0% found this document useful (0 votes)
36 views

02 - EMC Pre Compliance Tests

EMC Pre Compliance Tests
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views

02 - EMC Pre Compliance Tests

EMC Pre Compliance Tests
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 10

V1.

0 EMC Pre-compliance tests


Definition:
• EMC tests performed prior to submitting the product to an EMC test-lab.
• EMC tests performed to improve a device after failing type approval
• Often performed in the design labs of companies that develop and manufacture
electronic products.
• Often performed with equipment, lab space, and budget constraints.
• Keep the test setup as basic as feasible while also closely mimicking a standard
compliant setup as possible.

Target:
New products should be tested for EMC performance during the design process to
prevent failing type approval, which would result in a costly redesign, a delayed
manufacturing ramp up, and a delayed market entry. Pre-compliance testing must
result in successful type approval on the first pass.
V1.0
Pre-compliance testing constraints
Budget
• affordable spectrum analyzers with EMI option (Rigol, R&S, Siglent) instead of
measurement receivers
• Affordable EMC test software (Tekbox EMCview)
• Affordable transducers (Tekbox LISN, current probes, antennas, CDN,…)

Lab space
• Shielded tents or shielded bags as replacement of shielded chambers
• Lab or open area instead of anechoic chamber
• Space requirements for wooden measurement table and groundplanes

Complexity:
• Non standard compliant setup
• Simplified setup
• Effects on measurement results
V1.0
Which tests?

Most frequent failures


• Conducted emissions
• Conducted immunity
• Radiated emissions
• Radiated immunity

Tests with low level of difficulty


• Conducted emissions on supply lines
• Conducted emissions on control and data lines
• Conducted immunity on supply lines
• Conducted immunity on control and data lines

Tests with medium level of difficulty


• Radiated immunity

Tests with high level of difficulty


• Radiated emissions
V1.0
Pre-compliance test setup -
how accurate can it be ?

Conducted emission tests


• Excellent correlation with test-house reports
• With careful setup, pretty much spot on

Conducted immunity tests


• Excellent correlation with test-house results

Radiated immunity tests


• Good correlation with test-house results

Radiated emission tests


• Requires effort and experience, to achieve a satisfying correlation with test-house
reports

https://www.youtube.com/watch?v=KHxbk4eToXs
V1.0
Conducted emission tests

Conducted emission tests


• The majority of conducted emission tests are carried out using a LISN
• 50µH LISN predominantly for products intended for use in industrial or domestic environment
• 5µH LISN predominantly for automotive products

Simplified setup of a 50µH LISN

Refer to the relevant standard for the correct setup

Other transducers
• RF Current monitoring probes
• CDNE´s
• Voltage probes
V1.0
Conducted immunity tests

Conducted immunity tests


• The majority of conducted emission tests are carried out CDN´s

Simplified setup

Refer to the relevant standard for the correct setup

Other transducers
• Bulk current injection probes
• Electromagnetic clamp
• Tubular wave coupler
V1.0
Radiated emission tests

Radiated emission tests


• The majority of radiated emission tests are carried out with antennas in the far
field and set up in an anechoic chamber

Simplified setup

Refer to the relevant standard for the correct setup


Other transducers
• GTEM-cell
• Stripline
• Large Loop Antenna
V1.0
Radiated immunity tests

Radiated immunity tests


• The majority of radiated immunity tests are carried out with antennas in the far
field and set up in an anechoic chamber

Simplified setup

Refer to the relevant standard for the correct setup


Other transducers
• GTEM-cell
• Stripline
V1.0
Debugging of EMC issues

Use near-field probes to identify the location of radiated emissions or


susceptibility to electromagnetic radiation

Radiated emission

Radiated immunity
Further information on www.tekbox.com

You might also like