5 Why Root Cause

SCAR Ref Number :2024-00582 : 29/07/24

Problem:
Degassing equipment /Stirrer was not Cleaned, dried potting material observed on
stirrer cover.

1. Why Degassing equipment cover not cleaned?


Degassing equipment has attached with motor & Fixture accessories
which is not able to separate and entire setup will be replaced once in six month.

2. Why Degassing cover not replaced ?


No definition of replacing frequency of degassing Cover in cleaning Procedure

3. Why cleaning procedure not addressed replacement frequency?


Cleaning procedure not covered about degassing equipment cover cleaning &
replacement related requirement

4. Add another question here if applicable?


Because…

5. Add another question here if applicable?


Because…
Root Cause: Potting Operator not aware the cleaning of Degassing equipment cover
cleaning & Frequency of the replacing the degassing equipment top cover not defined
.