SCAR Ref Number :2024-00582 : 29/07/24
Problem: Degassing equipment /Stirrer was not Cleaned, dried potting material observed on stirrer cover.
1. Why Degassing equipment cover not cleaned?
Degassing equipment has attached with motor & Fixture accessories which is not able to separate and entire setup will be replaced once in six month.
2. Why Degassing cover not replaced ?
No definition of replacing frequency of degassing Cover in cleaning Procedure
3. Why cleaning procedure not addressed replacement frequency?
Cleaning procedure not covered about degassing equipment cover cleaning & replacement related requirement
4. Add another question here if applicable?
Because…
5. Add another question here if applicable?
Because… Root Cause: Potting Operator not aware the cleaning of Degassing equipment cover cleaning & Frequency of the replacing the degassing equipment top cover not defined .