Introduction To The Configuration ZXCTN6150

The system requires the following: 1. It must be small and install inside BTS racks. 2. It needs 1GE port but with less than 1GE bandwidth. 3. It requires at least 4 Fast Ethernet ports. 4. It needs STM-1 optical and electrical ports. 5. It requires at least 16 E1 ports. 6. All links between sites must have protection.

Uploaded by

Davood
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
223 views

Introduction To The Configuration ZXCTN6150

The system requires the following: 1. It must be small and install inside BTS racks. 2. It needs 1GE port but with less than 1GE bandwidth. 3. It requires at least 4 Fast Ethernet ports. 4. It needs STM-1 optical and electrical ports. 5. It requires at least 16 E1 ports. 6. All links between sites must have protection.

Uploaded by

Davood
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 2

Requirements

1- System size should be small and will install inside BTS racks.
2- System should have 1GE port. Port should be 1GE but bandwidth is less than GE.
3- System should have at least 4 Fast Ethernet ports.
4- System should have STM-1 optical and electrical ports.
5- System should have at least 16 E1.
6- All links between sites should have protection.
Configuration for ZXCTN 6150
Panel
ZXCTN 6150  

STM-1×4(O) STM-1×4(O)   PW2D

E1×16-75 STM-1×4(O)   Blank(for


POWER) FAN
   
 
FE×8(E)   SME  
GECH×4(OE) Blank  
 

Notes:
Board Description The system I configured is a PTN&IP RAN system, if
E1×16-75 16 75Ω TDM E1 Interfaces only for IP traffic, IP RAN is better than PTN.
FE×8(E) 8 FE Electrical Interfaces The blank slot(marked green) is a universal slot, can
  4 Optical&Electrical Combo Interfaces be used for both service board and main control board.
GECH×4(OE)
STM-1×4(O) 4 STM-1 Optical Interfaces For the STM-1 board, each can provide 4 optical
Control Board , 1+1 Protection interfaces; but because the volume of electrical module
is a little big, when use electrical module 1 board can
1 External Warning Interfaces ( RJ45 , 8
provide 2 electrical STM-1 interfaces.
Warnings )
  SME 1 Qx Interfaces ( RJ45 ) So for the (4 optical + 4 electrical) STM-1 interfaces
1 LCT Interfaces ( RJ45 ) requirement, 3 STM-1 boards will be needed.
1 BITS Interface The LOM includes all the modules and accessories.
1 GPS Interface
PW2D (-48V~-60V),Support 1+1 Protection