Pabilan Load Combinations
Pabilan Load Combinations
LOAD
COMBINATIONS
BY: Cielo Pabilan
Section 203.2 Symbols and Notations
• D = Dead Load • R = Rain Load
• E = Earthquake Load
• T = self-straining force and
• = Estimated Maximum
effects resulting from
Earthquake force
temperature change,
• F = Loads due to fluids shrinkage, moisture change,
• H= Loads due to lateral
pressure of soil and creep, settlement
water in the soil • P= Ponding Load
1.4 (D + F)
1.2 (D + F + T) + 1.6 (L or H) + 0.5 ( or R)
1.2D + 1.6(Lr or R) + L + (L or 0.5W)
Where;
1.2D + 1.0W + L + 0.5( or R)
= 1.0 for floors in
1.2D + 1.0E + L places of public
assembly, for live
0.9D + 1.0W +1.6H loads in excess of 4.8
kpa, and for garage
live load, or 0.5 for
0.9D +1.0E +1.6H other live loads
Section 203.4.1 Allowable Stress Design (ASD)
D+F
D+H+F+L+T
D + H + F + ( or R)
D + H + F + 0.75 [L + T ( or R)]
D + H + + (0.6W or )
Section 203.4.2 Alternate Basic Load Combination
D + H + F + 0.75 [L + (0.6W or
0.6D + 0.6W + H
0.6D + + H
D + L + ( or R)
D + L + 0.6W
D + L +)
Section 203.5 Special Seismic Load Combination