Modeling Useful Creep Life
Modeling Useful Creep Life
*
G E Dieter, Mechanical Metallurgy, Tata McGraw Hill
Application of the Larson Miller parameter
approach
• Below is the stress vs LMP plot for pure Ti. What will be the LMP value
for an applied stress of 150 MPa. What is the time to failure, if the test
temperature is 400 C and the constant C is 20?
ln t = (LMP / T) – C
T = 300 °C = 573 K
ln t = (13200 / 573) – 15
ln t = 23.03-15 = 8.03