FusionModule2000 Smart Modular Data Center V100R021C00 Training Slides
FusionModule2000 Smart Modular Data Center V100R021C00 Training Slides
www.huawei.com
Medium and large data center Small data center Medium and large data center Small data center
Scenario-
specific
solutions
Core
products UPS2000-A/G UPS5000-E UPS5000-S UPS5000-S-FP SmartLi
1–20 kVA 25–800 kVA 50–800 kVA 990–1600 kVA
NetCol5000-A NetCol5000-C NetCol8000-A NetCol8000-C NetCol8000-E
11–42 kW 30–80 kW 13–120 kW 62–253 kW 220–440 kW
6
Copyright © Huawei Technologies Co., Ltd. All rights reserved.
Contents
1. Huawei Data Center Solution Portfolio
2. Version Evolution of the Smart DC and Smart Module
3. SmartDC V100R021C00 Smart Module System Introduction
4. SmartDC V100R021C00 Smart Module Site Survey Checklist
5. SmartDC V100R021C00 Smart Module Onsite Installation
6. Edge DC System Introduction and Installation
management
system Battery
IT equipment room
DC controller
Smart module: With the power supply and distribution module, cooling module,
and intelligent management as the core, the smart module contains the structure,
Smart DC = Smart module + DC controller + Management system
network, cabling, and fire extinguishing (optional) units. It provides an intelligent,
DC controller: links L0, L1, and L2 to provide an automatic control prefabricated, and integrated product solution with minimal PUE, minimal SUE, and high
system with low PUE, and uses BOX + control algorithm. availability.
Basic hardware: L0 outdoor (chiller and diesel generator); L1 indoor (smart module); L2 equipment (server and LAN switch)
Cooling system
partition boards, facilitating
Linkage between temperature, loads, and cooling cabinets
flexible cabling systems, ensuring the stable temperature field
Dual cable trough design,
AI self-optimization algorithm, reducing energy 3. Cooling system: in-row
separating electric and ELV consumption by 8% to 15%
optical fibers
Refrigerant capacity check, avoiding cooling air-cooled air
attenuation
Aisle system
conditioners
eLight module status
indicator Smart busway 4. Monitoring system:
Automatic lighting system
ECC800-pro, cameras,
Aisle-level access control
250 A/400 A
system
Power distribution branch temperature monitoring
Automatic sliding door Integrated UPS/Integrated PDF/Precision end cabinet
and multi-functional
Panoramic skylight, good-
light aisles Integrated UPS (60/125 kVA)
sensors
Aisle containment to isolate Integrated PDF (160/250 A)
5. Management system:
600/800 mm wide, 42 U/47 U
19-inch standard cabinet with
inspection robot
Lithium battery system
a static load of 1800 kg
Supporting electronic access
6. Integrated cabling
Monitoring system
control using IC cards Monitoring system 80 Ah/40.9 kWh system: internal power
Standard cabinet-level fire protection
ECC800 ring network monitoring
and signal cables
Local management and real-time
display on a pad or 43-inch
smart large screen 7. Auxiliary fire
System-level facial recognition
extinguishing system
Control skylight
Common (inherited) Small busway:
Maintainable (inherited) 250 A/400 A
(inherited)
Top sealing
plate (inherited)
Aisle door:
aisle door of version 3.0 (inherited; can be used
with the large screen)
aisle door of version 21A (newly developed, low-
cost, not supporting a large screen)
1. Installing the internal door frame 2. Installing guide rails 3. Installing rubber strips 4. Installing glass doors
5. Installing dampers 6. Installing door box hanging kits 7. Installing a magnetic lock 8. Installing door headers for the smart screen
9. Securing the external posts 10. Installing the external door frame 11. Installing bottom sealing plates
and door headers
12. Installing the large screen door box 13. Installing the smart screen
Function Configuration
Input subrack Function Configuration 60 kVA 125 kVA
Multiple cabinets combined: four cabinets (UPS input cabinet, output cabinet, UPS cabinet, and precision PDF) + two PDBs (lighting PDB and air conditioner
Power module
PDB)
25 kVA→30 kVA
Hot-swappable maintenance: The power module, control module, bypass module, and power distribution monitoring module are hot-swappable.
Visual management: The voltage, current, load rate, efficiency, and circuit breaker terminal temperature are visual.
2N and N+1 power supply architectures are supported.
1 Monitoring unit
Typical power backup time: 10 min/15 min/30
min/60 min
2 Battery switch Electrochemical cell: lithium iron phosphate
(LFP)
3 Fuse Nominal voltage: 512 V DC
Intelligent battery
Nominal capacity: 80 Ah/40.96 kWh
4 management module Discharge rate: 6C
5 Monitor screen
Operating voltage range: 400–544 V DC
Charge current: 0.1–1C (0.5C by default)
6 Lithium battery module Cycle life: 5000 cycles at 50% DOD
Cabling mode: top cabling
Combined cabinets: a maximum of eight cabinets
Standard cabinet-level fire extinguishing system
(excluding gas)
Dimensions: 600 mm x 850 mm x 2000 mm
1. Installing beams 2. Installing the outer top cover 3. Installing the bottom and side panels
4. Removing the rear door panel, rear door 5. Installing a tail frame 6. Installing the PVC panel
header, and rear door connecting kits
Manually changed
from Manual to
DHCP auto
Function Configuration
IT input
Function Configuration Scenario 1 Scenario 2
Air conditioner
input Lighting output 10 A/1P x 3
Branch Multiple cabinets combined: one cabinet (precision PDF) + two PDBs (lighting PDB and air conditioner PDB)
monitoring Hot-swappable maintenance: The power distribution monitoring module is hot swappable.
Visual management: The voltage, current, load rate, efficiency, and circuit breaker terminal temperature are visual.
2N and N+1 power supply architectures are supported.
Function Configuration
40 A/1P x 144
Output IT output 63 A/1P x 144
40 A/3P x 48
IT输 出
IT output 2000 mm x 600 mm x 1100 mm
Mechanical specifications (H x W x D) 2000 mm x 600 mm x 1200 mm
2200 mm x 600 mm x 1200 mm
Branch Hot-swappable maintenance: The power distribution monitoring module is hot swappable.
支 路 监 控
monitoring Visual management: The voltage, current, load rate, efficiency, and circuit breaker terminal temperature are visual.
A maximum of 48 IT cabinets are supported.
2N and N+1 power supply architectures are supported.
End plug apparent power, total reactive power, and neutral wire current; detects terminal temperatures to
reduce power outage and fire risks.
Elbow
Support
Indicator Meter
Cabinet Dimensions
Category Mains Input Branch Output
(H x W x D)
8 x 63 A/3P + 2 x 10 A/1P
Single route: 400 A
Air conditioner + 1 x 32 A/1P
Mains 800 x 600 x 300
input PDB 8 x 63 A/3P + 2 x 10 A/1P
Single route: 250 A
+ 1 x 32 A/1P
Level
C SPD
Mains
output
Lighting
output
A wall-mounted air conditioner PDB (8 routes) is configured for the N+1 scenario.
Two wall-mounted air conditioner PDBs are configured for the 2N scenario.
26 Ah 40
iBattery function description:
Implements wireless communication with the
40 Ah 40
iBOX.
Automatically identifies faulty batteries.
65 Ah 20
Detects the battery voltage, internal resistance,
and pole temperature.
100 Ah 20
Calculates the battery SOC and SOH.
iBattery Powers off the battery cabinet in case of fire.
Notes:
1. The mounting bracket is not required for the preceding rPDUs in 2000 mm high cabinets, but is required for the
rPDUs in 2200 mm high cabinets.
2. The mounting bracket is required for installing other manually inserted rPDUs. The rPDUs must be installed onsite.
3. Industrial connectors can be selected. For details, see the configuration manual.
Airflow mode Horizontal airflow 1356 (1217) x 1094 1356 (1217) x 2188
BOM number
Compressor Dimensions H1 BOM number
DC inverter compressor 52273541-005: 1107
type (H2) x W1 (W2) 52273539-005: 1107 (655) x
(655) x 2186 (2047) x
Fan type EC fan x D (unit: mm) 1356 (1217) x 1094
1094
Air filter G3 G4 BOM number
52273539-006: 1156 (703) x
Air-cooled half-sized Air-cooled full-sized Dimensions (H 1356 (1217) x 1094
inverter air conditioner inverter air conditioner x W x D, mm) 2000 x 300 x 1200 2000 x 600 x 1200 Storage
–40°C to +70°C
Low-temperature temperature
Net Altitude 0–4000 m, derated at above 1000 m. For detailed derating data, contact Huawei.
weight/Gross 230 kg/275 kg 350 kg/400 kg
CE, RoHS, RoHS 2.0, REACH, CQC, RoHS, RoHS 2.0,
weight Certification
WEEE REACH, CQC, WEEE
Outdoor –20°C to +55°C
ambient
operating –40°C to +45°C (requiring low-temperature
temperature components)
Low-temperature component information Port description for the NetCol5000-A035H/NetCol5000-A050 indoor unit
If the outdoor temperature is lower than the operating temperature range Item Netcol5000-A035H Netcol5000-A050
of a product, the condensing pressure of the outdoor unit may be lower Refrigerant liquid Reserved copper pipe: inner diameter of 5/8 inch, Reserved copper pipe: inner diameter of 5/8 inch,
pipe welded welded
than the safe operating pressure of the compressor, and a low- Refrigerant gas pipe
Reserved copper pipe: inner diameter of 3/4 inch, Reserved copper pipe: inner diameter of 7/8 inch,
welded welded
temperature component must be installed. The low-temperature
Reserved port: BSPP 1/2 inch, threaded
Reserved port: BSPP 1/2 inch, threaded
component supports the outdoor operating temperature of –40°C to connection connection
Water pump Recommended: PVC or PPR pipes, temperature
+45°C. drainpipe
Recommended: EPDM hose or PPR rigid pipe,
resistance of 85°C, pressure resistance of 1–7 kg,
Item Specifications temperature resistance of 85°C, pressure
inner diameter of 19 mm, outer diameter no greater
resistance of 1–7 kg, inner diameter of 12 mm,
BOM number 52271197 than 35 mm
outer diameter no greater than 30 mm
Refrigerant R410A Reserved port: BSPP 1/2 inch, threaded Reserved port: BSPP 1/2 inch, threaded
connection connection
Liquid pipe outer diameter 5/8 inch (15.88 mm) Humidifier water
inlet pipe Recommended: EPDM hose or PPR rigid pipe, Recommended: EPDM hose or PPR rigid pipe,
Gas pipe outer diameter 7/8 inch (22.22 mm) pressure resistance of 1–7 kg, inner diameter of pressure resistance of 0.1–0.7 MPa, inner diameter
12 mm, outer diameter no greater than 30 mm of 12 mm, outer diameter no greater than 16 mm
944 x 632 x 507 (with packaging)
Dimensions (H x W x D, mm) Reserved port: BSPP 1/2 inch, threaded
connection
828 x 470 x 300 (without packaging) Water tank Recommended: PVC or PPR pipes, temperature
N/A
automatic drainpipe resistance of 85°C, pressure resistance of 1–7 kg,
inner diameter of 19 mm, outer diameter no greater
Expansion bolt hole M12x60 than 35 mm
Storage temperature –40°C to +70°C Electric cable port Through hole: φ50 mm Through hole: φ50 mm
Item Specifications
Refrigerant R410A
Smart module
LAN switch
WiFi Zigbee
ECC800
DO DI
ECC800 PoE bus FE
Socket Socket Socket
TCP/IP RS485
AI/DI
ETH ETH
Zigbee Zigbee Zigbee Zigbee
temperature sensor
Multi-functional sensor x 2
In-room access
In-room video
T/H sensor
conditioner
In-room air
Access actuator x 2
VESDA
control
Chiller
Skylight actuator
HVDC
Integrated UPS
UPS
Integrated PDF
PDF
Water sensor
AC actuator
Camera x 2
Busbar
Rem
sen ote se
s
and or, sm nse: T
infr o /H Access control management
are ke se
Tele d n
Smart module PUE sky contro sen sor,
ligh l: sor
WiFi hotspot t
Camera
of four modules of two modules FusionModule
Peripheral devices of the
smart module
Enables deployment of both communications cables and power cables, which features abundant bandwidth
PoE bus power supply and communication Good performance and fast deployment
resources and easy deployment.
Intelligently adjusts and controls the air conditioner cooling capacity based on the cabinet temperature and
iCooling management Energy saving and emission reduction
energy consumption changes, saving energy.
Remote upgrade, inspection data export, Provides interfaces for remote upgrade, black box data export, and configuration file import and export,
Good serviceability
and configuration copy facilitating maintenance.
WiFi hotspot Provides local WiFi hotspots, enabling easy mobile phone access management. Wireless access with high availability
Huawei pad is deployed for the smart module. Monitoring information can be viewed or inspected without
Smart module check over pad Query over pad, facilitating O&M
entering the aisle.
Easy to use
Mobile app Apps are installed in mobile phones for query and management. Easy O&M through mobile apps
When a device is connected to the PoE bus, it can be automatically discovered and registered without
Plug-and-play and self discovery Short delivery time and high maintainability
configuration.
Linkage management The lighting and fire extinguishing systems are linked. Linkage rules can be customized. Linkage management and intelligent O&M
AC and DC dual power inputs Supports 220 V AC or 240 V DC power input. Dual power supplies with high reliability
Reliability
Battery monitoring management Monitors the single battery voltage and internal resistance and locates faulty batteries in a timely manner. Real-time monitoring of battery SOH
Northbound interface Supports interworking with the NetEco, allowing centralized management. Centralized management
WAN_1 (upper left), WAN_2 (lower left), LAN_1 (upper right), LAN_2 SMS Zigbee
(lower right)
2. Silk screens of RS485 serial ports:
COM1/12V (upper left), COM2/12V (lower left), COM3/12V (upper right),
USB DO port FE ports
PSU 1 PSU 2 RS485 ports
AI/DI ports
COM4/12V (lower right)
3. Silk screens of AI/DI and DO ports:
AIDI_1 (upper left), DO (lower left), AIDI_2 (upper right), AIDI_3 (lower ECC800-Pro (front view)
right)
4. Silk screen of the USB port: USB
5. External antenna ports: 3G/4G (left), WiFi (middle), Zigbee and RF
(right)
6. Silk screens of indicators: RUN, ALM, and Zigbee (from top to bottom)
Port description
AC ac
t u at o r
Skylig
h t a ct
u a to r
DI detection Three routes to detect the door status sensor, door open button, and fire linkage signals
Wiegand port Two Wiegand ports to connect to two card readers at the same time
Communication One FE port, one Zigbee wireless port, and one RS485 port. The FE and Zigbee ports are used for backup and the RS485 port is reserved (physical port cascading supported).
4-pin DIP switch One 4-pin DIP switch, used for setting the board address (1 by default)
Press the button for less than 1 second to start blinking. Hold down the button for 1–5 seconds to search for a network and start networking. Hold down the button for more than 6
Zigbee networking button
seconds to clear Zigbee network parameters.
Access control management Access permission management, access event record, and alarm record
AC ac
Cascading the
tuator
To a 53.5 V DC Skylig
power port 48V_PWR port on a ht act
smart gateway uator
To a LAN port Cascading the FE
port on a smart
gateway
Adaptive frame
1 Six-port 10/100M Ethernet switch
IT IT IT IT IT IT
2 Four network ports, supporting IEEE 802.3af/at PSE power supply cabinet cabinet cabinet cabinet cabinet cabinet
Supporting IEEE 802.3af/at for PoE, IEEE 802.3 for 10BaseT, and IEEE 802.3u for
3
100BaseT (X), and IEEE 802.3x for flow control
4 MDI/MDIX automatic interconnection
5 Storage and forwarding functions to ensure adaptivity and data integrity
Battery Battery IT IT IT IT IT
6 Automatic address learning function cabinet cabinet cabinet cabinet cabinet cabinet cabinet
7 IEEE 802.3x full-duplex flow control and forcible half-duplex flow control
8 Cascading port supporting the ring network
Item Specifications
AC IN: one AC input, 90 V AC to 240 V AC
Power input 48 V DC input: terminal, with an input voltage of 36 V DC to 60 V DC
AC OUT1: two AC outputs, 90 V AC to 240 V AC. The maximum current of each output is 5 A.
Power output AC OUT2: one AC output, 90 V AC to 240 V AC. The maximum current is 5 A.
COM1/COM2: two RS485 ports (one route) with a default communication rate of 9600 bit/s, physical
RS485 serial port port cascading (reserved)
COM3: southbound or northbound communication (reserved)
Access: One DO output port is used to control the power output of the electronic door lock, and
one DI input port is used to connect to the door status switch. Both ports use terminals.
DO/DI port Skylight: One DO output port is used to control the power output of the skylight magnetic lock,
and one DI input port is connected to the skylight open button. Both ports use terminals.
(1) 48 V DC power (2) LAN port (3) RS485 port (4) RS485 port Six AI/DI ports, in which one is for detecting the exit button, two for detecting lighting buttons, and one
AI/DI port
input port COM1/2 (reserved) for detecting fire extinguishing linkage signals. One port is reserved.
Two Wiegand ports, 12 V DC card reader operating power output; two routes of card readers (not
Wiegand port
fingerprint readers) can operate at the same time.
(5) DIP switch (6) AC OUT power (7) Terminal cover (8) AC IN power input
output port port Press the button for less than 1 second to start blinking.
BLINK button Hold down the button for 1–5 seconds to search for a network and start networking.
Hold down the button for more than 6 seconds to clear network parameters.
(9) Fuse (10) DO/DI port (11) DO/12V port (12) AI/DI port Address DIP switch 4-pin address DIP switch (reserved)
Fuse 16 A, 250 V AC
(13) Wiegand port (14) Spare fuse box (15) Indicator (16) BLINK button
Spare fuse box Two 16 A, 250 V AC fuses
E-label Supported
The smoke sensor detects the smoke density in the The smoke sensor is powered by the skylight Installation position: installed on the
aisle and generates fire alarms. controller. Alarm signals are reported to the control skylight
ECC800 by the actuator. Installation mode: mounted on the
top of the skylight
Fast Ethernet
Fast Ethernet
Smart Smart
module 1 module N
WiFi
ECC800
平 板 电 脑 /手 机
ECC800
AI/DI DO COM DI
……
智 能 ETH插 座 智 能 ETH插 座
eLight 开窗按钮
水浸传感器 声光告警器
FE
RF_Z(2)
The NetEco monitors and manages power, environment, security, and video systems in a unified manner. It can monitor and manage
a single modular and prefabricated data center, or modules or prefabricated data centers in multiple areas in a unified manner.
Integrated interface
SNMP JSON
Third-party system
Infrastructure Southbound NetEco
interface
Air conditioner
SNMP Building
SNMP
UPS
Smoke sensor
3. An emergency exit button is configured inside the aisle to open the door in case of
emergency. Skylight controller Module alarm beacon
Automatically opening
the skylight
fire extinguishing system in the equipment room. Closing openings and turning
off ventilation devices and air
Discharging extinguishants conditioners
after 0–30s
1. Route electric and ELV cables through holes at the bottom of cable troughs when the
cables are cross-connected.
Optical fiber
2. There are a large number of cables routed on end PDFs. In this case, route cables as
Network cable
shown in the preceding figure. Do not route cables from the bottom.
3. When the number of routed cables is not large (cables of less than 12 IT cabinets are
routed), route cables through skylights, with electric cables on the outer side and ELV
Cable routing plan cables on the inner side. When the number of routed cables is large, add cable trays.
AC input
Lamp 2
1 LCU
AC input
2
ATS 380 V AC AC
220 V AC
rPDU
1
Cable routing in N+1 configuration Cable routing in 2N configuration
UPS rPDU IT cabinet 1
2
380 V AC
380 V AC
380 V AC 380 V AC
220 V AC 220 V AC
480 V DC rPDU 220 V AC 220 V AC
1 480 V DC 480 V DC
Battery IT cabinet 2
rPDU
A single battery of 2 rPDU rPDU rPDU rPDU rPDU rPDU rPDU rPDU rPDU rPDU rPDU rPDU
12 V 1 2 1 2 1 2 1 2 1 2 1 2
iBattery iBattery iBattery iBattery iBattery
ĂĂ
iBattery iBattery iBattery iBattery
rPDU
1
rPDU IT cabinet 18 iBattery iBattery iBattery iBattery
2
Water sensor Air-cooled Chilled Air-cooled Chilled
Integrated PDF air water air Integrated PDF air water air
Battery cabinet IT cabinet IT cabinet IT cabinet Battery cabinet IT cabinet IT cabinet IT cabinet
Integrated cabling (PDF+UPS) conditioner conditioner (PDF+UPS) conditioner conditioner
Alarm beacon
cabinet 220 V AC cabinet cabinet cabinet cabinet
rPDU 12 V DC
1 iSCAN
rPDU controller IT cabinet
2 monitoring
48 V DC
Skylight
actuator
12 V DC
Integrated PDF 1 12 V DC
Lighting Light Lamp 48 V DC
Light tube 48 V DC
1 actuator 1 Light tube
Lamp
2 IT cabinet IT cabinet
AC input 380 V AC AC 1 monitoring monitoring IT cabinet IT cabinet
MCCB iSCAN controller (1 U) iBOX
1 LCU monitoring monitoring
iSCAN controller (1 U)
NVR (2 U)
220 V AC NVR (2 U)
UPS 1 rPDU
NetEco server (1 U)
1
IT cabinet 1 NetEco server (1 U)
rPDU
2 Air-cooled Chilled
air water air Air-cooled Chilled
480 V DC IT cabinet IT cabinet IT cabinet IT cabinet Integrated cabling cabinet
conditioner conditioner Integrated PDF air water air
cabinet cabinet Battery cabinet IT cabinet IT cabinet Integrated cabling cabinet
Battery 1
(PDF+UPS) conditioner conditioner
rPDU cabinet cabinet
A single battery 1
of 12 V rPDU IT cabinet 2
2
iBattery
ĂĂ
rPDU rPDU rPDU rPDU rPDU rPDU rPDU rPDU rPDU rPDU
Integrated PDF 2 1 2 1 2 1 2 1 2 1 2
Lighting rPDU
1
rPDU
2
rPDU
1
rPDU
2
rPDU
1
rPDU
2
2 rPDU 220 V AC 480 V DC
1 220 V AC 220 V AC
rPDU IT cabinet 18 380 V AC 220 V AC
2 380 V AC 380 V AC
AC input 380 V AC AC 2
Water sensor
380 V AC
MCCB
2 Integrated cabling
Alarm beacon
cabinet
220 V AC rPDU 220 V AC 12 V DC
UPS 2 1 iSCAN
NVR
iBOX
Camera unit. The outdoor unit cables are routed along pipes.
Power supply and distribution Three-in-one
sensor (infrared/
smoke/
diagram in 2N configuration temperature/
humidity)
Operating temperature for indoor equipment (including all Power supply 380–415 V AC (±10%); 3Ph; 50/60 Hz □ Passed □ Failed
components): 5°C to 40°C (long term), –5°C to +50°C (short
Environment term); storage temperature: –40°C to +70°C Equipment room: 500 lx
□ Passed □ Failed
requirement Operating temperature for air conditioner outdoor units: –30°C to Lighting Monitoring center: 500 lx □ Passed □ Failed
+45°C (long term); storage temperature: –40°C to +70°C Test area: 500 lx
Humidity: 5% to 85% (long term), 5% to 100% (short term)
pH: 7–8.5
Water source □ Passed □ Failed
Conductivity at 20°C (σ20): 300–1250 μs/cm
Floor drain DN50 or larger, made of cast iron or stainless steel □ Passed □ Failed
Standard live load of the main equipment room: 8–12 kN/m2 (If
the battery cabinet is placed inside the module, refer to the The equipment room grounding system must be a TN-S or
standard live load of the main equipment room.) Module TN-C-S system.
Floor load bearing □ Passed □ Failed
Hang load of the main equipment room: 1.2 kN/m2 □ Passed □ Failed grounding Ground bars must be deployed over the cable tray or under
capacity
Standard live load of the UPS room: 8–10 kN/m2 the raised floor.
Standard live load of the battery room: 16 kN/m2
Standard live load of the monitoring center: 6 kN/m2 Condensate drain outlet: for draining condensate from the air
□ Passed □ Failed
conditioner
Cooling port
Humidifier water pipe port: connects to external water pipes to
□ Passed □ Failed
supply water to the humidifier.
2000 mm high cabinet: ≥ 2600 mm; ≥ 2800 mm (NMW scenario)
Equipment room net One LAN switch Ethernet port: connects to the customer
2200 mm high cabinet: ≥ 2800 mm; □ Passed □ Failed □ Passed □ Failed
height subnet to monitor devices inside the module.
≥ 3000 mm (NMW scenario)
Monitoring port One skylight controller dry contact: connects to the fire
extinguishing system to link the fire extinguishing system and □ Passed □ Failed
Height and width of the the skylights.
Height: ≥ 2200 mm
equipment aisle and □ Passed □ Failed
Width: ≥ 1200 mm
door
Floor levelness Allowed deviation: 3 mm/2000 mm □ Passed □ Failed For details about the survey checklist, see the Survey Report.
Elevator bearing capacity: > 2 t
Elevator □ Passed □ Failed
Elevator door size: height > 2100 mm; width > 1500 mm
Perform site survey based Basic installation tools: Emphasize Install the smart Checking the installation:
on the survey guide, Phillips screwdriver; construction safety. module based on the Check whether the cabinets
especially the aisle, door, small-sized flat-head Provide training in process specified in and skylights are properly
elevator, and material screwdriver; the installation the one-page installed, whether gaps
placement plans. open-end wrench; process, installation guide, and between parallel cabinets are
ink fountain or laser documents, and connect cables based even, whether electric and
wire gauge fixtures. on the cabling diagram ELV cables are separately
Provide help- in package 0. routed and tightly bound, and
seeking channels. whether end doors are
smoothly opened and closed.
Enclosure Enclosure
frame frame
Control
skylight
Enclosure Enclosure
Fixtures
frame frame Skylight controller
Integrated
Battery Battery IT AC cabinet IT IT IT AC cabinet IT
cabling
cabinet cabinet cabinet A/C 03 cabinet cabinet cabinet A/C 04 cabinet
cabinet
Tail frame
baselines.
4. Use marking-off templates to drill holes on the ground.
5. Level cabinets. Ink compression cotton
3 by opening the cover.
6. Use fixtures to adjust the aisle distance.
7. Install tail and enclosure frames (remove accessories and install
foolproof devices and ground cables). Pull out the ink
Leveling precautions: 5
line. Movable. Rotate the cover Adjust the height.
8. Install and level aisle doors and adjust gaps between doors. to replace the line. Spool
Mark installation borders according to the Level four angles.
9. Connect cabinet cables based on the cabling diagram for PDF cabinet installation guide. Check height
ECC800-Pro Item 42 U
Built-in fire
extinguishing system 6 kVA UPS
IP rating IP20
Rack-mounted
Maximum power of a single cabinet 3 kW
cooling system
Installation mode Installed on a concrete floor or an ESD floor
Rated input voltage 220 V AC/230 V AC/240 V AC Cycle life 3500 cycles at 0.5C, 85% DOD, 70% EOL, 35°C
(1) LCD (2) Maintenance bypass (MBS) port (3) BMS ports Wiring terminal M6, torque: 4 N·m
(4) RS232 communications port (5) RS485 communications ports (6) USB port (protected by a security Installation mode Installed in a 19-inch rack
(connect to northbound devices) protection mechanism) Normal mode: 93% (online mode)
Peak efficiency Overtemperature protection, overcurrent protection, short
(7) AC input and output terminals
(behind the cover)
(8) Battery input terminal (behind the
cover)
(9) 48 V DC output terminal (reserved) Normal mode: 90% Protection function circuit protection, overcharge protection, and overdischarge
protection
(10) Parallel current equalization ports (11) EPO ports (12) Parallel communications ports
(only for parallel UPSs) (only for parallel UPSs) Storage temperature② 0–40°C
Dimensions (H x W x D) 130.8 mm x 438 mm x 420 mm
Transportation temperature –40°C to +60°C
Weight 15 kg
Operating temperature③ Charge: 0–45°C; discharge: –20 to +45°C
Refrigerant R410A
a: The cooling capacity is obtained when the indoor dry bulb temperature is 37°C, the indoor wet bulb
temperature is 24°C, and the outdoor dry bulb temperature is 35°C. The actual cooling capacity varies
Air depending on the indoor and outdoor ambient temperatures and relative humidity.
conditioner
Water sensor
LAN switch Water leakage monitoring: detects water leakage at the bottom of the smart
Smoke sensor
SPD
module and provides real-time alarm signals.
T/H sensor
1
T/H sensor
2
Smoke monitoring: detects smoke in the smart module and provides real-
Rack-mounted air time alarm signals.
conditioner
Power distribution monitoring: monitors the UPS input voltage, frequency,
and current.
Smart cooling product monitoring
Video surveillance
App view
WiFi module
extinguishing system
Generates a 2.5D layout diagram that matches the actual layout of the
UPS
PAD Displays the real-time status monitoring data and alarms of the aisle
temperature and humidity on the floor plan.
Smart spring lock 2 Supports facial recognition on the pad app.
Fe-lithium battery Allows you to open the cabinet door on the corresponding screen after
logging in to the app installed on the pad.
Linkage control
Supports the linkage logic of aisle smoke alarms or high temperature
alarms. By default, the cabinet doors are opened through linkage.
• To avoid fire disasters, install an outdoor unit in a dry and well-ventilated place without flammable gas leakage.
• Select a place away from direct sunshine and radiation from other heat sources. If the sunshine or heat radiation cannot
be avoided, cover the outdoor unit.
• Do not install an outdoor unit in a place with much salt or corrosive gas.
• When installing the outdoor unit, ensure that the air intake vent and air exhaust vent of the condenser are not dirty or
2 Installing an Indoor Unit blocked. Install an outdoor unit in clean areas that are away from residential areas.
• At a high place with strong winds, install the outdoor unit against a wall to ensure the normal operating of fans. Install
1. Remove filler panels. baffle plates when necessary to prevent wind from blowing down the outdoor unit.
• Try to install an outdoor unit against a wall. If the site conditions cannot meet the requirements and the local outdoor
2. Push the indoor unit into the bottom of the cabinet along the guide rails. temperature may be below –10°C, prepare and install an air baffle by referring to the space requirements. The air baffle
height and width should be greater than or equal to the outdoor unit height and width, respectively.
• If the site installation environment is complicated and the preceding conditions are not met, contact Huawei technical
support.
Air exhaust side: > 2000 mm Air intake side: > 150 mm
5.3 Installing the PDU2000 1. Adjust the pad mounting support to match the dimensions of the pad to be installed.
2. Remove the nuts from the pad mounting support and install the support.
3. Route the pad power cable through the cable hole and connect the cable.
4. Clamp the pad.
5. Connect the ECC800 USB cable to the charging port on the pad.
Adjusting
screws
1. Unpack the two T/H sensors and attach them to the posts on the front and rear doors of the cabinet.
2. Connect the T/H sensor monitoring cables to connect the T/H sensors to the NetCol control unit in series.
the ECC800.
Connect input power cables to the PDU. Connect input power cables to the PDU.
Connect one end of a network cable to the
Cabinet
3 Connecting PDU2000 Power Cables RS485_IN port on the electronic clasp lock
on the front door of the cabinet, and
connect the other end to the COM2 port on
the ECC800-Pro. Connect one end of
another network cable to the OUT port on
the electronic clasp lock on the front door of
the cabinet, and connect the other end of
the network cable to the RS485_IN port on
the electronic clasp lock on the rear door of
(Front) the cabinet.