The document provides specifications for two hematology analyzers, the Dymind DF51 and Mindray BC-5000, highlighting their capabilities, sample requirements, and reagent information. Both analyzers offer high throughput and advanced cell differentiation with low blood consumption, making them suitable for various patient demographics. Additionally, a comparative matrix outlines their performance against other models, detailing parameters such as throughput, storage capacity, and reportable parameters.

Uploaded by

bstctechnical
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views10 pages

5 parts without autoloader

The document provides specifications for two hematology analyzers, the Dymind DF51 and Mindray BC-5000, highlighting their capabilities, sample requirements, and reagent information. Both analyzers offer high throughput and advanced cell differentiation with low blood consumption, making them suitable for various patient demographics. Additionally, a comparative matrix outlines their performance against other models, detailing parameters such as throughput, storage capacity, and reportable parameters.

Uploaded by

bstctechnical
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 10

5 Parts Hematology

Analyzer
(Without Autoloader)
Applications Department
Biotech Systems Trading Corporation
Dymind
• Laser scatter + Chemical dye + Flow
DF51 cytometry
• 5-part differentiation, 27 parameters
• Up to 60 samples per hour
• Independent channel for Basophil
measurement
• 10.4 inches high resolution TFT touch
screen
• Powerful capability to flag abnormal
cells
• Large storage capacity: up to 50,000
samples
• Fast Turn-Around-Time
• 60 Samples/ hr
Low Blood Consumption

• 15μL ultralow sample requirement, more suitable for children and old
people
Various test modes

• Venous Blood CBC+DIFF


• Venous Blood CBC
• Capillary Blood CBC+DIFF
• Capillary Blood CBC
• Prediluted CBC+DIFF
• Predilute CBC
Powerful Parameters
Reagent Information
Reagent Name Shelf Life Contents Open Life

Diluent DIL-C 24 months 20 L 60 days

Lyse LYC-1 24 months 200 mL 60 days

Lyse LYC-2 24 months 500 mL 60 days

Cleanser CLE-P 24 months 50 mL 60 days

• Storage temperature: 2-30℃


• Operation temperature: 10-30℃
Sample Probe Anti-Block Design
• Tri-angle Laser scatter +
Mindray BC- Chemical dye + Flow cytometry
technology
5000 • WBC 5-part differentiation, 23
reportable parameters, 3
histograms and 3 scattergrams
• Whole blood mode, Capillary
whole blood mode and
Prediluted mode
• Dedicated optical counting
channel for Basophil
measurement
• Powerful capability of flagging
abnormal cells
• 10.4 inch large TFT touch
screen with user-friendly
software
• Large storage capacity: up to
Reagent Information
Reagent Name Shelf Contents Open Life
Life

Diluent M-52D 24 20 L 60 days


months
Lyse M52D LH Lyse 24 100 mL 60 days
months
Lyse M52D Diff Lyse 24 500 mL 60 days
months
Cleanser Probe Cleanser 24 50 mL 60 days
months

• Storage temperature: 2-30℃


• Operation temperature: 10-30℃
Comparative Matrix
Specifications Mindray BC-5000 Dymind DF51 Sysmex XN-330 Beckman DxH500 Hycel Hycount 5
Throughput 40 samples/hour 60 samples/hour 60 samples/hour 60 samples/hour 40 samples/hour
Principle Tri-angle Laser Laser scatter + Flourescent Flow
Cytometry
Coulter Tri-angle
scatter + Chemical dye + Principle and
(WBC/Ret), direct Laser scatter
Chemical dye + Flow cytometry currenet impedance
method with
flow cytometric
sheath flow
Flow cytometry hydrodynamic optical
focusing (RBC/PLT), measurement +
technology cyanide free SLS Impedance
method (HGB)
+
Colorimetry
for HGB
Storage Up to 20,000 Up to 50,000 Up to 100,000 Up to 30,000 Up to 30,000
samples samples samples samples samples
Sample 15ul 15ul 25ul 12 ul 20 ul
volume (whole
blood)
Reportable 23 parameters 27 parameters 28 parameters 21 parameters 26 parameters
parameters
Reagents 4 reagents 4 reagents 3 reagents
Histogram + 3+1 3+1 2+4
Scattergram

You might also like