVIEW
SAMPLING
HANDLING & JOINT INTEGRATION BY PROJECT TEAM/REVIEW MEETING
SETUP-TEAMS SHIPMENT OF
STORAGE
DPR LETTERS TO FACILITY
OPERATORS SAMPLES
MOBILIZATION TO LOCATIONS
PHASE 3: STATUS
UPDATE
Milestone One: Completed
NOTES
Mobilized to SEPLAT, AGIP, SNEPCO, SPDC and
NPDC locations.
Total reservoir samples collected is 71/90
Plans to re-mobilize to NPDC, AGIP and SPDC
locations to cover the remaining reservoirs.
PHASE 3: STATUS UPDATE
Cont’d
Milestone Four: Completed (45/45) reservoirs
PVT/Compositional analysis of first batch of 40
reservoirs in external laboratory and 5 reservoirs in
NOFS laboratory.
Sample Numbers : OBEN 39L & OBEN 39L Sample Type : Recombined Separator Products
Recombination Parameters:
Wellstream Molar Ratio, mol gas / mol liquid 21.82
Fluid Total Molecular Weight, gm/mol 24.4
(1) Hexatri contanes pl us properti es cal cul ated by summati on of al l composi ti onal data.
Thank You