Critical Piping

The document discusses the design of critical piping and drainage systems for steam turbines. Any pipe connecting to the turbine is a potential source of water ingress. The design aims to detect, isolate, and dispose of any water while ensuring no single failure allows water into the turbine. Main steam, reheat, cold reheat and bypass piping systems are described, including drain locations, valves and routing to flash tanks to minimize water entering the turbine.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
382 views49 pages

Critical Piping

The document discusses the design of critical piping and drainage systems for steam turbines. Any pipe connecting to the turbine is a potential source of water ingress. The design aims to detect, isolate, and dispose of any water while ensuring no single failure allows water into the turbine. Main steam, reheat, cold reheat and bypass piping systems are described, including drain locations, valves and routing to flash tanks to minimize water entering the turbine.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 49

WORKS HOP ON CRITICAL PIPING &

AS S OCIATED S YS TEMS
(7–8 TH AUGUS T’ 2002, AT TS -HQ, KRIBHCO BHAWAN, NOIDA)

PRES ENTATION
ON

CRITICAL PIPING DRAINAGE


S YS TEM
BY
VIPIN GUPTA, DGM, PEM
1
Bharat Heavy Electricals Limited
ANY PIPE CONNECTION TO THE TURBINE IS A
POTENTIAL SOURCE OF WATER EITHER BY INDUCTION
FROM EXTERNAL EQUIPMENT OR BY ACCUMULATION
OF CONDENSED STEAM

2
DESIGN BASIS

• ASME TDP – 1

• RECORD NOTES OF DISCUSSION HELD AT TS-HQ,


N.DELHI ON 12.09.91 REGARDING DRAINS SYSTEM

• SPECIFIC CUSTOMER REQUIREMENTS

3
DESIGN CRITERIA

• DETECTION OF THE PRESENCE OF WATER

• ISOLATION OF THE WATER BY MANUAL OR


PREFERABLY AUTOMATIC MEANS
 
• DISPOSAL OF THE WATER BY MANUAL OR
PREFERABLY AUTOMATIC MEANS
 
• NO SINGLE FAILURE OF EQUIPMENT SHOULD RESULT
IN WATER ENTERING THE TURBINE

4
MAIN STEAM PIPING

5
MAIN STEAM PIPING

• MS PIPING DRAINS UPTO TURBINE VALVES ARE LED TO


ATMOSPHERE

• DRAINS DOWNSTREAM OF TURBINE STOP VALVES ARE LED TO


CONDENSER
 
• START-UP DRAIN IS PROVIDED AT THE UPSTREAM OF BOILER
STOP VALVE
 
• MS STRAINER IS THE LOWEST POINT AND FORMS THE DRAIN
POINT
 
• BEFORE SEAT DRAIN IS CASCADED BACK TO THE MAIN STEAM
LINE
 
• DURING START-UP MS STRAINER / LINE DRAINS ARE OPEN TO
ATMOSPHERE
  CONTD.
6
MAIN STEAM PIPING

 
• AUTOMATIC CLOSURE OF MS STRAINER & LINE DRAINS
 
• SEPARATE ATMOSPHERIC FLASH TANK (UFT) IS PROVIDED IN TG
AREA TO RECEIVE MS DRAINS / HP BYPASS DRAINS TO MINIMIZE
ROUTING PROBLEM
 
• DRAINAGE SYSTEM AS DESCRIBED HAS BEEN ADOPTED IN
VARIOUS 210 MW / 250 MW / 500 MW PROJECTS LIKE DADRI,
UNCHAHAR, BAKRESWAR, DAHANU, SURATGARH, KOTHAGUDEM,
SIMHADRI ETC.

7
START-UP DRAIN UPSTREAM OF
BOILER STOP VALVE

8
MAIN STEAM LINE DRAINS
(TYPICAL FOR ONE LEG)

HPT

(BEFORE
SEAT
DRAIN)
TO TURBINE
FLASH BOX
(MAL SYSTEM)
(AFTER SEAT DRAIN)
MAIN STEAM

TO UNIT FLASH TANK


(L.O.)
(MS STRAINER DRAIN)

9
MAIN STEAM STRAINER DRAIN

10
HOT REHEAT PIPING

11
HOT REHEAT PIPING

• DRAINAGE SYSTEM IS SIMILAR TO THAT OF MAIN


STEAM EXCEPT THAT PRIOR TO STARTING THE
TURBINE THE HOT REHEAT PIPING WILL BE AT
CONDENSER PRESSURE, HENCE HOT REHEAT PIPING
DRAINS ARE TO BE LED TO CONDENSER

• HRH DRAIN VALVES ARE OPEN BEFORE START OF


VACUUM PULLING

• AUTOMATIC CLOSURE OF HRH STRAINER & LINE


DRAINS

• ADDITIONALLY MANUAL DRAIN IS PROVIDED AT THE


UPSTREAM OF RH ISOLATING DEVICE TO FACILITATE
DRAINING OF PIPING AFTER HYDRO TEST OF RH
SECTIONS
12
HRH RH ISOLATING DEVICE

13
HRH LINE DRAINS
(TYPICAL FOR ONE LEG )

IPT

(BEFORE
SEAT TO TURBINE
DRAIN) FLASH BOX
(MAL SYSTEM)

(AFTER SEAT DRAIN)


HOT REHEAT

TO CONDENSER
FLASH TANK
(L.O.)
(HRH STRAINER DRAIN)

14
HRH DRAIN BETWEEN IPT & VALVE

15
HRH STRAINER DRAIN

16
COLD REHEAT PIPING

17
COLD REHEAT PIPING

• THE POTENTIAL SOURCE OF WATER INGRESS INTO CRH PIPE


ARE:
 REHEATER SPRAY
 HP BYPASS SPRAY
 TOP HEATER EXTRACTION PIPING FROM HP EXHAUST

• DESIGN OF DRAINAGE SYSTEM TO REMOVE THE ENTIRE


WATER THAT CAN ENTER INTO CRH LINE IS IMPRACTICAL

• SYSTEM IS DESIGNED TO PROVIDE SIGNAL TO ENABLE


OPERATOR TO TAKE CORRECTIVE ACTION TO PREVENT
WATER INFLOW

• CRH PIPING DRAINS ARE LED TO CONDENSER AS IT COMES


UNDER VACUUM DURING START-UP

CONTD.
18
COLD REHEAT PIPING

• PIPING DOWNSTREAM OF CRH NRV FORMS LOWEST POINT IN


THE CRH LINE

• ADDITIONALLY DRAIN IS PROVIDED BETWEEN HP TURBINE


EXHAUST & CRH NRV

• A MANUAL DRAIN IS ALSO PROVIDED AT THE DOWNSTREAM


OF RH ISOLATING DEVICE TO FACILITATE DRAINING OF PIPING
AFTER HYDRO TEST OF RH SECTIONS

19
CRH RH ISOLATING DEVICE

20
COLD REHEAT LINE DRAINS

HPT

HH
A
DRAIN POT TO TURBINE
H A FLASH BOX
LS (L.O.) (MAL SYSTEM)
LS

(L.O.)

TO CONDENSER
FLASH TANK

21
CRH PIPING DRAIN BETWEEN HPT
EXHAUST & NRV

22
CRH PIPING DRAINS

23
CRH PIPING DRAIN POT

• DRAIN POT OF 6 INCH DIA IS PROVIDED IN 210 MW / 250 MW &


12 INCH DIA IN 500 MW AT THE EACH LOW POINT

• TWO LEVEL SWITCHES ARE INSTALLED ON THE DRAIN POT


FOR SENSING OF PRESENCE OF CONDENSATE IN THE DRAIN
POT AND EFFICIENT EVACUATION OF THE SAME

• LEVEL SWITCH AT HIGH LEVEL SHALL INITIATE FULL OPENING


OF THE DRAIN VALVE AS WELL AS PROVIDE AN ALARM IN
CONTROL ROOM

• LEVEL SWITCH AT HIGH HIGH LEVEL SHALL INITIATE AN


ALARM AND REPEAT COMMAND FOR OPENING DRAIN VALVE

CONTD.
24
CRH PIPING DRAIN POT

• HIGH HIGH LEVEL IS A WARNING TO THE OPERATOR TO


INVESTIGATE & ISOLATE THE SOURCE OF WATER INGRESS

• BEFORE START OF VACUUM PULLING CRH DRAINS ARE OPEN


TO CONDENSER AND OPERATOR TO ENSURE NO ALARM
CONDITION ( CW PUMP & CEP ARE RUNNING)

• SPRAY IS ENVISAGED IN FLASH TANK TO COOL DRAINS

• CLOSING OF CRH DRAIN VALVE IS REMOTE MANUAL

25
CRH DRAIN POT ARRANGEMENT

26
HP BYPASS PIPING

27
HP BYPASS PIPING

• HP BYPASS WARM-UP & DRAIN ARRANGEMENT HAS BEEN


ADOPTED IN LINE WITH DELIBERATIONS DTD. 20-21ST FEB. ‘
1998 AT TRICHY

• HP BYPASS PIPING LAYOUT IS SUCH THAT ENTIRE PIPING IS


SELF DRAINABLE TOWARDS MAIN STEAM / COLD REHEAT
PIPING

• WARM-UP TAPPING IS PROVIDED CLOSE TO THE BYPASS


VALVE FROM BOTTOM OF THE PIPING

• WARMING-UP LINE IS CONNECTED TO CRH LINE MINIMUM 5M


AWAY FROM TEMPERATURE TAPPING POINTS

• START-UP DRAIN IS PROVIDED ON THE WARM-UP LINE AND IS


LED TO ATMOSPHERE CONTD.
28
HP BYPASS PIPING

• START-UP DRAIN OPENS PRIOR TO STARTING THE UNIT AND


CLOSES WHEN HP BYPASS VALVE IS TAKEN INTO SERVICE

• TEMPERATURE MEASUREMENT SHALL BE PROVIDED AT HP


BYPASS VALVE INLET

• HP BYPASS VALVE TO BE LOCATED ABOVE THE MAIN STEAM


& CRH PIPING

• WARMING-UP LINE TO DOWNSTREAM OF MS STRAINER IS NOT


PREFERRED AT IT WOULD LEAD TO UNSTRAINED STEAM TO
TURBINE

29
HP BYPASS WARMING-UP SCHEME

HP BYPASS
VALVE
TE

TE TE

250 mm 5 M (min)

WARM-UP LINE
(LO)

MAIN STEAM LINE COLD REHEAT LINE


START-UP DRAIN

TO UFT

30
HP BYPASS WARM-UP PIPING

31
LP BYPASS PIPING

32
LP BYPASS WARM-UP PIPING

33
LP BYPASS WARM UP PIPING

34
LP BYPASS PIPING

• IN EARLIER 210MW SETS AN ISOLATING VALVE WAS


ENVISAGED IN LP BYPASS WARM-UP SCHEME

• THE PURPOSE OF ISOLATING VALVE IS TO ISOLATE WARM-UP


LINE DURING INITIAL COLD START-UP

• THIS VALVE HAS TO BE KEPT OPEN IN ALL OTHER MODES OF


OPERATION

• BASED ON THE SITE FEEDBACK AN ANALYSIS WAS DONE & IT


WAS OBSERVED THAT OPERATION OF ISOLATING VALVE WAS
NOT PROPER AND WAS USUALLY LEFT CLOSED WHICH LEAD
TO PROBLEMS WITH LP BYPASS SYSTEM

• FROM DADRI 210MW TPS ONWARDS THIS ISOLATING VALVE


HAS BEEN DISPENSED WITH CONTD.
35
LP BYPASS PIPING

• IN 500MW PROJECTS ALSO THERE IS NO ISOLATING VALVE IN


THE WARM-UP LINE

• THIS HAS ENHANCED THE SYSTEM RELIABILITY AND EASE IN


OPERATION

• LP BYPASS LOOP PIPING DRAINS CAN BE CASCADED BACK


TO HRH PIPING (BETWEEN TURBINE & STRAINER) AT AN
LOWER ELEVATION OTHERWISE DRAIN CAN BE LED TO
CONDENSER

• DRAIN ON WARMUP LINE IS PROVIDED CLOSE TO VALVE TO


ENSURE WARMING UP

CONTD.
36
LP BYPASS PIPING

• BEFORE PULLING VACUUM IN THE CONDENSER OPEN ABOVE


DRAINS TO CONDENSER

• ONCE LP BYPASS VALVE IS TAKEN INTO OPERATION THESE


DRAIN VALVES CAN BE CLOSED

37
LP BYPASS WARMING UP SCHEME
FOR 210 MW UNITS

HRH LINE
HRH
STRAINER
CONTROL VALVE

TO CONDENSER

Nb 450
STOP VALVE
LP BYPASS
MAIN LINE

TO TURBINE
TO CONDENSER
VIA FLASH TANK
Nb 50 LP BYPASS
WARM-UP LINE

WARM-UP STEAM FLOW IN COLD CONDITION


WARM-UP STEAM FLOW DURING NORMAL RUNNING OF TURBINE

38
LP BYPASS WARMING UP SCHEME
FOR 500 MW UNITS

HRH LINE
HRH
STRAINER

Nb 650
STOP VALVE
LP BYPASS
MAIN LINE

TO CONDENSER
TO TURBINE TO VIA FLASH TANK
CONDENSER
CONTROL VALVE

Nb 50 LP BYPASS
WARM-UP LINE

WARM-UP STEAM FLOW IN COLD CONDITION


WARM-UP STEAM FLOW DURING NORMAL RUNNING OF TURBINE

39
OPERATING MODES

• COLD START-UP

DRAINS SHALL BE OPERATED AS DESCRIBED EARLIER

• HOT START-UP

DURING TURBINE TRIPPED / BOILER TRIPPED CONDITION,


OPEN AND CLOSE DRAINS AS IN COLD START-UP. MS
STRAINER DRAINS ARE TO BE CLOSED AS SOON AS 50°COF
SUPERHEAT IS ACHIEVED AND BYPASS IS ESTABLISHED.

DURING TURBINE TRIPPED / BOILER IN SERVICE WITH


HP/LP BYPASS CONDITION NO DRAINS TO BE OPENED

40
NTPC SPECIFIC REQUIREMENTS

FOLLOWING ARE ADDITIONAL FEATURES PROVIDED IN NTPC


PROJECTS AS PER THE CONTRACTUAL REQUIREMENT:

• ANGLE VALVES INSTEAD OF GLOBE VALVES IN DRAIN LINES

• NTPC SPECN. CALLS FOR TWO DRAINS FOR EACH DRAIN


POINT I.E. ONE AS NORMAL DRAIN TO DRAIN FLASH TANK AND
THE OTHER AS ALTERNATE DRAIN TO ATMOSPHERIC FLASH
TANK. AFTER DELIBERATIONS ALTERNATE PATH ARE
PROVIDED FOR MAIN STEAM DRAINS & HOT REHEAT DRAINS
ONLY

• CLEAN OUT VALVES FOR DRIP POTS

41
ANGLE VALVE DRAIN ARRANGEMENT

42
FLASH TANKS SPRAY SYSTEM

FOR COOLING OF INCOMING HOT DRAINS FOLLOWING SPRAYS


ARE ENVISAGED IN THE FLASH TANKS:

• CONDENSATE SPRAY FROM CEP DISCHARGE TO CONDENSER


FLASH TANK THROUGH TEMPERATURE REGULATED ON / OFF
TYPE CONTROL VALVE

• CONTINUOUS SPRAY THROUGH A MANUAL REGULATING


VALVE & RESTRICTION ORIFICE FROM SERVICE WATER
SYSTEM TO UNIT FLASH TANK

• CONTINUOUS SPRAY THROUGH A RESTRICTION ORIFICE


FROM CEP DISCHARGE VALVE GLAND SEALING HEADER TO HP
DRAIN FLASH TANK

43
UNIT FLASH TANK ARRANGEMENT (TYP)

HPBP WARM-UP MS STRAINER


LINE DRAINS (TYP) DRAINS (TYP)

( LO ) ( LO )
SPRAY WATER
FROM SERVICE
WATER SYSTEM

UNIT
FLASH
TANK

3M

TO DRAIN
TRENCH

44
GENERAL RECOMMENDATIONS

• DESIGN , CONTROL AND OPERATION OF ALL SYSTEM THAT


HAVE A POTENTIAL FOR ALLOWING WATER TO THE TURBINE
SHALL PREVENT ANY UNUSUAL ACCUMULATION

• DRAINS SHALL BE INSTALLED AT EVERY LOW POINT WITH


ADEQUATE MEANS (MANUAL / AUTOMATIC) TO DISPOSE OFF
THE CONDENSATE COLLECTED

• DRAIN LINE SIZE SHALL BE SUFFICIENT TO PREVENT RISK OF


PLUGGING BY FOREIGN MATERIAL. NORMALLY DRAIN LINE SIZE
IS 2 INCH

• ALL DRAIN LINES SHALL PREFERABLY BE RUN INDIVIDUALLY


AND HAVE CONTINUOUS SLOPE TOWARDS THE DISPOSAL POINT

CONTD.
45
GENERAL RECOMMENDATIONS

• HIGH PRESSURE DRAINS SHALL BE PROVIDED WITH TWO


VALVES IN SERIES , UPSTREAM LOCKED OPEN VALVE &
DOWNSTREAM MOTORIZED VALVE. LOW PRESSURE DRAINS
SHALL BE PROVIDED WITH MOTORIZED VALVE

• ALL MOTORIZED DRAINS SHALL HAVE FACILITY TO OPERATE


FROM UNIT CONTROL ROOM WITH OPEN / CLOSE POSITION
INDICATION

• OPERATOR TO ENSURE THAT ALL THE MOTORISED DRAIN


VALVES SHALL BE CLOSED IMMEDIATELY ON ATTAINMENT OF
10% BLOCK LOAD ON TURBINE

• INSTALLATION LEVELS OF MS STRAINER. HRH STRAINER , CRH


NRV ETC SHALL BE SUCH THAT DRAIN CAN BE LED WITH
CONTINUOUS PROPER SLOPE TO THE TERMINAL POINT
CONTD.
46
GENERAL RECOMMENDATIONS

• ALTERNATE PATH SHOULD BE AVOIDED AS IT BECOMES


SOURCE OF AIR INGRESS. ALSO AT SOME SITES ITS MAL-
OPERATION RESULTED SUCKING OF WATER FROM
ATMOSPHERIC TANK INTO THE MAIN PIPING LEADING TO
SEVERE PROBLEMS

• DRAINS TO MANIFOLD SHALL BE GROUPED IN


APPROXIMATELY SAME PRESSURE RANGES OTHERWISE
DRAINS SHALL BE ARRANGED IN A DECREASING ORDER OF
THE PRESSURE

• DRAIN LINES TO THE MANIFOLD SHALL BE MOUNTED AT 450


TO THE MANIFOLD AXIAL CENTRE LINE WITH THE DRAIN LINE
DISCHARGE POINTING TOWARDS THE DISPOSAL POINT
CONTD.
47
GENERAL RECOMMENDATIONS

• DRAIN SHALL BE PREFERABLY TAPPED THROUGH A DRIP POT

• LOOPS REQUIRED FOR FLEXIBILITY SHALL BE IN THE PLANE OF


THE SLOPE

• LOOP DRAINS CAN BE CASCADED BACK TO THE MAIN PIPING BY


GRAVITY AT A LOWER ELEVATION

• OPERATION OF DRAIN VALVE, PLUGGING OF DRAIN LINES AND


HEALTHINESS OF INSTRUMENTS SHALL BE PERIODICALLY
CHECKED

• LEVEL ACTUATED MECHANISM SHALL BE TESTED AT INTERVALS


TO ENSURE THEIR PROPER FUNCTIONING

• DRIP POTS, TRAPS & ORIFICES FOR ALL DRAIN LINES SHALL BE
REGULARLY CLEANED
48