The document provides information about the 132 kV GSS Mahaveer Nagar substation in Kota, Rajasthan. [1] It discusses the key equipment used at the substation including power transformers, instrument transformers, lightning arresters, isolators, circuit breakers, and relays. [2] The substation receives incoming 132 kV supply from two other substations and steps it down to 33 kV and 11 kV for distribution. [3] It provides a single line diagram and layout showing the arrangement of major equipment.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
100%(1)100% found this document useful (1 vote)
48 views
Substation
The document provides information about the 132 kV GSS Mahaveer Nagar substation in Kota, Rajasthan. [1] It discusses the key equipment used at the substation including power transformers, instrument transformers, lightning arresters, isolators, circuit breakers, and relays. [2] The substation receives incoming 132 kV supply from two other substations and steps it down to 33 kV and 11 kV for distribution. [3] It provides a single line diagram and layout showing the arrangement of major equipment.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 26
A
Training Presentation on 132 kV GSS MAHAVEER NAGAR KOTA
Submitted by: Submitted to:
Naziya Kosar Dr. DK Sambhariya 20EUCEEO56 Electrical Engineering Associate professor Elect. eng. department RTU Kota CONTENT 1. Introduction 8. Insulator 2. Power Transformer 9. Isolator 3. Instrument Transformer 10. Circuit Breaker i. Current Transformer 11. Relay ii. Potential Transformer 12. Battery 4. Lightning Arrestor 13. Single LIne Diagram 5. Wave Trap 14. Layout of Substation 6. Bus Bar 7. Bus Coupler SUBSTATION • An assembly of apparatus used to change some characteristics of electric supply. • Generally transform voltage from high to low ar vice versa. • Between the generating station and consumer, different substations operate at different levels. GSS MAHAVEER NAGAR KOTA • Established on 13 march, 1994. • Total capacity of the GSS is around 100 MVA. • The incoming 132 kV supply is stepped down to 33kV and 11kV. • Incoming feeder fed 132kV supply from GSS Sakatpura and GSS Ranpur. INCOMING FEEDERS: OUTGOING FEEDRES:
• 220/132kV Sakatpura Kota • 33 KV TALWANDI
• 220/132kV Ranpur Kota • 33 KV BASANT VIHAR • 33 KV DADABARI • 33 KV RIMDC • 33 KV RANPUR • 33 KV PHED • 33 KV INDRA VIHAR • 132 KV R.K. PURAM • 11 KV RANGBARI • 11 KV MEDICAL COLLEGE • 11 KV BALAJI NAGAR POWER TRANSFORMER • Static device to transform electrical energy. • Transformer used in substations are of high ratings. • Used in transmission and distribution system for step up or step down the AC voltage. • Two tranformers are assembled in GSS mahaveer nagar for step down the voltage. • Ratings of power transformer: 133/33kV star connected 40/50MVA COOLING FOR POWER TRANSFORMER • Usually two types of cooling is available: i. Oil coooling - a conservating tank is mounted at the top of transformer. ii. Air Cooling - Fans are mounted for at both side of transformer.
At faulty condition the
explosion vent are used to release the oil pressure. INSTRUMENT TRANSFORMER • Combination of measuring instrument and step down transformer. • Used to measure electrical quantities such as voltage, current, power factor etc. • Extend the range of measuremet. • Two types of instrument transformer: i. Current Transformer (CT) ii. Potential Transformer(PT) CURRENT TRANSFORMER • Step down the current for mesurement purpose. • Used for current limiting to control, protect and operate relays. • Large number of secondary turns and few number of primary turns POTENTIAL TRANSFORMER • They are step down transformers. • Measures high alternating voltage. • CVT: • capacitor divider with it associated electromagnetic unit. • The divider provides an accurate proportioned voltage, while the magnetic unit transform the voltage. LIGHTNING ARRESTER • Protect from high voltage surges. • Diverts the abnormal high voltage to the ground without affecting the continuity of supply. • Connected between phase and ground terminal. WAVE TRAP • Used to block communication signals. • It act as filtering cum protective device. • Allows only 50Hz signals to pass through it. BUSBAR • Solid metal bars which carry current. • Consist the number of lines connected to it which have same voltage and frequency, • Genrally made up of copper or aluminium. • Two type of bus bar: • Main Bus • Auxillary Bus BUS COUPLER • Used to couple one bus to other without any interruption in power supply • In case of overload, it transfer load between buses. INSULATOR • Materials which do not allow flow of electricity through them. • Give support to the overhead line conductors and prevent the current flow towards earth. • Post, shackel and suspension type insulator are used in 132kV substation. ISOLATORS • Manually operated mechanical switches. • Isolate the faulty section of substation. • Operated at off load condition only. • Also called as disconnector or disconnecting switch. CIRCUIT BREAKER • Electric switch used for protecting the equipments from the damage caused by overcurrent, overvoltage or short circuit. • Interrupt current flow after realay detects a fault. • Operate in on load conditions. • Two types of circuit breaker are used in GSS mahaveer Nagar: 1. Vaccum Circuit Breaker 2. SF6 Circuit Breaker VACUUM CIRCUIT BREAKER SF6 CIRCUIT BREAKER • Arc quenching takes place in • Uses pressurized SF6 gas to vacuum medium. extinguish arc. • Used for low voltages. • Used for high voltage • Vacuum offers highest insulating applications. strength. RELAYS • Sensing gadgets used for sensing fault in substation. • Used to trigger CBs and other swtches in substation. • It senses abnormal conditions and give an alarm. • Two types of relay are used: 1. Electromagnetic relay 2. Dgital relay Electromagnetic Relay Digital Relay • Produce a magnetic field by an • Uses microprossesor analyze electromagnetic coil when relay power system voltages, current detects a fault. or other quantities for fault • This magnetic field is used for the detection. opening and closing of the • High speed, accuracy and switch. flexibility. BATTERIES • Battery bank is available for supplying power to relay system, control circuitry and som other operations which requires dc supply. • 55 batteries each of 2 volts are available here. SINGLE LINE DIAGRAM LAYOUT OF SUBSTATION
3 4 5 6 1 2 7
1. Lightning Arrester 5. Circuit Breaker
2. CVT 6. Current transformer 3. Wave Trap 7. Power Transformer 4. Isolator THANKYOU