Heating/cooling On/Off
Operation Mode
Target Temperature (if a room-stat has been installed, please refer to the manufacturer manual)
• DHW heating by heat pump and DHW heater without delay time
※ Available When DHW tank and heater are installed and DHW Heating enable status
• Push and hold Back button for 3 seconds with focus target temperature for DHW heating
• Not available when Locked
Information Display
Temperature monitoring Operation information
• Display temperature and operation status by Back button area area
- Why the radiators temperature changes when the “Auto mode” is activated?
- When the Heat pump is set on Auto mode, the controller monitors the outside air ambient temperature and adjusts the radiator temperature, when
the weather turns cold, the radiators become warmer to keep the house at the same temperature.
- Since I replaced my old oil boiler for a heat pump, my electricity bills increased?
- The heat pump is using electricity, so it is important to make sure you have the best deal from your electricity supplier. Bare in mind for one kilowatt
absorbed, the heat pump will produce up to 4.9 kilowatt.
- When the weather is cold, I can regularly see steam out of my heat pump?
- When the weather is cold, close to zero degrees, the evaporator gets very cold and the moisture in the air freezes it, so when the controller feel the
needs for it, a defrost mode is engaged to melt the frost from the heat exchanger and becomes more efficient. At the end of the cycle, the fan(s) restart
and blow away a plume of steam.