PROFIBUS PA is a protocol designed for process automation, based on the DP and DP Extended protocols, enabling control of both DP and PA field devices. It utilizes a physical layer compliant with IEC 1158-2, allowing synchronous data transfer with power and data transmitted over the same wire at a rate of 31.25kbaud. The document outlines network setup rules, addressing, topology, and the PA profile, which defines application layer specifications for device interoperability.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views

Chapter 7

PROFIBUS PA is a protocol designed for process automation, based on the DP and DP Extended protocols, enabling control of both DP and PA field devices. It utilizes a physical layer compliant with IEC 1158-2, allowing synchronous data transfer with power and data transmitted over the same wire at a rate of 31.25kbaud. The document outlines network setup rules, addressing, topology, and the PA profile, which defines application layer specifications for device interoperability.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PPT, PDF, TXT or read online on Scribd
You are on page 1/ 18

PROFIBUS PA

 PROFIBUS PA = PROFIBUS for Process


Automation
 PA is based on the DP and DP Extended protocol
 DP Master Class 1 controls both DP AND PA field
devices
 Definitions for DP protocol also valid for PA:
 Parameterization
 Configuration
 Cyclic data exchange
 Diagnostic
 ...

s PROFIBUS PA
Date 09/19/00, Page 1
PROFIBUS PA

 Physical Setup
 Physical layer based on IEC 1158-2
 Synchronous data transfer with Manchester coding
 Power AND data are transferred via the same wire
 Different components for the physical setup (cable,
connectors, termination…)
 Rules regarding topology and length according to
IEC 1158-2
 Transmission rate is 31.25kbaud

s PROFIBUS PA
Date 09/19/00, Page 2
PROFIBUS PA

 Physical Setup (continued) - Comparison

RS485 IEC 1158-2


Physics
wire carries data only wire carries data and power

9,6K; 19,2K; 45,45K; 93,75K; Transmission 31,25K


187,5K; 1,5M; 3M; 6M; 12M Rate

NRZ (No Return to Zero) Coding Manchester

11 bits per data byte 8 bits per data byte


1 start bit, 8 data bits (LSB first) Character
8 data bits (MSB first)
Format
1 parity bit (even parity), 1 stop bit
1 parity bit for each character 16 bit CRC (Cyclic Redundancy
Check Check)
1 byte FCS check sum Sequence
(Frame Check Sequence)

s PROFIBUS PA
Date 09/19/00, Page 3
PROFIBUS PA

 Message Structure
SD LE LEr SD DA SA FC DU.. FCS ED

P SOF SD LE LEr SD DA SA FC DU.. CRC EOF

P: 16 Bit Preample
SD: Start Delimiter
LE: Net Data Length (DU) + DA, SA , FC, DSAP, SSAP
LEr: Length repeated
DA: Destination Address (Where the message goes to)
SA: Source Address (Where the message comes from)
FC: Function Code ( FC=Type & Priority of Message)
DU: Data Unit (Up to 246 Bytes including 2 Bytes for SAP’s)
FCS: Frame Checking Sequence
CRC: 16 Bit Cyclic Redundancy Check
ED: End Delimiter
EOF: End Of Frame

s PROFIBUS PA
Date 09/19/00, Page 4
PROFIBUS PA

 Character Format

Clock

Binary 0 1 0 1 0 0 1 1 0 0 1 1 0 0 0 1 0

+
„1“
NRZ 0
(PROFIBUS) „0“ 0

+
Manchester „1“ 0
Bitphase L 0 -
(PROFIBUS-PA) +
„0“ 0
-
s PROFIBUS PA
Date 09/19/00, Page 5
PROFIBUS PA
 Network Addressing

1 1
PROFIBUS PROFIBUS
45.45kbaud up to 12Mbaud

PA Link
2 X PA Link
3 X
X PA X PA 24 V
PA
24 V
PA
24 V
Coupler
24 V
Coupler 1 Coupler
1 Coupler

2 3 4 3 4 3
PROFIBUS PA 31.25kbaud

s PROFIBUS PA
Date 09/19/00, Page 6
PROFIBUS PA

 Network Topology

Spur
Line
PROFIBUS

Star

(Main) Line
24 V

PROFIBUS PA T Branch Termination

s PROFIBUS PA
Date 09/19/00, Page 7
PROFIBUS PA

 Network Topology (continued)

+
-

s PROFIBUS PA
Date 09/19/00, Page 8
PROFIBUS PA
 Network Setup - Rules (continued)

PA
24 V Coupler

Up to 31 PA field
devices can be
connected to ONE
coupler

s PROFIBUS PA
Date 09/19/00, Page 9
PROFIBUS PA

 Network Setup - Rules

Up to 5 couplers can be used with one link

= PA Link = PA Coupler

s PROFIBUS PA
Date 09/19/00, Page 10
PROFIBUS PA
 Network Setup - Rules (continued)

PA Link PA
Coupler
24 V

Up to 31 PA field devices
can be connected to ONE
link - INDEPENDENT of the
number of couplers

s PROFIBUS PA
Date 09/19/00, Page 11
PROFIBUS PA
 Network Setup - Rules (continued)

PA Link PA
Coupler
24 V

I Maximum current flow per coupler:


400mA for x
110mA for EEx [ib] II C ignition protection
90mA for EEx [ia] II C ignition protection

s PROFIBUS PA
Date 09/19/00, Page 12
PROFIBUS PA

 Network Setup - Rules (continued)

24 V
Maximum segment length
per coupler = 1,900m

s PROFIBUS PA
Date 09/19/00, Page 13
PROFIBUS PA
 Network Setup - Rules (continued) (Allowed Length
PER Drop/Spur Line)

140
120
120

100 Maximum L ength


90
(Non E x) [m]
80
Maximum L ength
60 60 (E x) [m]

40 30
30 30 30
20

0
1..12 13..14 15..18 19..24

[Number of Spur Lines]

s PROFIBUS PA
Date 09/19/00, Page 14
PROFIBUS PA

 PA Profile
 Definition on the application layer level
 Profile defines variables, function blocks, meaning of
the data, mapping to communication services...
 Devices with the same profile implemented can be
exchanged
 Current version of PA Profile is V3.0
 Available as official PROFIBUS International
document with order no. 3.042
 Pre-defined GSD files for various PA field devices
available

s PROFIBUS PA
Date 09/19/00, Page 15
PROFIBUS PA

 PA Profile (continued)

Status DP services
cyclic and
Measured value acyclic

Profile B
Measuring range

Filter time
(e.g. for
Alarm/warning limits pressure
DP Services transmitters)
Alarm summary acyclic

TAG

Manufacturer-specific DP services
parameters acyclic

s PROFIBUS PA
Date 09/19/00, Page 16
PROFIBUS PA
 Electronic Data Sheets

GSD File for description of


PROFIBUS-PA communication parameters

GSD
PROFIBUS
Configuration Tool

DD PROFIBUS
Engineering Tool
PA Field
Device Device Description File for
specification of functionality

s PROFIBUS PA
Date 09/19/00, Page 17
PROFIBUS PA

 Engineering Tool
PROFIBUS (up to 12 Mbaud)

Engineering Tool
(Diagnostic Master)

Direct access to field


device via DP
Extensions (e.g.
to change range of
measurement)

PROFIBUS-PA (31.25 kbaud)

s PROFIBUS PA
Date 09/19/00, Page 18