Reactive Power Control Using Inverters

The document discusses reactive power control using Voltage Source Inverters (VSI) and Current Source Inverters (CSI), highlighting the power relationships and phasor diagrams. It explains that there is no DC current in VSI or DC voltage in CSI when the load power factor is zero, and that reactive power is exchanged among phases without affecting the DC circuit. Additionally, it notes that the sizes of capacitors in VSI and inductors in CSI do not influence reactive power on the AC side, which is solely related to active power on the DC side.

Uploaded by

aryo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views

Reactive Power Control Using Inverters

The document discusses reactive power control using Voltage Source Inverters (VSI) and Current Source Inverters (CSI), highlighting the power relationships and phasor diagrams. It explains that there is no DC current in VSI or DC voltage in CSI when the load power factor is zero, and that reactive power is exchanged among phases without affecting the DC circuit. Additionally, it notes that the sizes of capacitors in VSI and inductors in CSI do not influence reactive power on the AC side, which is solely related to active power on the DC side.

Uploaded by

aryo
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPTX, PDF, TXT or read online on Scribd
You are on page 1/ 3

Reactive Power Control Using Inverters

VSI CSI
Phasor Diagram (Source Notation)

VSI

CSI
Power Relationship
ed id va ia  vb ib  vc ic
va  2V sint  vb  2V sin t  23   
vc  2V sin t  23 

ia  2 I sint    ib  2 I sin t  23    
ic  2 I sin t  23   
ed id VI cos 1  cos2t   VI sin  sin2t 
   
 VIcos 1 - cos 2t  23  VIsinsin 2t  23 
 VIcos 1 - cos2t - 23   VIsinsin 2t - 23 
3VIcos

No dc current in VSI and no dc voltage in CSI when the load power factor is zero.
The reactive power is interchanged among phases without involving the dc circuit.
Thus, the sizes of C in VSI and L in CSI have no relationship with the reactive power