Data Plate Containers Cosalt

The document discusses standards and legislation for offshore containers. It outlines British and DNV standards, including requirements for visual inspections and load testing of containers on a periodic basis, such as every 6 months to 5 years depending on the standard. It also provides an example of data that would be included on an inspection plate for a particular container.
Copyright
© © All Rights Reserved
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
48 views

Data Plate Containers Cosalt

The document discusses standards and legislation for offshore containers. It outlines British and DNV standards, including requirements for visual inspections and load testing of containers on a periodic basis, such as every 6 months to 5 years depending on the standard. It also provides an example of data that would be included on an inspection plate for a particular container.
Copyright
© © All Rights Reserved
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 12

Container Standards & Legislation

The standards applicable to containers for offshore use are:

BS 7072 : 1989
British Standard Code of practice for
Inspection and repair of offshore containers. (WITHDRAWN)

BS EN 12079: 1 : 2006
British Standard Code of Practice for Offshore containers – Design, construction, testing,
inspection and marking.

Det Norske Veritas Classification AS


Standard for Certification No DNV 2.7-1. Offshore Containers April 2006 .
Examination and Test definitions

suffix to be marked on plate. T


= Lifting test ( proof load test)

suffix to be marked on plate. V


= Thorough visual examination

suffix to be marked on plate. VN


= Non-destructive examination of pad eyes.
Examination and Test schedule

BS 7072 : 1989

T Lifting or proof load test 2 x gross weight :

• Before being used for the first time.

• At intervals not exceeding 24 months.

• After any substantial repair or alteration.


Examination and Test schedule

BS 7072 : 1989

V thorough visual examination :

• Before being used for the first time.

• At intervals not exceeding 6 months.

• At intervals not exceeding 12 months.

• At intervals not exceeding 24 months.

• After any substantial repair or alteration.


Examination and Test schedule
BS 7072 : 1989

VN thorough visual examination and Non-destructive examination of lift


points :

• Before being used for the first time.

• At intervals not exceeding 6 months.


(at the discretion of the competent person)

• At intervals not exceeding 12 months.

• At intervals not exceeding 24 months.

• After any substantial repair or alteration.


Examination and Test schedule

BS EN 12079: 1 : 2006

T Lifting or proof load test 2.5 x gross weight :

• Before being used for the first time.

• At intervals not exceeding 12 months.


(At the discretion of the inspection body)

• At intervals not exceeding 60 months (5 years).


(At the discretion of the inspection body)

• After any substantial repair or alteration.


Examination and Test schedule

BS EN 12079: 1 : 2006

V thorough visual examination :

• Before being used for the first time.

• At intervals not exceeding 12 months.

• At intervals not exceeding 60 months (5years).

• After any substantial repair or alteration.


Examination and Test schedule

BS EN 12079: 1 : 2006

VN thorough visual examination and Non-destructive examination of lift


points :

• Before being used for the first time.

• At intervals not exceeding 12 months.


( at the discretion of the inspection body )

• At intervals not exceeding 60 months (5 years).

• After any substantial repair or alteration.


Examination and Test schedule

DNV 2.7-1 : 1995 & 2006

T Lifting or proof load test 2.5 x gross weight :

• Before being used for the first time.

• At intervals not exceeding 12 months.


( At the discretion of the inspector )

• After any substantial repair or alteration.


Examination and Test schedule

DNV 2.7-1 : 1995 & 2006

V thorough visual examination :

• Before being used for the first time.

• At intervals not exceeding 12 months.

• After any substantial repair or alteration.


Examination and Test schedule

DNV 2.7-1 : 1995 & 2006

VN thorough visual examination and Non-destructive examination of lift


points :

• Before being used for the first time.

• At intervals not exceeding 12 months.


( at the discretion of the inspector )

• After any substantial repair or alteration.


DATA PLATE
Cosalt International Limited
Aberdeen 826662
Offshore Inspection Test Record
Owners Name____HALLIBURTON SUBSEA_______
Identification No_____HSS 1234_________________
Date of Manufacture__12/11/98__________________
Tare Weight___________ 2________________________tonne
S.W.L./Payload_________ 4________________________tonne
Max. Gross Weight______6________________________tonne

Date of last Test / Examination


12/1/00 T 13/2/02 T
14/7/00 V
18/1/01 VN
11/7/01 V