                                                                 Part Number: AA–RTD1C–TE


This guide describes how to install, configure, and use the diagnostic utilities for the HP
StorageWorks A7298A host bus adapter for Windows Server 2003 and Linux platforms.
© Hewlett-Packard Company, 2003. All rights reserved.
Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited
to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be
liable for errors contained herein or for incidental or consequential damages in connection with the furnishing,
performance, or use of this material.
This document contains proprietary information, which is protected by copyright. No part of this document may be
photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard.
The information contained in this document is subject to change without notice.
Intel® is a U.S. registered trademarks of Intel Corporation.
Microsoft®, MS-DOS®, MS Windows®, Windows®, and Windows NT® are U.S. registered trademarks of
Microsoft Corporation.
Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The
information is provided “as is” without warranty of any kind and is subject to change without notice. The warranties
for Hewlett-Packard Company products are set forth in the express limited warranty statements for such products.
Nothing herein should be construed as constituting an additional warranty.
Printed in the U.S.A.


Host Bus Adapter for Windows and Linux Installation Guide
Third Edition (April 2003)
Part Number: AA–RTD1C–TE
contents



                                                            Contents
    About this Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
    Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
        Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
        Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
    Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
        Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
        Text Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
        Equipment Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
    Rack Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
    Getting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
        HP Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
        HP Storage Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
        HP Authorized Reseller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

1   Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
    Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
    Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
    Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
    Boot BIOS Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
        Enabling Boot BIOS and External Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
    Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
    Agency Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

2   Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
    Installation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
    Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
    Recording Reference Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
    Installing the HBA into a Computer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
    Verifying the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
    Configuration Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29


Host Bus Adapter for Windows and Linux Installation Guide                                                                                      3
Contents



3   Installing the SCSI Miniport Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
    Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
    Windows Server 2003 Device Driver Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
        Windows Server 2003 System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
        Installing the Windows Server 2003 SCSI Miniport Driver . . . . . . . . . . . . . . . . . . . . . . 32
        Removing the Windows Server 2003 SCSI Device Driver . . . . . . . . . . . . . . . . . . . . . . . 33
    Linux Device Driver Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
        Linux System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
    Installing the Linux Driver Using a Tar File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
    Installing the Linux Driver Using an RPM File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
    Building the Driver as a Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
    Loading the Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
        Loading the Driver Manually. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
        Loading the Driver Through the RAM Disk Image. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
    Building the Driver Into the Kernel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
        SCSI Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
        IP Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
    Setting up and Running Diagnostic Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
    Installing the Latest Version of HBA API and Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

4   Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
    Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
    POST Conditions and Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
    Using The Event Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
    Windows Miniport Event Log Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
    SCSI Address Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
        Fabric Device Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
        Private Loop Device Mapping for Windows Platforms. . . . . . . . . . . . . . . . . . . . . . . . . . 57

5   Diagnostic and Configuration Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
    The DOS Diagnostic Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
       Starting the DOS Diagnostic Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
       Using the DOS Diagnostic Utility for Preliminary Testing . . . . . . . . . . . . . . . . . . . . . . . 67
       DOS Diagnostic Utility Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
    LightPulse Utility/NT Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
       View HBA Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
       Maintaining HBA Firmware Revision Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
       Modify Diagnostic Driver Parameters in the Windows Registry . . . . . . . . . . . . . . . . . . 72
       Modify the Driver Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73


4                                                                   Host Bus Adapter for Windows and Linux Installation Guide
Contents



           Test Host Bus Adapters (For lputilnt Only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                      76
           Modify Test Options (For lputilnt Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                    77
           Reset Host Bus Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .            77
           Input/Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   77
           Show Host Bus Adapter Info (For lputilnt Only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                          77
           Quit the LightPulse Utility/NT Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .                 78

A Regulatory Compliance Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79
  FCC Compliance Information Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
     Japanese Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
     Canadian Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
          Avis Canadien . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
  Federal Communications Commission Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
     Japanese Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
     Canadian Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
          Avis Canadien . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82

     Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83

     Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89

     Figures
     1 Host Bus Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

     Tables
     1 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
     2 Host Bus Adapter Diagram Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
     3 Normal POST LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
     4 Normal POST LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
     5 SCSI Port Error Log Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
     6 CmdStat Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
     7 Parameter Error Values Valid only when CmdStat=0x3 . . . . . . . . . . . . . . . . . . . . . . . . . 55
     8 Current Private Loop Device Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
     9 DOS Diagnostic Utility Command Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
     10 DOS Diagnosis Utility Main Menu Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
     11 Driver Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
     12 AL-PA Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76




Host Bus Adapter for Windows and Linux Installation Guide                                                                                        5
Contents




6          Host Bus Adapter for Windows and Linux Installation Guide
about this
                                                                                    guide


                                      About this Guide
                  This installation guide provides information to help you:
                  ■    Install, configure, and Aboutthe diagnostic utilities for the HP StorageWorks
                                               use this Guide
                       A7298A host bus adapter for Windows and Linux platforms.
                  ■    Contact technical support for additional assistance.
                  “About this Guide” topics include:
                  ■    Overview, page 8
                  ■    Conventions, page 9
                  ■    Rack Stability, page 12
                  ■    Getting Help, page 13




Host Bus Adapter for Windows and Linux Installation Guide                                              7
About this Guide



Overview
                   This section covers the following topics:
                   ■   Intended Audience
                   ■   Related Documentation

Intended Audience
                   This book is intended for use by system administrators who are experienced with
                   the following:
                   ■   Windows Server 2003
                   ■   Linux Red Hat Advanced Workstation v2.1 (Itanium processor)
                   ■   Host bus adapters

Related Documentation
                   In addition to this guide, HP provides corresponding information:
                   ■   hp StorageWorks release notes — host bus adapter for Windows and Linux




8                                                 Host Bus Adapter for Windows and Linux Installation Guide
About this Guide



Conventions
                  Conventions consist of the following:
                  ■    Document Conventions
                  ■    Text Symbols
                  ■    Equipment Symbols

Document Conventions
                  The document conventions included in Table 1 apply in most cases.
                  Table 1: Document Conventions
                                    Element                                  Convention
                   Cross-reference links                       Blue text: Figure 1
                   Key and field names, menu items,            Bold
                   buttons, and dialog box titles
                   File names, application names, and text     Italics
                   emphasis
                   User input, command and directory           Monospace font
                   names, and system responses (output         COMMAND NAMES are uppercase
                   and messages)                               monospace font unless they are case
                                                               sensitive
                   Variables                                   <monospace, italic font>
                   Website addresses                           Blue, underlined sans serif font text:
                                                               http://www.hp.com


Text Symbols
                  The following symbols may be found in the text of this guide. They have the
                  following meanings.


                           WARNING: Text set off in this manner indicates that failure to follow
                           directions in the warning could result in bodily harm or death.




Host Bus Adapter for Windows and Linux Installation Guide                                                9
About this Guide




                           Caution: Text set off in this manner indicates that failure to follow directions
                           could result in damage to equipment or data.



                   Note: Text set off in this manner presents commentary, sidelights, or interesting points
                   of information.



Equipment Symbols
                   The following equipment symbols may be found on hardware for which this guide
                   pertains. They have the following meanings.


                                   Any enclosed surface or area of the equipment marked with these
                                   symbols indicates the presence of electrical shock hazards. Enclosed
                                   area contains no operator serviceable parts.

                                   WARNING: To reduce the risk of personal safety from electrical shock
                                   hazards, do not open this enclosure.



                                   Any RJ-45 receptacle marked with these symbols indicates a network
                                   interface connection.

                                   WARNING: To reduce the risk of electrical shock, fire, or damage to the
                                   equipment, do not plug telephone or telecommunications connectors
                                   into this receptacle.



                                   Any surface or area of the equipment marked with these symbols
                                   indicates the presence of a hot surface or hot component. Contact with
                                   this surface could result in injury.

                                   WARNING: To reduce the risk of personal safety from a hot
                                   component, allow the surface to cool before touching.




10                                                   Host Bus Adapter for Windows and Linux Installation Guide
About this Guide




                                         Power supplies or systems marked with these symbols indicate the
                                         presence of multiple sources of power.

                                         WARNING: To reduce the risk of personal safety from electrical
                                         shock, remove all power cords to completely disconnect power
                                         from the power supplies and systems.



                                   Any product or assembly marked with these symbols indicates that the
                                   component exceeds the recommended weight for one individual to
                                   handle safely.

                                   WARNING: To reduce the risk of personal safety or damage to the
                                   equipment, observe local occupational health and safety requirements
                                   and guidelines for manually handling material.




Host Bus Adapter for Windows and Linux Installation Guide                                              11
About this Guide



Rack Stability
                   Rack stability protects personnel and equipment.


                           WARNING: To reduce the risk of personal safety or damage to the
                           equipment, be sure that:
                           ■ The leveling jacks are extended to the floor.
                           ■ The full weight of the rack rests on the leveling jacks.
                           ■ In single rack installations, the stabilizing feet are attached to the rack.
                           ■ In multiple rack installations, the racks are coupled.
                           ■ Only one rack component is extended at any time. A rack may become
                              unstable if more than one rack component is extended for any reason.




12                                                  Host Bus Adapter for Windows and Linux Installation Guide
About this Guide



Getting Help
                  If you still have a question after reading this guide, contact an HP authorized
                  service provider or access our website: http://www.hp.com.

HP Technical Support
                  Telephone numbers for worldwide technical support are listed on the following
                  HP website: http://www.hp.com/support/. From this website, select the country
                  of origin.


                  Note: For continuous quality improvement, calls may be recorded or monitored.


                  Be sure to have the following information available before calling:
                  ■    Technical support registration number (if applicable)
                  ■    Product serial numbers
                  ■    Product model names and numbers
                  ■    Applicable error messages
                  ■    Operating system type and revision level
                  ■    Detailed, specific questions

HP Storage Website
                  The HP website has the latest information on this product, as well as the latest
                  drivers. Access storage at: http://www.hp.com/country/us/eng/prodserv/
                  storage.html. From this website, select the appropriate product or solution.

HP Authorized Reseller
                  For the name of your nearest HP authorized reseller:
                  ■    In the United States, call 1-800-345-1518
                  ■    In Canada, call 1-800-263-5868
                  ■    Elsewhere, see the HP website for locations and telephone numbers:
                       http://www.hp.com.



Host Bus Adapter for Windows and Linux Installation Guide                                            13
About this Guide




14                 Host Bus Adapter for Windows and Linux Installation Guide
Introduction                                                                        1
                                                   1
                  This user guide provides information to help you install, configure, and use the
                  diagnostic utilities for the HP StorageWorks A7298A host bus adapter for
                  Windows and Linux platforms.


Overview
                  This introduction to the Host Bus Adapter (HBA) includes:
                  ■    Product Description
                  ■    Performance Specifications
                  ■    Boot BIOS Specifications
                  ■    Standards
                  ■    Agency Approvals




Host Bus Adapter for Windows and Linux Installation Guide                                            15
Introduction



Product Description
               The HBA has the following characteristics:
               ■   Robust suite of software supporting Windows Server 2003 and Linux Red Hat
                   Advanced Workstation v2.1.
               ■   Optical small form factor (LC) interface LC Fibre connector.
               ■   Embedded optical short-wave laser, multi-mode Fibre Channel interface.
               ■   Designed using a single custom Application Specific Integrated Circuit
                   (ASIC). The custom ASIC implements a very high performance, multi-class,
                   multi-protocol Fibre Channel host adapter with a 64-bit PCI or PCI-X bus
                   connection.
               ■   66/100/133MHz PCI-X 1.0a and PCI 2.2 compatibility.
               ■   266MIPs onboard processor, an embedded 1GB/2GB SERDES, and a high
                   performance unified QDR SRAM.
               ■   Controlled by a 266 MHz, 32-bit Intel StrongARM RISC processor.




16                                           Host Bus Adapter for Windows and Linux Installation Guide
Introduction




                  Figure 1: Host Bus Adapter


                  Table 2: Host Bus Adapter Diagram Description
                       Figure
                      Legend                                    Description
                          1          Fibre Channel (LC) connectors.
                          2          POST LEDs indicators
                                     Note: See Table 3 and Table 4 for detailed descriptions.




Host Bus Adapter for Windows and Linux Installation Guide                                                17
Introduction



Performance Specifications
               The PCI-X host bus adapter offers a highly integrated 2Gbps Fibre Channel HBA
               for use in servers based on either PCI or the latest PCI-X expansion bus. The
               features of this PCI-X based HBA provide the flexibility and broad
               interoperability needed for complex, highly scalable SANs.
               The HBA also features sophisticated hardware that provides superior performance
               in SANs and provides best in class server CPU offload. This exclusive hardware
               delivers low latency and high throughput in switched fabric, arbitrated loop, and
               clustered environments. Support for fiber optic cabling is provided through an
               embedded small form factor (LC) optical interface.
               The HBA is both ANSI Fibre Channel and PCI Local Bus Compliant and
               supports:
               ■   Simultaneous full duplex 2 Gbps PCI bus speed data transfers of 400 MBps
               ■   Full fabric support using F_PORT and FL_Port connections
               ■   Full fabric boot support in x86 environments to multiple LUNs
               ■   FC-Tape (FC-2) devices
               ■   Point-to-point arbitrated-loop, and switch fabric FC connections
               ■   Storage protocol
               ■   Fibre Channel class 2 and 3
               ■   Automatic speed negotiation and topology detection
               ■   End-to-end parity protection for high data integrity
               Collectively, these characteristics create a high-performance Fibre Channel HBA.




18                                            Host Bus Adapter for Windows and Linux Installation Guide
Introduction



Boot BIOS Specifications
                  Boot BIOS is a set of x86 instructions in the Host Bus Adapter (HBA) flash ROM
                  that lets you designate a Fibre Channel attached drive as the boot drive. Boot
                  BIOS works with the existing system BIOS on Intel Pentium class PCI system
                  boards.
                  Boot BIOS supports:
                  ■    Multiple topologies: Fabric Point-to-Point and FC-AL Private Loop
                  ■    Multiple boot compliance
                  ■    Supports Enhanced Disk Driver Services (EDD) Version 3.0
                  ■    A maximum of four Fibre Channel HBAs per server, depending on which
                       StorageWorks product you are using.
                  ■    Up to 256 LUNs, with up to eight LUN entries per target ID
                  ■    Detecting up to 99 devices per HBA
                  ■    Displaying a maximum of 16 devices during the boot process

Enabling Boot BIOS and External Boot
                  All HBAs have the BIOS firmware installed as a factory default. However, the
                  BIOS functionality is not enabled.
                  In addition, you can optionally eliminate server-based, internal boot devices and
                  boot from an external device to improve performance.
                  Refer to the BIOS Readme file on the HBA software kit as well as the
                  documentation for your StorageWorks product for the following up-to-date
                  information for enabling boot BIOS and external Boot:
                  ■    Enabling boot BIOS on an HBA
                  ■    Attaching HBAs in a supported configuration
                  ■    Enabling external boot for supported configurations
                  In addition, the HP website has the latest information on Boot BIOS upgrades.
                  Access the HP website at: http://www.hp.com/support/itaniumservers.




Host Bus Adapter for Windows and Linux Installation Guide                                           19
Introduction



Standards
               The HBA conforms to the following standards:
               ■   ANSI Fibre Channel FC-PH, Revision 4.3
               ■   ANSI Fibre Channel FC-AL, Revision 4.5
               ■   PCI Local Bus, Revisions 2.1 and 2.2
               ■   Fibre Channel Class 1, 2, 3




20                                               Host Bus Adapter for Windows and Linux Installation Guide
Introduction



Agency Approvals
                  The HBA has the following agency approvals:
                  ■    CFR Title 21, Laser AEL Class 1, FDA/CDRH
                  ■    UL recognized to UL1950
                  ■    CUR recognized to CSA22.2, No.950
                  ■    IEC 950 (1991) + Amendments 1, 2, 3, 4, and 11
                  ■    EN60950 (1992) + Amendments 1, 2, 3, 4, and 11
                  ■    EN68025-1 (1994) + Amendment 11
                  ■    EN68025-2 (1994)
                  ■    TUV certified to EN60950
                  ■    FCC Rules, CFR Title 47, Part 15, Subpart B, Class A
                  ■    Industry Canada, ICES-003, Class A
                  ■    EN55022 (1998)/CISPR22 (1997) Class A
                  ■    EN55024 (1998)
                  ■    European Union Low Voltage Directive 73/23/EEC
                  ■    CE-Marking Directive 93/68/EEC (CE Mark)
                  ■    EMC Directive 89/336/EEC (as amended by 92/31/EEC)
                  ■    Australian EMC Framework (C-Tick Mark)
                  ■    AS/NZS 3548:1995, Class A
                  ■    VCCI, Class A




Host Bus Adapter for Windows and Linux Installation Guide                              21
Introduction




22             Host Bus Adapter for Windows and Linux Installation Guide
Installation                                                                         2
                                                   2
Installation Overview
                  This chapter provides step-by-step instructions for installing the HP StorageWorks
                  A7298A Host Bus Adapter (HBA) including:
                  ■    Hardware Requirements
                  ■    Recording Reference Numbers
                  ■    Installing the HBA into a Computer
                  ■    Verifying the Installation
                  ■    Configuration Guidelines
                  This chapter also provides information on installation guidelines and supported
                  configurations for the operating systems.

                  IMPORTANT: The HBA contains static-sensitive components. Comply with Electrostatic
                  Discharge (ESD) procedures.




Host Bus Adapter for Windows and Linux Installation Guide                                           23
Installation



Hardware Requirements
               The system hardware requirements for installing the HBA include:
               ■   A host computer that provides 3.3VDC PCI and PCI-X bus power
               ■   One open 64-bit 33/66 MHz PCI or 66/100/133 MHz PCI-X bus slot with
                   either a 3.3 or a 5.0 VDC signaling interface
               ■   Multimode fiber optic cable with LC connector, used with short-wave lasers




24                                           Host Bus Adapter for Windows and Linux Installation Guide
Installation



Recording Reference Numbers
                  Each HBA ships with a unique address identifier that is stored in flash memory.
                  Fibre Channel industry standards issue two unique identifiers: WorldWide Port
                  Name (WWPN) and Node Name (NN), each of which is derived from the HBA’s
                  IEEE address. Combined, the WWPN and NN create the WorldWide Name
                  (WWN) which is an 8-byte field that uniquely identifies an HBA on a FC circuit.
                  The WWN address and serial number are clearly marked on the HBA. Record the
                  addresses on the lines below for future reference.


                  Note: The WWN is a static identifier that cannot be changed.


                  IEEE address: __________________________________________________
                  Serial number: __________________________________________________




Host Bus Adapter for Windows and Linux Installation Guide                                        25
Installation



Installing the HBA into a Computer
               Following is the procedure for installing the HBA into a computer.


                       WARNING: Be sure to observe the ESD precautions for this procedure.



               1. Make sure the computer is powered off.
               2. Remove the screws on the computer cover, and then remove the cover.
               3. Wearing a static wrist strap, remove the blank panel from an empty 64-bit PCI
                  or PCI-X bus slot.
                   Compare the removed panel to the bracket on the host bus adapter. Follow
                   steps 4-7 to change the bracket if they are different sizes.


                  Note: The host bus adapter comes with a standard PCI bracket installed. The
                  low-profile mounting bracket is shorter than the standard bracket; approximately
                  3.11 in. (7.9cm) compared to 4.75 in. (12.06 cm) long.


               4. Remove the mounting bracket screws from the top of the host bus adapter.
               5. Remove the bracket and store it for future use.
               6. Align the new mounting bracket tabs with the holes in the HBA.


                   Note: Be careful not to push the bracket past the transceiver housing's grounding
                   tabs.


               7. Replace the screws that attach the HBA to the bracket.
               8. Insert the HBA into the empty PCI or PCI-X bus slot; press firmly until it is
                  seated securely.
               9. Secure the HBA mounting bracket to the computer panel with the panel
                  screws.
               10. Replace the computer cover and secure it using the previously removed
                   screws.



26                                             Host Bus Adapter for Windows and Linux Installation Guide
Installation



                  11. Attach media:
                       a. Connect the fiber optic cable to the LC connector on the HBA.
                       b. Connect the other end of the cable to the Fibre Channel device.


                           Note: The HBA does not allow normal data transmission on an optical link
                           unless it is connected to a similar or compatible laser product. That is, both
                           products are multimode to multimode.




Host Bus Adapter for Windows and Linux Installation Guide                                                   27
Installation



Verifying the Installation
               To verify the HBA is properly installed and is operating:
               1. Turn on the computer.
               2. At power up, observe the POST LED indicators on the HBA. The position of
                  the POST LED indicators is defined in Figure 1 and Table 2 of this guide. The
                  green LED indicates power functions and the amber LED signifies port
                  activity. The amber LED blinks at all times during normal operation. Table 3
                  lists normal LED indications.
               Table 3: Normal POST LED Indicators
                  Amber LED (L1)         Green LED (L2)                       State
                Off                     Off                  Wake-up failure (dead board)
                On                      Off                  POST failure (dead board)
                Slow blink (1 Hz)       Off                  Wake-up failure (dead board)
                Fast blink (4 Hz)       Off                  Failure in POST (dead board)
                Flashing (irregular)    Off                  POST processing in progress
                Off                     On                   Failure while functioning
                On                      On                   Failure while functioning
                Slow blink (1 Hz)       On                   Normal—1 Gb link rate
                Fast blink (4 Hz)       On                   Normal—2 Gb link rate
                Off                     Blink (1 Hz)         Normal—link down or not yet started




28                                            Host Bus Adapter for Windows and Linux Installation Guide
Installation



Configuration Guidelines
                  The software for loading the driver also contains the default registry parameter
                  settings that are loaded as part of the driver installation. Consult the following
                  sources for any restriction and for information on supported configurations
                  specific to your operating system and topology.
                  ■    Release Notes
                  ■    HP Website at: http://www.hp.com/support/itaniumservers.




Host Bus Adapter for Windows and Linux Installation Guide                                              29
Installation




30             Host Bus Adapter for Windows and Linux Installation Guide
Installing the SCSI Miniport
Driver
                                                                                          3
                                                   3
Introduction
                  This chapter contains step-by-step instructions for installing the Windows Server
                  2003 and Linux SCSI Miniport drivers.
                  System managers must be familiar with the operating system under which the PCI
                  or PCI-X-to-Fibre Channel Host Bus Adapter (HBA) is to operate. System
                  managers must also have access to standard system documentation.
                  The software kit that is included with the HBA contains the latest version of the
                  HBA’s files and drivers at the time of shipment. Software files are updated
                  periodically and can be obtained from the HP website at:
                  http://www.hp.com/support/itaniumservers.


                  Note: This chapter describes the steps for installing the device driver and for accessing
                  Fibre Channel storage devices. For other configuration changes, see Chapter 5, Modify
                  Diagnostic Driver Parameters in the Windows Registry.




Host Bus Adapter for Windows and Linux Installation Guide                                                31
Installing the SCSI Miniport Driver



Windows Server 2003 Device Driver Installation
                   This section describes the instructions for installing the Windows Server 2003
                   SCSI Miniport driver.

Windows Server 2003 System Requirements
                   Ensure that your system meets these minimum requirements:
                   ■    Installed HBA
                   ■    Ensure the HP Setup and Configuration CD for Itanium(R) 2-based servers is
                        in the server or the driver has been downloaded from the web and copied to
                        the server hard drive.
                   ■    StorageWorks Fibre Channel Storage subsystem (interconnect device and
                        storage device)

Installing the Windows Server 2003 SCSI Miniport Driver
                   This section contains the steps for installing the Windows Server 2003 SCSI
                   Miniport device driver on a Windows Server 2003.
                   From the Windows Server 2003 desktop:
                   1. Click Start > Settings > Control Panel.
                   2. Double-click Administrative Tools.
                   3. Double-click Computer Management.
                   4. Click Device Manager.
                   5. Open the SCSI and RAID controllers item in the list.
                   6. Choose the Drivers tab.
                   7. Choose Update Driver.
                   8. Choose Install the software automatically (Recommended) and click Next.
                   9. Click Finish.
                   10. Click Yes to restart Windows Server 2003.
                   11. Verify the device driver installation:
                        a. Click Start > Settings > Control Panel.
                        b. Double-click the System icon.
                        c. Click Device Manager.


32                                                 Host Bus Adapter for Windows and Linux Installation Guide
Installing the SCSI Miniport Driver



                       d. Verify that the SCSI Miniport driver is present and started.

Removing the Windows Server 2003 SCSI Device Driver
                  To remove the device driver from the Windows Server 2003 desktop:
                  1. Click Start > Settings > Control Panel.
                  2. Double-click the System icon.
                  3. Click Device Manager.
                  4. Open the SCSI and RAID controllers item in the list.
                  5. Click Remove.
                  6. Choose Yes to confirm.
                  7. Click OK.
                  8. Reboot the computer to restart Windows Server 2003.




Host Bus Adapter for Windows and Linux Installation Guide                                               33
Installing the SCSI Miniport Driver



Linux Device Driver Installation
                   This section describes the instructions for installing the Linux SCSI Miniport
                   driver.

Linux System Requirements
                   Ensure that your system meets these minimum requirements:
                   ■    Installed HBA
                   ■    Linux Miniport driver and registry parameter file from the software kit
                        provided with the HBA
                   ■    Linux operating system
                   ■    StorageWorks Fibre Channel Storage subsystem (interconnect device and
                        storage device)




34                                                 Host Bus Adapter for Windows and Linux Installation Guide
Installing the SCSI Miniport Driver



Installing the Linux Driver Using a Tar File
                  To install the driver and boot the system, you must be running as root.
                  1. Enter the following command to create a temporary directory (for example,
                     emlxtemp).
                       # mkdir emlxtemp
                  2. Enter the following command to change directory to the temporary directory.
                       # cd emlxtemp
                  3. Copy or download the device driver file to the temporary directory.
                  4. Enter the following command if the file is in the format filename.rpm.Z:
                       # tar xvzf        filename.tar.Z
                       or else untar the driver file.
                       # tar xvf       filename.tar
                       The package unzips to one SourceBuild directory.
                  5. Enter the following command to change directory to the SourceBuild
                     directory.
                       # cd SourceBuild
                       This becomes the driver_installation_directory.




Host Bus Adapter for Windows and Linux Installation Guide                                                35
Installing the SCSI Miniport Driver



Installing the Linux Driver Using an RPM File
                   To install the driver and boot the system, you must be running as root.
                   1. Enter the following command to create a temporary directory (for example,
                      emlxtemp).
                        # mkdir emlxtemp
                   2. Enter the following command to change directory to the temporary directory.
                        # cd emlxtemp
                   3. Copy or download the device driver RPM file to the temporary directory.
                   4. Enter the following command if the file is in the format filename.rpm.Z and
                      kernel source files are installed:
                        # uncompress filename.rpm.Z
                   5. Enter the following command to install the driver into
                      /usr/src/linux/drivers/scsi/lpfc, the driver_installation_directory.
                        # rpm -i filename.rpm
                   6. Enter the following command to install the driver into
                      /usr/src/<kernelsource>/drivers/scsi/lpfc, the driver_installation_directory.
                        # rpm -i --prefix /usr/src/<kernelsource>/drivers/scsi/lpfc
                        filename.rpm
                        If the prefix option is used you must update BASEINCLUDE in the Makefile
                        placed in the installation directory.
                   7. Enter the following command to verify that the RPM installation was
                      successful:
                        # rpm -a -q | grep lpfc
                   8. Enter the following command to remove the RPM type:
                        # rpm -e rpm_name
                   9. Enter the following command to change directory to
                      driver_installation_directory.
                        # cd /usr/src/<kernelsource>/drivers/scsi/lpfc




36                                                 Host Bus Adapter for Windows and Linux Installation Guide
Installing the SCSI Miniport Driver



Building the Driver as a Module
                  Once you have installed the source file, you can build the driver as a module.
                  1. At the shell prompt, edit lpfc.conf.c to reflect your desired configuration.
                  2. Enter the following command to verify that both kernel-headers and
                     kernel-source RPMs are installed:
                       # rpm -a -q | grep kernel
                  3. Enter the following command to install the kernel-headers and kernel-source
                     RPMs if they are not installed:
                       # rpm -i kernel-headers*
                       # rpm -i kernel-source*


                       Note: Red Hat Version 7.3 does not recognize kernel headers. Kernel headers is
                       replaced by glibc_kernelheaders.rpm.


                       By default, the driver looks for the kernel source under /usr/src/linux. If the
                       source resides under a different directory, there are two ways to enable the
                       driver to locate the kernel source.
                  4. Enter the following command if the kernel source resides in
                     /usr/src/<kernelsource>:
                       # ln -sf /usr/src/<kernelsource> /usr/src/linux
                       A directory listing similar to the following displays:
                       lrwxrwxrwx1rootroot11Aug 2 13:51 linux -> linux-2.4.4
                       drwxr-xr-x14 1046     101 4096Aug 2 13:51 linux-2.4.4
                       Or change the BASEINCLUDE variable in Makefile to point to the correct
                       location. For example:
                       BASEINCLUDE = /usr/src/kernelsource
                  5. Enter the following command to verify the kernel type (SMP or non-SMP):
                       # uname -r
                  6. Only for non-SMP kernel module (i386 platform only), edit the Makefile and
                     delete the following text:
                       -D__SMP__=1 




Host Bus Adapter for Windows and Linux Installation Guide                                                 37
Installing the SCSI Miniport Driver



                        The edited text should now display as follows:
                        # For 32-bit    environment
                        # If this is    not a SMP environment remove the -D__SMP__=1 from
                        CFLAGSCFLAGS    = -D__KERNEL__=1 
                           $[MODINC]    $[INCLUDEDIR]
                   7. For SuSE Linux, enter the following ifconfig command (all on one line):
                        # cp /boot/vmlinuz.version.h
                        /lib/modules/'uname-r'/build/include/linux/version.h
                   8. Enter the following command to build the drivers:
                        # make build
                        This will create the driver files similar to the following:
                        -rw-r--r--       1 root      root     226200 Aug 13 10:33 lpfcdd.2.4.4.o
                        -rw-r--r--       1 root       root     3334 Aug 13 10:33 lpfndd.2.4.4.o
                   9. Enter the following command to install both drivers under
                      /lib/modules/kernel_version:
                        # make install




38                                                  Host Bus Adapter for Windows and Linux Installation Guide
Installing the SCSI Miniport Driver



Loading the Driver
                  There are two ways to load the driver: manually or through the RAM disk image.

Loading the Driver Manually
                  1. Enter the following commands:
                       # insmod lpfcdd
                       # insmod lpfndd
                       lpfcdd - main driver, SCSI functionality, FCP support, diagnostic support
                       lpfndd - IP support (this driver is dependent on lpfcdd being loaded first)
                  2. Enter the following command to bring up the interface:
                       Edit /etc/sysconfig/network-scripts/ifcfg-lpfnX.
                  3. On SuSE, run the ifconfig command (all on one line) to configure the
                     interface:
                       insmod lpfndd
                       ifconfig lpfn X inet 172.16.0.1 netmask 255.255.255.0
                       broadcast 199.199.255.255
                       Where X is the interface number, 0 through 7. This file should be created if
                       you wish to configure IP. An example of this file:
                       DEVICE=lpfn0IPADDR=138.239.40.6
                       BROADCAST=138.239.40.255
                       NETWORK=138.239.40.0
                       NETMASK=255.255.255.0
                       ONBOOT=yes
                  4. Enter the following command to manually bring up the IP interface:
                       ifup lpfnX
                       Where X is the interface number, 0 through 7.
                  5. Enter the following commands if the system does not have a SCSI driver
                     loaded:
                       # insmod scsi_mod
                       # insmod sd_mod
                       Rebooting the system will unload the driver. You should include the above
                       commands in a start up script to automatically load the driver.




Host Bus Adapter for Windows and Linux Installation Guide                                                39
Installing the SCSI Miniport Driver



Loading the Driver Through the RAM Disk Image
                   1. To add SCSI and IP modules, edit /etc/conf.modules or modules.conf,
                      depending on the Linux release.
                        Add the following line to add a SCSI module:
                        alias scsi_hostadapter lpfcdd
                        Add the following line to add an IP module:
                        alias lpfnX lpfndd
                        where X is the interface number, 0 through 7.


                         Note: If you want to configure SCSI only, just add the scsi_hostadapter line. The IP
                         module is dependent on the SCSI modules being there, so you cannot configure
                         just IP.


                   2. Run the following command to update your system with the information you
                      added to /etc/conf.modules:
                        # depmod -a
                        Edit /etc/sysconfig/network-scripts/ifcfg-lpfnX.
                        Where X is the interface number, 0 through 7. This file should be created if
                        you wish to configure IP. An example of this file:
                        DEVICE=lpfn0
                        IPADDR=138.239.40.6
                        BROADCAST=138.239.40.255
                        NETWORK=138.239.40.0
                        NETMASK=255.255.255.0
                        ONBOOT=yes
                        SuSE does not use the above structure.
                   3. Run the following script (all on one line) once lpfcdd is loaded to bring up IP:
                        insmod lpfndd ifconfig lpfxdd inet n.n.n.n. broadcast n.n.n.n
                        netmaskn.n.n.n.
                        Edit /etc/lilo.conf to specify boot / startup parameters. Keep a boot image
                        record that is known to be good, so you can boot the system in case of
                        problems. A boot image record consists of lines between
                        “image=kernel_version” entries. An example of a default /etc/lilo.conf:
                        boot=/dev/sda
                        map=/boot/map
                        install=/boot/boot.bprompt


40                                                    Host Bus Adapter for Windows and Linux Installation Guide
Installing the SCSI Miniport Driver


                       timeout=50
                       default=linux
                       image=/boot/vmlinuz-kernel_version
                       label=linux
                       root=/dev/sda8
                       initrd=/boot/initrd-kernel_version.imgread-only
                  4. Add the following lines to the end of the file to add a new boot record for the
                     driver:
                       image=/boot/vmlinuz-kernel_version
                       label=new_label
                       root=/dev/sda8
                       initrd=/boot/new_image_filenameread-only
                       append=”max_scsi_luns=128”


                       Note: Currently, lpfc is not supported as the root device, so keep the
                       “root=/dev/xxx” parameter the same.


                  5. Add the following line to get multiple LUN support:
                       append=”max_scsi_luns=LUNs”
                       Where LUNs is the number of LUNs per SCSI device. Adding this line is
                       optional.
                  6. Run these commands to build the boot image. The boot image
                     new_image_name must match the name specified in the /etc/lilo.conf file:
                       # rm -f /boot/new_image_filename
                       # /sbin/mkinitrd /boot/new_image_filename kernel_version
                  7. Run these commands to check and load the boot image:
                       # lilo -t -v
                       # lilo -v
                  8. Reboot the system to incorporate the new driver. At the shell prompt, enter the
                     following:
                       # sync
                       # reboot
                  9. As the system reboots, you are prompted with LILO boot. At this point enter
                     the name of the label of your boot image, new_label in the above example, or
                     just press enter and the default boot image will be loaded.




Host Bus Adapter for Windows and Linux Installation Guide                                                   41
Installing the SCSI Miniport Driver



Building the Driver Into the Kernel

SCSI Functionality
                   Once you have installed the source files, you can build the driver into the kernel.
                   1. Enter the following commands:
                        #   mkdir /usr/src/linus/scsi/lpfc
                        #   find . -print | cpio -pdumv /usr/src/linux/drivers/scsi/lpfc
                        #   cd /usr/src/linux/drivers/scsi/lpfc
                        #   cp Makefile.kernel Makefile
                   2. Edit the Makefile and the lpfc.conf.c files, if needed.
                   3. Enter the following command to change the directory to the Linux source:
                        # cd /usr/src/linux/
                   4. Edit Rules.make and remove “$(sort and the matching closing parenthesis
                      from this line:
                        subdir-list = $(sort $(patsubst %,_subdir_%,$(SUB_DIRS)))
                        The edited line should now display as follows:
                        subdir-list = $(patsubst %,_subdir_%,$(SUB_DIRS))


                        Note: For some 2.4 based kernels, this will allow the scsi/lpfc Makefile to be
                        invoked BEFORE the scsi Makefile.


                   5. Edit the Makefile under the drivers directory:
                        # cd /usr/src/linux/drivers
                        # vi Makefile
                   6. Add a check for $(CONFIG_SCSI_LPFC) to add scsi/lpfc to the directory
                      lists before $(CONFIG_SCSI) adds scsi to the directory lists. The scsi/lpfc
                      Makefile should be invoked BEFORE the scsi Makefile. Edit the following
                      lines:
                        subdir-$(CONFIG_IDE) += ide
                        subdir-$(CONFIG_SCSI) += scsi
                   7. Add the following line:
                        subdir-$(CONFIG_SCSI_LPFC) += scsi/lpfc




42                                                   Host Bus Adapter for Windows and Linux Installation Guide
Installing the SCSI Miniport Driver



                       The edited lines should now display as follows:
                       subdir-$(CONFIG_IDE) += ide
                       subdir-$(CONFIG_SCSI_LPFC) += scsi/lpfc
                       subdir-$(CONFIG_SCSI) += scsi
                  8. Go to the scsi directory:
                       # cd /usr/src/linux/drivers/scsi
                       Edit Config.in and locate the following lines (the lines may wrap.):
                       dep_tristate 'EATA-PIO [old DPT PM2001, PM2012A] support'
                       CONFIG_SCSI_EATA_PIO $CONFIG_SCSI
                       dep_tristate 'Future Domain 16xx sCSI/AHA-2920A support'
                       CONFIG_SCSI_FUTURE_DOMAIN $CONFIG_SCSI
                  9. Add the following line (in alphabetical order):
                       dep_tristate 'Emulex LightPulse Fibre Channel support'
                       CONFIG_SCSI_LPFC $CONFIG_SCSI
                       The edited lines should now display as follows.
                       dep_tristate 'EATA-PIO [old DPT PM2001, PM2012A] support'
                       CONFIG_SCSI_EATA_PIO $CONFIG_SCSI
                       dep_tristate 'Emulex LightPulse Fibre Channel support'
                       CONFIG_SCSI_LPFC $CONFIG_SCSI
                       dep_tristate 'Future Domain 16xx sCSI/AHA-2920A support'
                       CONFIG_SCSI_FUTURE_DOMAIN $CONFIG_SCSI
                  10. Edit Makefile and add (with other CONFIG_SCSI_devices) a check for
                      $(CONFIG_SCSI_LPFC), if defined. Add lpfcdd.o to the object list.
                  11. Locate the following lines:
                       obj-$(CONFIG_SCSI_IPS) += ips.o
                       obj-$(CONFIG_SCSI_FD_MCS) += fd_mcs.o
                       obj-$(CONFIG_SCSI_FUTURE_DOMAIN)+= fdomain.o
                  12. Add the following line:
                       obj-$(CONFIG_SCSI_LPFC) += lpfcdd.o
                       The edited lines should now display as follows.
                       obj-$(CONFIG_SCSI_IPS) += ips.o
                       obj-$(CONFIG_SCSI_LPFC) += lpfcdd.o
                       obj-$(CONFIG_SCSI_FD_MCS) += fd_mcs.o
                       obj-$(CONFIG_SCSI_FUTURE_DOMAIN)+= fdomain.o
                  13. For some 2.2 based kernels, edit hosts.c. Add the following lines:
                       #ifdef CONFIG_SCSI_LPFC
                       #include “lpfc/include/fc_os.h”
                       #endif




Host Bus Adapter for Windows and Linux Installation Guide                                                43
Installing the SCSI Miniport Driver



                   14. At the end of the definition for Scsi_Host_Template, before “Removable host
                       adapters”, add the following lines:
                        #ifdef CONFIG_SCSI_LPFC
                           EMULEXFC,
                        #endif


IP Functionality
                   1. Go to the net directory:
                        # cd /usr/src/linux/drivers/net
                   2. Edit Config.in. Edit the following lines:
                        bool 'Fibre Channel driver support' CONFIG_NET_FC
                        if [“$CONFIG_NET_FC” = “y”]; then
                           dep_tristate' Interphase 5526 Tachyon chipset based adapter
                        support' CONFIG_IPHASE5526 $CONFIG_SCSI$CONFIG_PCI
                        fi
                   3. Add the following line (all one line):
                        dep_tristate ' Emulex LightPulse Fibre Channel support'
                        CONFIG_NET_LPFC $CONFIG_SCSI $CONFIG_PCI
                        The edited lines should now display as follows:
                        bool 'Fibre Channel driver support' CONFIG_NET_FC
                        if [“$CONFIG_NET_FC” = “y”]; then
                           dep_tristate' Interphase 5526 Tachyon chipset based adapter
                        support' CONFIG_IPHASE5526 $CONFIG_SCSI$CONFIG_PCIdep_tristate
                        ' Emulex LightPulse Fibre Channel support' CONFIG_NET_LPFC
                        $CONFIG_SCSI $CONFIG_PCI
                        fi
                   4. Locate the following text in Space.c:
                        #ifdef CONFIG_NET_FC
                        static int fcif_probe(struct net_device *dev)
                        {
                        if (dev->base_addr == -1)
                        return 1;
                        if (1
                        #ifdef CONFIG_IPHASE5526
                               && iph5526_probe(dev)
                        #endif
                               && 1) {
                        return 1; /* -ENODEV or -EAGAIN would be more accurate. */
                           }
                        return 0;
                        }
                        #endif /* CONFIG_NET_FC */



44                                                Host Bus Adapter for Windows and Linux Installation Guide
Installing the SCSI Miniport Driver



                  5. Add this text after #ifdef CONFIG_NET_FC:
                       static int lpfnif_probe(struct net_device *dev){
                       #ifdef CONFIG_LPFC_SCSI
                       lpfn_probe();
                       #endif
                       return 0;
                       }
                       The edited lines should now display as follows:
                       #ifdef CONFIG_NET_FC
                       static int lpfnif_probe(struct net_device *dev)
                       {
                       #ifdef CONFIG_LPFC_SCSI
                       lpfn_probe();
                       #endif
                       return 0;
                       }
                       static int fcif_probe(struct net_device *dev)
                       {
                       if (dev->base_addr == -1)
                       return 1;
                       if (1
                       #ifdef CONFIG_IPHASE5526
                       && iph5526_probe(dev)
                       #endif
                       && 1) {
                       return 1; /* -ENODEV or -EAGAIN would be more accurate. */
                       }
                       return 0;
                       }
                       #endif /* CONFIG_NET_FC */}
                  6. Locate the following lines:
                       #ifdef CONFIG_NET_FC
                       static struct net_device fc1_dev = {
                       “fc1”, 0, 0, 0, 0, 0, 0, 0, 0, 0, NEXT_DEV, fcif_probe};
                       static struct net_device fc0_dev = {
                       “fc0”, 0, 0, 0, 0, 0, 0, 0, 0, 0, &fc1_dev, fcif_probe};
                       # undef NEXT_DEV
                       # define NEXT_DEV (&fc0_dev)
                       #endif
                  7. Add these lines after: # define NEXT_DEV (&fc0_dev):
                       static struct net_device lpfn_dev = {
                       “lpfn”, 0, 0, 0, 0, 0, 0, 0, 0, 0, NEXT_DEV, lpfnif_probe};
                       # undef NEXT_DEV
                       # define NEXT_DEV (&lpfn_dev)
                       The edited lines display as follows:
                       #ifdef CONFIG_NET_FC
                       static struct net_device fc1_dev = {



Host Bus Adapter for Windows and Linux Installation Guide                                                45
Installing the SCSI Miniport Driver


                        “fc1”, 0, 0, 0, 0, 0, 0, 0, 0, 0, NEXT_DEV, fcif_probe};
                        static struct net_device fc0_dev = {
                        “fc0”, 0, 0, 0, 0, 0, 0, 0, 0, 0, &fc1_dev, fcif_probe};
                        # undef NEXT_DEV
                        # define NEXT_DEV (&fc0_dev)static struct net_device lpfn_dev =
                        {
                        “lpfn”, 0, 0, 0, 0, 0, 0, 0, 0, 0, NEXT_DEV, lpfnif_probe};
                        # undef NEXT_DEV
                        # define NEXT_DEV (&lpfn_dev)
                        #endif
                   8. Follow the normal procedures for building the Linux kernel and include all
                      Emulex LightPulse Fibre Channel support:
                        # cd /usr/src/linux
                        # make mrproper
                        # make menuconfig
                   9. Choose 'Emulex LightPulse Fibre Channel support' under SCSI low level
                      drivers for FCP support.
                   10. Choose “Fibre Channel driver support” “Emulex LightPulse Fibre Channel
                       support” under Network Drive support for IP support.
                   11. Choose any other options that may be required.
                   12. Build the new kernel and modules:
                        #   make      dep
                        #   make      clean
                        #   make      install
                        #   make      modules
                        #   make      modules_install
                   1. Edit lilo.conf to reflect the new kernel and run mkinitrd and lilo as explained
                      in the procedure for Building the Driver as a Module.
                   2. Reboot with the new kernel.




46                                                      Host Bus Adapter for Windows and Linux Installation Guide
Installing the SCSI Miniport Driver



Setting up and Running Diagnostic Utilities
                  1. Go to the driver source directory.
                       # cd driver_installation_directory
                  2. Enter one of the following commands to run the diagnostic utilities:
                       # ./lputil
                       or
                       # ./dfc


Installing the Latest Version of HBA API and Utilities
                  1. Enter the following command to install the latest version of HBA API and
                     utilities:
                       # sh Install.sh




Host Bus Adapter for Windows and Linux Installation Guide                                             47
Installing the SCSI Miniport Driver




48                                    Host Bus Adapter for Windows and Linux Installation Guide
Troubleshooting                                                                    4
                                                   4
Introduction
                  The Power-On Self Test (POST) and the Windows Event Viewer are
                  troubleshooting utilities you can use for the Host Bus Adapter (HBA). This
                  chapter explains the use of these utilities in the event of an HBA problem.




Host Bus Adapter for Windows and Linux Installation Guide                                       49
Troubleshooting



POST Conditions and Results
                  Table 4 lists the HBA LED states with descriptions of each.The position of the
                  POST LED indicators is defined in Figure 1 and Table 2 of this guide.
                  If the LEDs indicate a failure during POST:
                  1. Make sure that the HBA is seated firmly in the PCI slot.
                  2. Verify that the fibre cable connection to the HBA is secure.
                  Table 4: Normal POST LED Indicators
                     Amber LED (L1)        Green LED (L2)                        State
                   Off                     Off                  Wake-up failure (dead board)
                   On                      Off                  POST failure (dead board)
                   Slow blink (1 Hz)       Off                  Wake-up failure (dead board)
                   Fast blink (4 Hz)       Off                  Failure in POST (dead board)
                   Flashing (irregular)    Off                  POST processing in progress
                   Off                     On                   Failure while functioning
                   On                      On                   Failure while functioning
                   Slow blink (1 Hz)       On                   Normal—1 Gb link rate
                   Fast blink (4 Hz)       On                   Normal—2 Gb link rate
                   Off                     Blink (1 Hz)         Normal—link down or not yet started




50                                               Host Bus Adapter for Windows and Linux Installation Guide
Troubleshooting



Using The Event Viewer
                  The Windows SCSI driver verifies the condition of the HBA POST. If there is a
                  failure or a suspected failure, an error log entry is issued to the Windows Event
                  log.
                  Following is the procedure for viewing the event log.
                  From the Main menu:
                  1. Double-click or choose the Administrative Tools program group.
                  2. Double-click or choose the Event Viewer. The display shows a list of discrete
                     events specifying the source name:
                       ■   For Windows NT, specify LPGNDS35
                       ■   For Windows 2000 or Windows Server 2003, specify CPQKGPSA.
                  3. Double-click any event with the source name.
                  4. Change the data view from Bytes (default) to Words.
                  5. Examine the entry at offset 0x10: if the low byte = En, match the low byte
                     with the error found in Table 5, Windows NT SCSI Port Error Log. Table 6
                     and Table 7 list CmdStat values and Parameter error values.




Host Bus Adapter for Windows and Linux Installation Guide                                             51
Troubleshooting



Windows Miniport Event Log Codes
                  The Windows Miniport driver logs events and errors in the Windows Event log.
                  Serious errors are always logged. Informational events are only logged if the
                  registry parameter LogError=1 is used.
                  All Miniport logged events are issued with an Event ID of 11 (INTERNAL
                  ADAPTER ERROR) but do not necessarily indicate an HBA error occurred. Byte
                  offset 0x10 of the event is the driver event code. Byte offsets 0x11 to 0x13 contain
                  event-specific information.
                  Table 5 describes the SCSI port error log codes
                  Table 5: SCSI Port Error Log Codes
                    0x10                                                 0x11 to 0x13 Further
                    Offset             Explanation                           Information
                   0xC0       Invalid Link Speed Selection
                              (Windows NT)
                   0xD0       SNS_REQ (XMIT_SEQ failed)           0x11 = cmdstat, 12 = parm err
                   0xD1       SNS_RSP (RCV_SEQ failed)            0x11 = cmdstat, 12 = parm err
                   0xD3       RCV_ELS_REQ failed                  0x11 = cmdstat, 12 = parm err
                   0xD4       XMT_ELS_REQ failed                  0x11 = cmdstat, 12 = parm err
                   0xD5       Too many targets found (160+)       0x11 to 13 = D_DID that didn’t fit
                   0xD6       SNS request time-out                0x11 to 13 no additional
                                                                  information
                   0xD7       Mailbox interrupt time-out          0x11 = mailbox word 0
                   0xD8       TPRLO requested when busy           0x11 = local req. state, 12 =
                                                                  discstate, 13 = mailbox word 0
                   0xD9       Link down time-out occurred         0x11 = local req. state, 12 =
                                                                  discstate, 13 = mailbox word 0
                   0xDA       Hard link down time-out             0x11 = local req. state, 12 =
                              occurred                            discstate, 13 = mailbox word 0
                   0xE0       Node purged from configuration      0x11 to 0x13 = D_ID of node
                              (Windows NT)                        purged
                   0xE1       Error interrupt occurred            Status register bytes 1-3 in event
                                                                  11-13. E1 error indicates an HBA
                                                                  hardware failure, return HBA for
                                                                  repair.


52                                                 Host Bus Adapter for Windows and Linux Installation Guide
Troubleshooting



                  Table 5: SCSI Port Error Log Codes (Continued)
                    0x10                                                   0x11 to 0x13 Further
                    Offset                Explanation                          Information
                   0xE2         Mailbox cmd time-out                0x11 = command
                   0xE3         Mailbox rsp err                     0x11 = command, 12-13 =
                                                                    mbxstatus
                   0xE4         HBA not ready after init            Status register bytes 1-3 in event
                                                                    11-13
                   0xE5         Requested loop but link = PT-PT
                   0xE6         Mailbox int. but cmd not            0x11 = MB cmd, 12-13 = mbxstatus
                                complete
                   0xE7         SRB already queued to ring
                   0xE8         RESTART failed
                   0xE9         PORT BYPASS (LPB) received
                   0xEB         Unknown IOCB cmd rsp                0x11 = 15:8 = cmd field
                   0xEC         Uncached extension alloc. Error
                   0xED         Link down @ boot time (30 sec)
                   0xEF         Too many interrupts at initial
                                boot
                   0xF0         Rcv ELS request (possible logout)   0x11 = ELS type, 12-13 = X_ID
                                (Windows NT)
                   0xF1         LinkUp error; LP8 down, driver      0x11 = parameter field, 12 = IOCB
                                up                                  cmd
                   0xF2         LinkUp w/ illegal or corrupt RPI    0x11 = parameter field, 12 = IOCB
                                                                    cmd
                   0xF3         DeQueue ring->iotcmd.head           0x11 = caller ID
                   0xF4         HBA reset                           0x11 = coded reason for reset:
                                                                    Bit 0 = IOCB requeue; bit 1 = readla
                                                                    retry
                                                                    Bit 2 = initlink retry; bit 3 = rstbus
                                                                    retry
                                                                    Bit 4 = mailbox time-out
                   0xF5         PCP_IXXX_CR IOCB rsp err            0x11 = cmdstat, 12 = parm err, 13 =
                                                                    ALPA


Host Bus Adapter for Windows and Linux Installation Guide                                                    53
Troubleshooting



                  Table 5: SCSI Port Error Log Codes (Continued)
                    0x10                                                0x11 to 0x13 Further
                    Offset             Explanation                          Information
                   0xF6       PCP_IXXX_CR IOCB rsp err           0x11 = cmdstat, 12 = parm err, 13 =
                                                                 ALPA
                   0xF7       Ring hd !=0 &&
                              pendingsrb!=NULL
                   0xF8       Invalid FCP_RSP                    0x11 = pcpcntrl, 12 = scsisat, 13 =
                                                                 len
                   0xF9       Two consec. time-outs, issue LIP
                   0xFA       START_IO error                     0x11 = errtype, 12 = srbstat, 13 =
                                                                 linkup
                   0xFB       ELS_REQ_CR IOCB rsp err            0x11 = cmdstat, 12 = parm err, 13 =
                                                                 ALPA
                   0xFC       ELS_REQ_CR IOCB rsp err            0x11 = cmdstat, 12 = parm err, 13 =
                                                                 ALPA
                   0xFE       FLOGI failed                       0x11 = cmdstat, 12 = parm err
                   0xFF       SNS_PLOGI failed                   0x11 = cmdstat, 12 = parm err

                  Table 6: CmdStat Values
                    0x11
                    Offset                Explanation                       Further Information
                   0x1         IOSTAT_FCP_RSP_ERR
                   0x2         IOSTAT_REMOTE_STOP                     Remote sent an ABTS
                   0x3         IOSTAT_LOCAL_REJECT                    Parameter field contains
                                                                      additional information
                   0x4         IOSTAT_NPORT_RJT
                   0x5         IOSTAT_FABRIC_RJT
                   0x6         IOSTAT_NPORT_BSY
                   0x7         IOSTAT_FBRIC_BSY
                   0x8         IOSTAT_INTERMED_RSP
                   0x9         IOSTAT_LS_RJT
                   0xA         IOSTAT_BA_RJT



54                                                Host Bus Adapter for Windows and Linux Installation Guide
Troubleshooting




                  Table 7: Parameter Error Values Valid only when CmdStat=0x3
                     0x12 Offset                               Explanation
                   0x00                  IOERR_SUCCESS
                   0x01                  IOERR_MISSING_CONTINUE
                   0x02                  IOERR_SEQUENCE_TIMEOUT
                   0x03                  IOERR_INTERNAL_ERROR
                   0x04                  IOERR_INVALID_RPI
                   0x05                  IOERR_NO_XRI
                   0x06                  IOERR_ILLEGAL_COMMAND
                   0x07                  IOERR_XCHG_DROPPED
                   0x08                  IOERR_ILLEGAL_FIELD
                   0x09                  IOERR_BAC_CONTINUE
                   0x0A                  IOERR_TOO_MANY_BUFFERS
                   0x0B                  IOERR_RCV_BUFFER_WAITING
                   0x0C                  IOERR_NO_CONNECTION
                   0x0D                  IOERR_TX_DMA_FAILED
                   0x0E                  IOERR_RX_DMA_FAILED
                   0x0F                  IOERR_ILLEGAL_FRAME
                   0x10                  IOERR_EXTRA_DATA
                   0x11                  IOERR_NO_RESOURCES
                   0x12                  IOERR_RESERVED
                   0x13                  IOERR_ILLEGAL_LENGTH
                   0x14                  IOERR_UNSUPPORTED_FEATURE
                   0x15                  IOERR_ABORT_IN_PROGRESS
                   0x16                  IOERR_ABORT_REQUESTED
                   0x17                  IOERR_RECEIVE_BUFFER_TIMEOUT
                   0x18                  IOERR_LOOP_OPEN_FAILURE
                   0x19                  IOERR_RING_RESET
                   0x1A                  IOERR_LINK_DOWN
                   0x1B                  IOERR_CORRUPTED_DATA



Host Bus Adapter for Windows and Linux Installation Guide                                   55
Troubleshooting



                  Table 7: Parameter Error Values Valid only when CmdStat=0x3 (Continued)
                    0x12 Offset                       Explanation (Continued)
                   0x1C              IOERR_CORRUPTED_RPI
                   0x1D              IOERR_OUT_OF_ORDER
                   0x1E              IOERR_OUT_OF_ORDER_ACK
                   0x1F              IOERR_DUPLICATE_FRAME
                   0x20              IOERR_INVALID_ACK
                   0x21              IOERR_BAD_40BIT_ADDRESS
                   0x1A              IOERR_RESERVED
                   0x1B              IOERR_RESERVED
                   0x1C              IOERR_RESERVED
                   0x1D              IOERR_ABORT_MULTI_REQUESTED
                   0x1E              IOERR_RESERVED
                   0x1F              IOERR_RESERVED
                   0x20              IOERR_LINK_BUFFER_SHORTAGE
                   0x21              IOERR_RCV_XRIBUF_WAITING
                   0x22              IOERR_RESERVED
                   0x23              IOERR_RESERVED
                   0x24              IOERR_RESERVED
                   0x25              IOERR_ABORT_MULTI_REQUESTED
                   0x26              IOERR_RESERVED
                   0x27              IOERR_RESERVED
                   0x28              IOERR_LINK_BUFFER_SHORTAGE
                   0x29              IOERR_RCV_XRIBUF_WAITING




56                                              Host Bus Adapter for Windows and Linux Installation Guide
Troubleshooting



SCSI Address Mapping
                  The driver emulates six SCSI buses per HBA to map all 126 possible AL_PA to
                  Target IDs.
                  The first bus is a dummy bus used to delay the initial inquiry scan until after
                  discovery completes. The 31 target IDs per bus are then mapped to either
                  ascending or descending SEL_IDs (based on the ScanDown registry parameter).


                  Note: The driver uses the first bus if the parameter MapBus0=1 is used.



Fabric Device Mapping
                  In a fabric (switched) environment, devices are initially created in the order that
                  they are returned from the Simple Name Server (SNS). Once created (at boot), the
                  devices continue to be tracked based on:
                       –WWPN:HardAddress=0;MapNodeName=0
                       –NodeName:HardAddress=0;MapNodeName=1
                       –D_ID:HardAddress=1; (MapNodeName=don’t care)


Private Loop Device Mapping for Windows Platforms
                  In a private loop environment (FC-AL, no switch), devices are initially created
                  based on a fixed address ordering. Once created (at boot), the devices continue to
                  be tracked based on:
                       –WWPN:HardAddress=0;MapNodeName=0
                       –NodeName:HardAddress=0;MapNodeName=1
                       –D_ID:HardAddress=1; (MapNodeName=don’t care)
                  This section identifies the initial fixed mapping between the Windows NT
                  bus/target/lun and a Fibre Channel native address (AL_PA/SEL_ID). There are
                  two potential mappings based on a registry parameter [ScanDown=0 (driver
                  default); use *, ScanDown=1;].




Host Bus Adapter for Windows and Linux Installation Guide                                               57
Troubleshooting



                  The index into Table 8 can be derived by:
                       #define TARGETS_PER_BUS 32
                       i = (Srb->PathId > 0) ? Srb->PathId-1 : 0; //Bus 0 = dummy bus
                       nodeInx =
                       ((I * (TARGETS_PER_BUS-1)) + Srb->TargetId;w
                  Table 8: Current Private Loop Device Mapping
                                   Target                                              **AL_P
                       Bus #         #          Lun#        *AL_PA        SEL_ID         A            SEL_ID
                         0          0-31         0-7         None         None          None          None
                   IMPORTANT: 0               0-7          0x01          0x7D         0xEF           0x00
                   *
                                  1           0-7          0x02          0x7C         0xE8           0x01
                                  2           0-7          0x04          0x7B         0xE4           0x02
                                  3           0-7          0x08          0x7A         0xE2           0x03
                                  4           0-7          0x0F          0x79         0xE1           0x04
                                  5           0-7          0x10          0x78         0xE0           0x05
                                  6           0-7          0x17          0x77         0xDC           0x06
                                  7           0-7          0x18          0x76         0xDA           0x07
                                  8           0-7          0x1B          0x75         0xD9           0x08
                                  9           0-7          0x1D          0x74         0xD6           0x09
                                  10          0-7          0x1E          0x73         0xD5           0x0A
                                  11          0-7          0x1F          0x72         0xD4           0x0B
                                  12          0-7          0x23          0x71         0xD3           0x0C
                                  13          0-7          0x25          0x70         0xD2           0x0D
                                  14          0-7          0x26          0x6F         0xD1           0x0E
                                  15          0-7          0x27          0x6E         0xCE           0x0F
                                  16          0-7          0x29          0x6D         0xCD           0x10
                                  17          0-7          0x2A          0x6C         0xCC           0x11
                                  18          0-7          0x2B          0x6B         0xCB           0x12
                                  19          0-7          0x2C          0x6A         0xCA           0x13
                                  20          0-7          0x2D          0x69         0xC9           0x14
                        *Use this translation if registry ScanDown = 0 (default).
                        **Use this translation if registry ScanDown = 1.
                        ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1.


58                                                   Host Bus Adapter for Windows and Linux Installation Guide
Troubleshooting



                  Table 8: Current Private Loop Device Mapping (Continued)
                                    Target                                              **AL_P
                      Bus #           #          Lun#        *AL_PA        SEL_ID         A            SEL_ID
                        0            0-31         0-7         None         None          None          None
                                   21          0-7          0x2E          0x68         0xC7           0x15
                                   22          0-7          0x31          0x67         0xC6           0x16
                                   23          0-7          0x32          0x66         0xC5           0x17
                                   24          0-7          0x33          0x65         0xC3           0x18
                                   25          0-7          0x34          0x64         0xBC           0x19
                                   26          0-7          0x35          0x63         0xBA           0x1A
                                   27          0-7          0x36          0x62         0xB9           0x1B
                                   28          0-7          0x37          0x61         0xB6           0x1C
                                   29          0-7          0x3A          0x60         0xB5           0x1D
                                   30          0-7          0x3C          0x5F         0xB4           0x1E
                                   31          0-7          None          None         None           None
                   IMPORTANT: 0                0-7          0x43          0x5E         0xB3           0x1F
                   ***
                                   1           0-7          0x45          0x5D         0xB2           0x20
                                   2           0-7          0x46          0x5C         0xB1           0x21
                                   3           0-7          0x47          0x5B         0xAE           0x22
                                   4           0-7          0x49          0x5A         0xAD           0x23
                                   5           0-7          0x4A          0x59         0xAC           0x24
                                   6           0-7          0x4B          0x58         0xAB           0x25
                                   7           0-7          0x4C          0x57         0xAA           0x26
                                   8           0-7          0x4D          0x56         0xA9           0x27
                                   9           0-7          0x4E          0x55         0xA7           0x28
                                   10          0-7          0x51          0x54         0xA6           0x29
                                   11          0-7          0x52          0x53         0xA5           0x2A
                                   12          0-7          0x53          0x52         0xA3           0x2B
                                   13          0-7          0x54          0x51         0x9F           0x2C
                         *Use this translation if registry ScanDown = 0 (default).
                         **Use this translation if registry ScanDown = 1.
                         ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1.



Host Bus Adapter for Windows and Linux Installation Guide                                                       59
Troubleshooting



                  Table 8: Current Private Loop Device Mapping (Continued)
                                    Target                                              **AL_P
                     Bus #            #          Lun#        *AL_PA        SEL_ID         A            SEL_ID
                       0             0-31         0-7         None         None          None          None
                                   14          0-7          0x55          0x50         0x9E           0x2D
                                   15          0-7          0x56          0x4F         0x9D           0x2E
                                   16          0-7          0x59          0x4E         0x9B           0x2F
                                   17          0-7          0x5A          0x4D         0x98           0x30
                                   18          0-7          0x5C          0x4C         0x97           0x31
                                   19          0-7          0x63          0x4B         0x90           0x32
                                   20          0-7          0x65          0x4A         0x8F           0x33
                                   21          0-7          0x66          0x49         0x88           0x34
                                   22          0-7          0x67          0x48         0x84           0x35
                                   23          0-7          0x69          0x47         0x82           0x36
                                   24          0-7          0x6A          0x46         0x81           0x37
                                   25          0-7          0x6B          0x45         0x80           0x38
                                   26          0-7          0x6C          0x44         0x7C           0x39
                                   27          0-7          0x6D          0x43         0x7A           0x3A
                                   28          0-7          0x6E          0x42         0x79           0x3B
                                   29          0-7          0x71          0x41         0x76           0x3C
                                   30          0-7          0x72          0x40         0x75           0x3D
                                   31          0-7          None          None         None           None
                   IMPORTANT: 0                0-7          0x73          0x3F         0x74           0x3E
                   ***
                                   1           0-7          0x74          0x3E         0x73           0x3F
                                   2           0-7          0x75          0x3D         0x72           0x40
                                   3           0-7          0x76          0x3C         0x71           0x41
                                   4           0-7          0x79          0x3B         0x6E           0x42
                                   5           0-7          0x7A          0x3A         0x6D           0x43
                                   6           0-7          0x7C          0x39         0x6C           0x44
                         *Use this translation if registry ScanDown = 0 (default).
                         **Use this translation if registry ScanDown = 1.
                         ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1.



60                                                    Host Bus Adapter for Windows and Linux Installation Guide
Troubleshooting



                  Table 8: Current Private Loop Device Mapping (Continued)
                                   Target                                              **AL_P
                      Bus #          #          Lun#        *AL_PA        SEL_ID         A            SEL_ID
                        0           0-31         0-7         None         None          None          None
                                  7           0-7           0x80         0x38         0x6B           0x45
                                  8           0-7           0x81         0x37         0x6A           0x46
                                  9           0-7           0x82         0x36         0x69           0x47
                                  10          0-7           0x84         0x35         0x67           0x48
                                  11          0-7           0x88         0x34         0x66           0x49
                                  12          0-7           0x8F         0x33         0x65           0x4A
                                  13          0-7           0x90         0x32         0x63           0x4B
                                  14          0-7           0x97         0x31         0x5C           0x4C
                                  15          0-7           0x98         0x30         0x5A           0x4D
                                  16          0-7           0x9B         0x2F         0x59           0x4E
                                  17          0-7           0x9D         0x2E         0x56           0x4F
                                  18          0-7           0x9E         0x2D         0x55           0x50
                                  19          0-7           0x9F         0x2C         0x54           0x51
                                  20          0-7           0xA3         0x2B         0x53           0x52
                                  21          0-7           0xA5         0x2A         0x52           0x53
                                  22          0-7           0xA6         0x29         0x51           0x54
                                  23          0-7           0xA7         0x28         0x4E           0x55
                                  24          0-7           0xA9         0x27         0x4D           0x56
                                  25          0-7           0xAA         0x26         0x4C           0x57
                                  26          0-7           0xAB         0x25         0x4B           0x58
                                  27          0-7           0xAC         0x24         0x4A           0x59
                                  28          0-7           0xAD         0x23         0x49           0x5A
                                  29          0-7           0xAE         0x22         0x47           0x5B
                                  30          0-7           0xB1         0x21         0x46           0x5C
                                  31          0-7           None         None         None           None
                        *Use this translation if registry ScanDown = 0 (default).
                        **Use this translation if registry ScanDown = 1.
                        ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1.



Host Bus Adapter for Windows and Linux Installation Guide                                                      61
Troubleshooting



                  Table 8: Current Private Loop Device Mapping (Continued)
                                    Target                                              **AL_P
                     Bus #            #          Lun#        *AL_PA        SEL_ID         A            SEL_ID
                       0             0-31         0-7         None         None          None          None
                   IMPORTANT: 0                0-7          0xB2          0x20         0x45           0x5D
                   ***
                                   1           0-7          0xB3          0x1F         0x43           0x5E
                                   2           0-7          0xB4          0x1E         0x3C           0x5F
                                   3           0-7          0xB5          0x1D         0x3A           0x60
                                   4           0-7          0xB6          0x1C         0x39           0x61
                                   5           0-7          0xB9          0x1B         0x36           0x62
                                   6           0-7          0xBA          0x1A         0x35           0x63
                                   7           0-7          0xBC          0x19         0x34           0x64
                                   8           0-7          0xC3          0x18         0x33           0x65
                                   9           0-7          0xC5          0x17         0x32           0x66
                                   10          0-7          0xC6          0x16         0x31           0x67
                                   11          0-7          0xC7          0x15         0x2E           0x68
                                   12          0-7          0xC9          0x14         0x2D           0x69
                                   13          0-7          0xCA          0x13         0x2C           0x6A
                                   14          0-7          0xCB          0x12         0x2B           0x6B
                                   15          0-7          0xCC          0x11         0x2A           0x6C
                                   16          0-7          0xCD          0x10         0x29           0x6D
                                   17          0-7          0xCE          0x0F         0x27           0x6E
                                   18          0-7          0xD1          0x0E         0x26           0x6F
                                   19          0-7          0xD2          0x0D         0x25           0x70
                                   20          0-7          0xD3          0x0C         0x23           0x71
                                   21          0-7          0xD4          0x0B         0x1F           0x72
                                   22          0-7          0xD5          0x0A         0x1E           0x73
                                   23          0-7          0xD6          0x09         0x1D           0x74
                                   24          0-7          0xD9          0x08         0x1B           0x75
                         *Use this translation if registry ScanDown = 0 (default).
                         **Use this translation if registry ScanDown = 1.
                         ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1.



62                                                    Host Bus Adapter for Windows and Linux Installation Guide
Troubleshooting



                  Table 8: Current Private Loop Device Mapping (Continued)
                                     Target                                              **AL_P
                      Bus #            #          Lun#        *AL_PA        SEL_ID         A            SEL_ID
                        0             0-31         0-7         None         None          None          None
                                    25          0-7          0xDA          0x07         0x18           0x76
                                    26          0-7          0xDC          0x06         0x17           0x77
                                    27          0-7          0xE0          0x05         0x10           0x78
                                    28          0-7          0xE1          0x04         0x0F           0x79
                                    29          0-7          0xE2          0x03         0x08           0x7A
                                    30          0-7          0xE4          0x02         0x04           0x7B
                                    31          0-7          None          None         None           None
                   IMPORTANT: 0                 0-7          0xE8          0x01         0x02           0x7C
                    ***
                                    1           0-7          0xEF          0x00         0x01           0x7D
                                    2           0-7          None          None         None           None
                                    3           0-7          None          None         None           None
                                    4           0-7          None          None         None           None
                                    5           0-7          None          None         None           None
                                    6           0-7          None          None         None           None
                                    7           0-7          None          None         None           None
                                    8           0-7          None          None         None           None
                                    9           0-7          None          None         None           None
                                    10          0-7          None          None         None           None
                                    11          0-7          None          None         None           None
                                    12          0-7          None          None         None           None
                                    13          0-7          None          None         None           None
                                    14          0-7          None          None         None           None
                                    15          0-7          None          None         None           None
                                    16          0-7          None          None         None           None
                                    17          0-7          None          None         None           None
                          *Use this translation if registry ScanDown = 0 (default).
                          **Use this translation if registry ScanDown = 1.
                          ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1.



Host Bus Adapter for Windows and Linux Installation Guide                                                        63
Troubleshooting



                  Table 8: Current Private Loop Device Mapping (Continued)
                                  Target                                              **AL_P
                     Bus #          #          Lun#        *AL_PA        SEL_ID         A            SEL_ID
                       0           0-31         0-7         None         None          None          None
                                 18          0-7          None          None         None           None
                                 19          0-7          None          None         None           None
                                 20          0-7          None          None         None           None
                                 21          0-7          None          None         None           None
                                 22          0-7          None          None         None           None
                                 23          0-7          None          None         None           None
                                 24          0-7          None          None         None           None
                                 25          0-7          None          None         None           None
                                 26          0-7          None          None         None           None
                                 27          0-7          None          None         None           None
                                 28          0-7          None          None         None           None
                                 29          0-7          None          None         None           None
                                 30          0-7          None          None         None           None
                                 31          0-7          None          None         None           None
                       *Use this translation if registry ScanDown = 0 (default).
                       **Use this translation if registry ScanDown = 1.
                       ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1.




64                                                  Host Bus Adapter for Windows and Linux Installation Guide
Diagnostic and Configuration
Utilities
                                                                                      5
                                                   5
                  This chapter contains instructions for installing and using the following Windows
                  NT and Windows 2000 utilities:
                  ■    DOS Diagnostic utility, x86DNLD, a DOS-based diagnostic and firmware
                       download utility. This utility is used exclusively in standalone environments.
                  ■    LightPulse Utility/NT, LP6DUTIL is a Windows-based graphical user
                       interface for updating firmware and Boot code. This utility is used in Software
                       Solution kits.


                  Note: The diagnostic and firmware download utility is used to upgrade firmware on
                  both Host Bus Adapter (HBA) environments.




Host Bus Adapter for Windows and Linux Installation Guide                                             65
Diagnostic and Configuration Utilities



The DOS Diagnostic Utility
                   The supplied software kit contains the DOS Diagnostic and firmware download
                   utility.
                   Functionally, the utility program performs:
                   ■    Discovery and preliminary testing of the HBA in the system.
                   ■    Functional testing and operational checks on the HBA.
                   ■    The use of input and output files for automating the use of the diagnostic
                        utility program.
                   ■    Updating HBA firmware.


                        Note: The diagnostic utility does not operate in the DOS shell under Windows.



Installing the DOS Diagnostic Utility
                   You must load the software and start the diagnostic utility from the DOS
                   command line. You can run the program directly from the supplied software kit or
                   you can load onto your hard drive and run it from there.


                   Note: The diagnostic utility does not operate in the DOS shell under Windows.


                   To install the utility onto the hard drive:
                   1. Insert the supplied diskette into your system’s diskette drive.
                   2. Make a directory and copy the files onto your hard drive, as follows:
                        C:MD_DIRNAME
                        C:COPY A:i386*.*C:DIR_NAME
                        C:CD DIR_NAME
                   DIR_NAME is the directory where the you install the diagnostic software.

Starting the DOS Diagnostic Utility
                   To start the program without any options, enter:
                        X86DNLD.EXE




66                                                  Host Bus Adapter for Windows and Linux Installation Guide
Diagnostic and Configuration Utilities



                  The options for X86DNLD are listed in Table 9. The syntax for using options is:
                       A:X86DNLD.EXE {I = infilename} {o = outfilename}
                  The following example shows a sample command:
                       C: X86DNLD.EXE o = PCIHA001
                  PCIHA001    is the output filename.
                  Table 9: DOS Diagnostic Utility Command Options
                       Option                                     Description
                   Infilename        Script input file that is read and executed by the program.
                   Outfilename       Creates a file of keystrokes that is stored for later use (for example,
                                     as an input file).


                  Note: All message lines except user input begin with a number symbol (#) to indicate
                  a comment line. Data entered by the user appears on a line by itself, not preceded
                  by a #.



Using the DOS Diagnostic Utility for Preliminary Testing
                  The diagnostic program performs preliminary analysis of the HBA before
                  displaying the main menu. If no HBA is found, the program exits. Error messages
                  are displayed on failure conditions.
                  During startup, the diagnostic and firmware download utility program:
                  1. Looks for installed PCI HBAs.
                  2. Executes preliminary testing on all installed HBAs. Tests include:
                       a. SLIM memory test
                       b. BIU register test
                       c. BIU configuration registers test
                  3. Reports pass or fail status messages.
                  4. Resets the HBAs.
                  5. Checks Power-On Self Test (POST) status of HBAs.
                  6. Reports revision levels of diagnostic and functional firmware.
                  7. Displays the resources of each HBA.



Host Bus Adapter for Windows and Linux Installation Guide                                                      67
Diagnostic and Configuration Utilities



                   The following is a sample output of the DOS Diagnostic Utility Start-Up
                   Procedure.
                          *************************************************************
                          **

                          WARNING: This utility may not work with the Expanded Memory
                          Manager

                          (EMM386). Please read LP6DUTIL documentation for further
                          details.

                          *************************************************************
                          **

                          LP6000 Host Adapters found in the system: 1



                          PRELIMINARY TESTING of Host Adapter 1

                          Host Adapter 1: PASS 0xA: SLIM Memory Tests

                          Host Adapter 1: PASS 0xA: BIU Registers Tests

                          Host Adapter 1: PASS 0xA: BIU Configuration Registers Tests

                          Adapter 1 PASSED PRELIMINARY TESTS

                          Resetting Host Adapter 1

                          Host Adapter 1: POST Done.

                          Host Adapter 1 is READY. Functional Firmware Loaded.

                          Diagnostic Firmware Version x.x

                          Functional Firmware Version x.x

                          Hit RETURN or ENTER key to continue



                          HOST ADAPTER 1 Resources Info

                          pci_bus_num = 0 pci_dev_num = 0xA0

                          slim_base_adr = 0x000D0000 reg_mem_base_adr = 0x000D1000

                          reg_io_base_adr = 0x0000FC00 IRQ = 0xB




68                                               Host Bus Adapter for Windows and Linux Installation Guide
Diagnostic and Configuration Utilities



                        NOTE: Enter 0 in 'Option:' prompt to display previous menu

                        NOTE: All values entered are hexadecimal

                        LP6DUTIL Main Menu Revision x.x

                        1 - Test Host Adapters

                        2 - Modify Test Options

                        3 - Restart Host Adapters

                        4 - Input/Output

                        5 - Maintenance

                        6 - Show Host Adapters Info

                        7 - Quit

                        Option:


DOS Diagnostic Utility Main Menu
                  After the diagnostic and firmware download utility goes through its start-up
                  procedure, the Main menu displays and handles user requests. If the program
                  detects two or more HBAs in the system, you are prompted to choose which
                  HBAs is to be tested.
                  Table 9 lists the function of each option on the Main menu.
                  Table 10: DOS Diagnosis Utility Main Menu Selections
                        Menu Selection                                  Description
                   1 – Test Host Adapters          Runs host-based internal and external loopback tests.
                   2 – Modify Test Options         Enables you to disable or enable up to seven different
                                                   tests, depending upon the cards installed (BIU-1 or
                                                   BIU-2). Specify number of retries and actions to take if
                                                   error occurs.
                   3 – Restart Host Adapters       Resets the HBA.
                   4 – Input/Output                Opens or closes input and output files.




Host Bus Adapter for Windows and Linux Installation Guide                                                    69
Diagnostic and Configuration Utilities



                   Table 10: DOS Diagnosis Utility Main Menu Selections
                     5 – Maintenance             Updates firmware or non-volatile parameters in FLASH
                                                 ROM. Displays program images stored in memory.
                     6 – Show Host Adapters      Displays configuration and status data used by HP
                     Info                        Technical Support.
                     7 – Quit                    Exits the program.




                   Note: Enter zero (0) at the Option prompt to display the previous menu. All values are
                   in reported hexadecimal.


                   The menu options and descriptions are described in the following sections.




70                                                  Host Bus Adapter for Windows and Linux Installation Guide
Diagnostic and Configuration Utilities



LightPulse Utility/NT Utility
                  The LightPulse Utility/NT utility (lputilnt and lputil64) is a Host Bus Adapter
                  (HBA) monitoring and management utility that lets you:
                  ■    View HBA parameters
                  ■    Modify driver parameters in the Windows registry
                  These parameters have been set by the Original Equipment Manufacturer (OEM)
                  setup file provided in the software kit. The Fibre Channel setup file, run as part of
                  the platform kit configuration, will also modify them. The resulting parameter
                  setting has been modified to provide the optimal setting for the supported
                  configurations.
                  The features and commands for the configuration utility for Windows Server 2003
                  (LPutil64.exe) are similar to those of the Windows NT and Windows 2000
                  configuration utility (lputilnt.exe). These differences will be pointed out in this
                  document where appropriate.
                  You can run the utility from the CD or copy and run it from your local hard drive.


                  Note: You must install and connect the SCSI Miniport driver to at least one drive before
                  LightPulse Utility/NT can operate properly. You can alternately set the registry
                  parameter Simulate Device= to 1.



View HBA Parameters
                  From the LightPulse Utility/NT Main menu screen:
                  1. Choose an HBA. On the menu bar, click on an HBA or pull down the category
                     list.
                  2. Choose an option to view HBA parameters.
                       There are nine options available, each displaying a different group of HBA
                       parameters:
                       ■   Adapter Revision Levels—View information about the chipset and
                           firmware revision levels of the selected HBA.
                       ■   Firmware Maintenance—Maintain firmware revision levels of the
                           selected HBA.
                       ■   Loop Map—View a list of the members of the selected HBA loop map.



Host Bus Adapter for Windows and Linux Installation Guide                                                  71
Diagnostic and Configuration Utilities



                        ■    PCI Registers—Maintain the values of the PCI configuration registers of
                             the selected HBA.
                        ■    Configuration Data—Maintain information about the data in each of the
                             configuration regions in the flash ROM of the selected HBA.
                        ■    Driver Parameters—Maintain information about device driver parameters
                             that are maintained in the Windows/NT registry.
                        ■    Persistent Bindings—Maintain information about persistent bindings of
                             the selected HBA.
                        ■    Link Statistics—Maintain statistics about the arbitrated loop of the
                             selected HBA.
                        ■    Status and Counters—Maintain status and counters for bytes, frames,
                             sequences, exchanges, and so on.

Maintaining HBA Firmware Revision Levels
                   1. Choose the desired HBA.
                   2. Expand the category list and choose Firmware Maintenance.
                   3. Click Download.
                   4. Locate the new upgrade file.
                   5. Click Open.


                        Note: The new software is transferred to the HBA.


                   6. Expand the category list and choose Adapter Revision Levels.
                   7. Verify that the new firmware revision is shown.

Modify Diagnostic Driver Parameters in the Windows Registry
                   This screen provides information about device driver parameters that are
                   maintained in the Windows registry and allows you to modify those values.




72                                                  Host Bus Adapter for Windows and Linux Installation Guide
Diagnostic and Configuration Utilities




                           Caution: Do not modify the registry parameters unless specifically instructed
                           to do so by support personnel. Modifying registry parameters can result in an
                           unstable SAN.


                  The data display lists all available device driver parameters, along with the
                  current, minimum, maximum, and default values. Parameters that have their value
                  specified in the system registry are denoted with either a G or an L in the left-most
                  column of the screen. The G indicates that the value is set in the global registry
                  entry, which applies to all HBAs that do not have a local registry entry. The L
                  indicates that the value is set in a registry entry specific to the selected HBA,
                  which overrides the value settings in the global entry.

Modify the Driver Parameters
                  From the LightPulse Utility/NT Main menu screen:
                  1. Choose the desired HBA.
                  2. Expand the category list and choose Driver Parameters.
                  3. Double-click a Parameter Name.
                  4. Enter the desired value in the New Value field.
                  5. Choose the Permanent or Global checkbox:
                       ■   Choose Permanent to cause the new value to be written to the system
                           registry. If Permanent is not selected, the parameter reverts to its default
                           value when the driver is reset.
                       ■   Choose Global to change the global registry entry. Otherwise, the change
                           is made to the HBA-specific registry entry.
                  Table 11 lists the current parameters that you can set.
                  Table 11: Driver Parameters
                        Parameter                                   Description
                   AbortStatus = 0xn        Values from 0x00 – 0xFF. Controls NT SRB error status for
                                            general Abort conditions.
                                            Default = SRB_STATUS_BUS_RESET (0x0E) which will not
                                            cause the current NT class driver to throttle down I/O
                                            performance after four of these errors have been received (on
                                            a per-LUN basis)
                   ALTOV = n                Values are in milliseconds from 1 to 15. Default = 15.


Host Bus Adapter for Windows and Linux Installation Guide                                                   73
Diagnostic and Configuration Utilities



                   Table 11: Driver Parameters (Continued)
                     ARBTOV = n          Values are milliseconds form 500 to 10000. Default = 1000.
                                         Represents FC_AL arbitration time-out prior to LIP.
                     Class = n           Values from 0-2. Default = 2. Controls which Fibre Channel
                                         Class will be used: 0 = Class 1, 1 = Class 2, 2 = Class 3.
                     EDTOV = n           Values are in milliseconds form 500 to 10000. Default =
                                         1000. Represents error detect time-out value prior to LIP.
                     EnableDPC = n       Values 0 or 1. Default = 0. 0 = process I/O completion at
                                         interrupt level, 1 = process at DPC level.
                     FrameSizeMSB = n    Values from 1-8. Default = 8. Controls the upper byte of the
                                         receive FrameSize if issued in PLOGI. This lets the FrameSize
                                         to be constrained on 256 byte increments from 256 (1) –
                                         2048 (8).
                     HardALPA = 0xn      Values from 0x01 – 0xEF. Default = 0x01 lets the HBA use a
                                         hard assigned loop address. NOTE: Only valid ALPAs can
                                         be used (see Table 6-2).
                     LinkTimeOut = n     Values are in seconds from 1 – 500. Default = 60. Controls
                                         the time-out at which link no longer busy requests but issues
                                         SELECTION_TIMEOUT error status.
                     LogErrors = n       Values 0 or 1. Default = 0. 0 = don’t log general HBA/drive
                                         errors. 1 = use Event Log to general errors.
                     NodeTimeOut = n     Values are in seconds from 1–255.
                                         Default = 10. Controls the time-out at which a formerly
                                         logged-in node will issue SELECTION_TIMEOUT error status
                                         to an I/O request.
                     QueueDepth = n      Values from 1–64 (decimal). Default = 64. Requests per
                                         LUN/Target (see Queue Target parameter).
                     QueueTarget = n     Vaules 0 or 1 (decimal). Default = 0. 0 = QueueDepth
                                         applies on a per LUN basis: 1 = QueueDepth applies on a
                                         Target basis.
                     RATOV = n           Values are in seconds from 2 to 120. Default = 2. This value
                                         is the ELS request time-out.
                     ReadCheck = n       Values 0 or 1. Default = 1. 0 = do not enable byte counting
                                         for read operations. 1 = enable byte counting. If bytes
                                         counted are less than requested transfer count, issue
                                         underrun.




74                                               Host Bus Adapter for Windows and Linux Installation Guide
Diagnostic and Configuration Utilities



                  Table 11: Driver Parameters (Continued)
                   ResetFF = n              Values 0 or 1. Default = 1. 0 = ResetBus translates to LIP (F7).
                                            1 = ResetBus translates to LIP (FF). Used for WolfPack to force
                                            reservations to be freed when ResetBus issued. Only
                                            meaningful for FC_AL topology and Seagate native FC hard
                                            drives.
                   ResetTPRLO = n           Values 0 or 1. Default = 1. 0 = ResetBus translates to LIP (). 1
                                            = ResetBus translates to ThirdPartyProcessLogout + LIP ().
                                            Used for WolfPack to force reservations to be freed when
                                            ResetBus is issued.
                   RetryInterval = n        Values are in seconds from 2-255. Default = 45. Used for
                                            time-out interval if RetryloTimeOut = 1. Must be shorter than
                                            Class driver TimeOutInterval.
                   RetryloTimeOut = n       Vaules 0 or 1. Default = 1. 1 = lets an HBA to time-out I/O
                                            prior to port driver’s time-out which causes a LIP/Link Reset.
                   RTTOV = n                Values are in milliseconds from 100 to 511. Default = 256.
                                            Represents time-out between phases of Off-line to On-line
                                            protocol.
                   ScanDown = n             Values 0 or 1. Default = 0. 0 = Lowest AL_PA = Lowest
                                            physical disk (ascending AL_PA order). 1 = Highest AL_PA =
                                            Lowest Physical Disk (ascending SEL_ID order).
                   SilFlags = n             Values from 0-2. Default = 0. Controls which driver interface
                                            to use. 0 = automode; attempt SLI-2 first. If that fails, uses
                                            SLI-1. 1 = always use SLI-1. 2 = always use SLI-2.
                   SimulateDevice = n       Values 0 or 1. Default = 0. 0 = do not create a “dummy” disk
                                            device. 1 = create a dummy disk to force the driver to load
                                            even if no disk devices are present at boot time.
                   SnsALL = n               Values 0 or 1. Default = 1. Controls which N_Ports are
                                            queried from the NameServer. 0 = SCSI FCP only. 1 = All
                                            N_Ports.
                   Topology = n             Values 0 or 1. Default = 0. 0 = FC_AL (loop), 1 = PT-PT
                                            Fabric. When set to 1, FLOGI, SCR/RSCN and NameServer
                                            queries are employed.
                   TrafficCop = n           Values 0 or 1. Default = 0. 1 = enable FC-AL loop master to
                                            run unfair and break potential arbitration problems by
                                            sending frames to itself. 0 = run fair all the time.




Host Bus Adapter for Windows and Linux Installation Guide                                                    75
Diagnostic and Configuration Utilities



                   Table 12 lists the Arbitrated Loop Physical Addresses you can set.
                   Table 12: AL-PA Addresses
                     0x01        0x02    0x04     0x08      0x0F      0x10      0x17       0x18      0x1B
                     0x1D        0x1E    0x1F     0x23      0x25      0x26      0x27       0x29      0x2A
                     0x2B        0x2C    0x2D     0x2E      0x31      0x32      0x33       0x34      0x35
                     0x36        0x39    0x3A     0x3C      0x43      0x45      0x46       0x47      0x49
                     0x4A        0x4b    0x4C     0x4D      0x4D      0x51      0x52       0x53      0x54
                     0x55        0x56    0x59     0x5A      0x5C      0x63      0x65       0x66      0x67
                     0x69        0x6A    0x6B     0x6C      0x6D      0x6E      0x71       0x72      0x73
                     0x74        0x75    0x75     0x79      0x7A      0x7C      0x80       0x81      0x82
                     0x84        0x88    0x8F     0x90      0x97      0x98      0x9B       0x9D      0x9E
                     0x9F        0xA3    0xA5     0xA6      0xA7      0xA9      0xAA       0xAB      0xAC
                     0xAD        0xAE    0xB1     0xB2      0xB3      0xB4      0xB5       0xB6      0xB9
                     0xBA        0xBC    0xC3     0xC5      0xC6      0xC7      0xC9       0xCA      0xCB
                     0xCC        0xCD    0xCE     0xD1      0xD2      0xD3      0xD4       0xD5      0xD5
                     0xD9        0xDA    0xDC     0xE0      0xE1      0xE2      0xE4       0xE8      0xEF


Test Host Bus Adapters (For lputilnt Only)
                   Choose this option to run host-based internal and external loopback tests on the
                   HBAs.
                   From the LightPulse Utility/NT Main menu screen:
                   1. Choose Test Host Bus Adapters.
                   2. Enable or disable the external loopback tests:
                        a. Enable the external loopback tests by selecting 1=Y. The default is
                           disabled, 0=No. Internal BIU PCI loopback and other loopback tests are
                           run automatically.
                        b. Choose 0=No if you do not have an external loopback connector.


                             Note: Testing the HBA while it is connected to an arbitrated loop is not
                             recommended.




76                                                   Host Bus Adapter for Windows and Linux Installation Guide
Diagnostic and Configuration Utilities



Modify Test Options (For lputilnt Only)
                  Use this option to specify the number of passes on one or more of these tests: PCI
                  loopback, internal loopback, external Loopback, or all three.
                  From the LightPulse Utility/NT Main menu screen:
                  1. Choose Test.
                  2. Choose the following data for the PCI loopback, Internal loopback, External
                     Loopback tests:
                       a. The number of passes. The default is 0x50. 0=infinity
                       b. The action to take upon encountering errors. Choose one of the following:
                           — 0 = stop (default)
                           — 1 = repeat
                           — 2 = ignore

Reset Host Bus Adapters
                  Choose this option to reset the HBA. When a reset HBA occurs, the HBA
                  performs POST testing and reloads functional firmware.

Input/Output
                  Choose this option to open or close input and output files. The contents of the
                  Input file are interpreted and executed by the program. The output file contains a
                  log of all messages. Note that nesting of input files is not supported.

Show Host Bus Adapter Info (For lputilnt Only)
                  Choose this option to display HBA data in these areas:
                  ■    BIU PCI Configuration Parameters
                  ■    Host Bus Adapter Info and Status
                  ■    Adapter Revisions
                  ■    Display Configuration Data
                  ■    Service Parameters
                  ■    Status/Counters Info
                  ■    Link Status


Host Bus Adapter for Windows and Linux Installation Guide                                               77
Diagnostic and Configuration Utilities



                   ■    Link Attention

Quit the LightPulse Utility/NT Utility
                   Choose this option to exit the program. A warning message indicates if any errors
                   were encountered during the session.




78                                                Host Bus Adapter for Windows and Linux Installation Guide
Regulatory Compliance
Notices
                                                                                    A
                                                  A
FCC Compliance Information Statement
                  This device complies with Part 15 of the FCC Rules. Operation is subject to the
                  following two conditions: (1) This device may not cause harmful interference, and
                  (2) this device must accept any interference received, including interference that
                  may cause undesired operation.
                  This equipment has been tested and found to comply with the limits for a Class A
                  digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
                  provide reasonable protection against harmful interference when the equipment is
                  operated in a commercial environment. This equipment generates, uses, and can
                  radiate radio frequency energy and, if not installed and used in accordance with
                  the instruction manual, may cause harmful interference to radio communications.
                  Operation of this equipment in a residential area is likely to cause harmful
                  interference in which case the user will be required to correct the interference at
                  his own expense. Shielded cables must be used between this equipment and
                  attached peripheral devices. The reader is cautioned that changes or modifications
                  made to the equipment not expressly approved could void the user's authority to
                  operate this equipment.
                  Hewlett-Packard Company
                  3000 Hanover Street
                  Palo Alto, CA 94304-1185
                  Or call 1-650-857-1501. (For continuous quality improvement, calls may be
                  recorded or monitored.)
                  To identify the device, refer to the part, series or model number found on the
                  product.

Host Bus Adapter for Windows and Linux Installation Guide                                          79
Regulatory Compliance Notices



                 The above statement applies to products marketed in the USA.

Japanese Notice




Canadian Notice
                 This Class A digital apparatus meets all requirements of the Canadian
                 Interference-Causing Equipment Regulations.

Avis Canadien
                 Cet appareil numérique de la classe A respecte toutes les exigences du Règlement
                 sur le matériel brouilleur du Canada.




80                                             Host Bus Adapter for Windows and Linux Installation Guide
Regulatory Compliance Notices



Federal Communications Commission Notice
                  This equipment has been tested and found to comply with the limits for a Class B
                  digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
                  provide reasonable protection against harmful interference in a residential
                  installation. Any modifications to this device - unless expressly approved by the
                  manufacturer - can void the user’s authority to operate this equipment under part
                  15 of the FCC rules. Operation is subject to the following two conditions: (1) This
                  device may not cause harmful interference and (2) This device must accept any
                  interference that may cause undesirable operation.
                  This equipment generates, uses, and can radiate radio frequency energy and, if not
                  installed and used in accordance with the instructions, may cause harmful
                  interference to radio communications. However, there is no guarantee that
                  interference will not occur in a particular installation.
                  If this equipment does cause harmful interference to radio or television reception,
                  which can be determined by turning the equipment off and on, the user is
                  encouraged to try to correct the interference by one or more of the following
                  measures:
                  ■    Reorient or relocate the receiving antenna.
                  ■    Increase the separation between the equipment and receiver.
                  ■    Connect the equipment into an outlet on a circuit different from that to which
                       the receiver is connected.
                  ■    Consult the dealer or an experienced radio/TV technician for help.


                  Note: Additional information on the need to interconnect the device with shielded
                  (data) cables or the need for special devices, such as ferrite beads on cables, is
                  required if such means of interference suppression was used in the qualification test for
                  the device. This information will vary from device to device and needs to be obtained
                  from the EMC group or product manager.




Host Bus Adapter for Windows and Linux Installation Guide                                                81
Regulatory Compliance Notices



Japanese Notice




Canadian Notice
                 This Class B digital apparatus meets all requirements of the Canadian
                 Interference-Causing Equipment Regulations.

Avis Canadien
                 Cet appareil numérique de la classe B respecte toutes les exigences du Règlement
                 sur le matériel brouilleur du Canada.




82                                             Host Bus Adapter for Windows and Linux Installation Guide
glossary



                                              Glossary
                  This glossary defines terms used in this guide or related to this product and is not
                  a comprehensive glossary of computer terms.
                                                   Glossary
 AL-PA
 Arbitrated Loop Physical Address. The address of a Fibre Channel node in an arbitrated loop.
 Arbitration
 The process of selecting one respondent from a collection of several candidates that request
 service at the same time.
 b/s (or bps)
 Bits per second. The number of energy pulses passing a given point in a transmission medium in
 one second; raw transmission speed before encoding.
 Bandwidth
 A measure of the information-carrying capacity of an optical fiber, normalized to a unit of
 MHz/km. This term is used to specify capacity of multi-mode fibers only. (For single-mode
 fibers, use dispersion). The difference between the highest and lowest frequencies in a specific
 range of frequencies.
 Baud
 A unit of signaling speed equal to the number of signal intervals per second, which might or
 might not be equal to the data rate in bits per second. The encoded bit rate per second.
 BIOS
 Basic Input/Output system. Software coded into the computer chips to accomplish various
 tasks.
 Boot BIOS
 Software coded into the chips on the HBA. A special program used to boot and control the
 computer.
 Broadband
 In data transmission, it denotes transmission facilities capable of handling frequencies greater
 than those required for high-grade voice communications. The higher frequency allows the
 carrying of several simultaneous channels.


Host Bus Adapter for Windows and Linux Installation Guide                                           83
Glossary



 Cladding
 The dielectric material surrounding the core of an electrical fiber or material surrounding the
 core of a fiber optic cable. It usually refers to diameter, often 125 m, measured in microns.
 Connector
 A mechanical device used to align and join two fibers together to provide a means for attaching
 and decoupling it to a transmitter, receiver, or another fiber.
 Core
 The central region of an optical fiber through which light is transmitted.
 Custom Device Module (CDM)
 A CDM is the driver component in the NetWare Peripheral Architecture used to drive specific
 storage devices attached to the HBA. See also NetWare Peripheral Architecture.
 Data Rate
 The maximum number of bits of information that can be transmitted per second in a data
 transmission link. It is typically expressed as Megabits per second (Mbps).
 Device Driver
 A software program that enables a personal computer to communicate with hard drives,
 CD-ROM drives, printers, and other peripherals. Device drivers are stored on a hard drive and
 are loaded into memory at boot up.
 Duplex Cable
 A two-fiber cable suitable for duplex transmission or transmissions in two directions.
 Duplex Transmission
 Transmission in both directions, either one direction at a time (half duplex) or both directions
 simultaneously (full duplex).
 Fabric
 A Fibre Channel interconnection method that allows multiple simultaneous and concurrent data
 transfers between multiple hosts and/or storage devices connected with a multi-port hub.
 FC-AL
 Abbreviation for Fibre Channel Arbitrated Loop, an interconnection scheme that supports from
 1 to 126 ports on a loop in a shared medium topology.
 FCP
 Fibre Channel Protocol.
 FDDI
 Fibre Distributed Data Interface. A network based on the use of optical-fiber cable to transmit
 data at 100Mbit/sec.




84                                              Host Bus Adapter for Windows and Linux Installation Guide
Glossary



 Fiber
 Thin filament of glass. An optical waveguide consisting of a core and cladding, which is
 capable of carrying information in the form of light. Fibre is also a general term used to cover
 all physical media types supported by Fibre Channel, such as optical fiber, twisted pair, and
 coaxial cable.
 Fiber Optics
 Light transmission through optical fibers for communication or signaling.
 Fibre Channel
 A high-speed, serial, bi-directional, topology independent, multi-protocol, highly scalable
 interconnection between computers, peripherals, and networks.
 Gb/s
 Gigabits per second or 1 billion bits per second. A reference to processing speed.
 GB/s
 Gigabytes per second or 1,073,741,824 bytes per second. A reference to processing speed.
 GLM
 Gigabit Link Module. A transmitter and receiver that provides high-speed serial links, enabling
 continuous throughput in each direction simultaneously.
 Host Adapter Module (HAM)
 A HAM is the driver component used to drive specific HBA hardware in the NetWare
 Peripheral Architecture (NPA).
 Interrupt Request (IRQ)
 Network boards are supplied with default settings for the IRQ, I/O port and base memory
 address. An IRQ is a signal protocol used by hardware devices, such as printers and modems, to
 let the computer know that they need some attention. When an IRQ is invoked, the CPU puts its
 other work “on hold” and services the needs of the interrupting device.
 Kilometer
 1,000 meters or 3,281 feet. The kilometer is a unit of measurement commonly used in fiber
 optics. To convert kilometers to miles, multiply the number of kilometers by .62 to achieve the
 number of miles. To convert miles to kilometers, multiply the number of miles by 1.61 to
 achieve the number in kilometers.
 Laser
 Light Amplification by Stimulated Emission of Radiation. A device that produces coherent light
 with a narrow range of wavelengths.
 Latency
 Delay in transmission; can be caused by arbitration time prior to winning control of the
 network.



Host Bus Adapter for Windows and Linux Installation Guide                                           85
Glossary



 Light
 In the laser and optical communication fields, the portion of the electromagnetic spectrum that
 can be handled by the basic optical techniques used for the visible spectrum extending from the
 near ultraviolet region of approximately 0.3 micron, through the visible region, and into the
 mid-infrared region of about 30 microns.
 Light Emitting Diode (LED)
 A device used in a transmitter to convert information from electrical to optical form. It typically
 has a large spectral width.
 Lightwaves
 Electromagnetic waves in the region of optical frequencies. The term “light” was originally
 restricted to radiation visible to the human eye, with wavelengths between 400 and 700
 nanometers (nm). However, it has become customary to refer to radiation in the spectral regions
 adjacent to visible light (in the near infrared from 700 to about 2000 nm) as “light” to
 emphasize the physical and technical characteristics.
 Link
 A fiber optic cable with connectors attached to a transmitter (source) and receiver (detector).
 Longwave
 Refers to length of the wave or frequency in the spectrum of light. 780 nm is the operating range
 of short wave lasers, while 1300 nm describes the range of long wave lasers.
 LUN
 Logical Unit Number. A three-bit identifier for a Logical Unit. The maximum number of LUNs
 per SCSI target is 8, numbered LUN0 through LUN7.
 Mb/s
 Megabits per second or 1,000 bits per second. A reference to processing speed.
 MB/s
 Megabytes per second or 1,000 bytes per second. A reference to processing speed.
 Media Manager (MM)
 A database built into NetWare that keeps track of all peripheral storage devices and media
 attached to NetWare servers, and allows applications to gain access and get information. The
 Media Manager receives application I/O requests and converts them to messages compatible
 with the NPA architecture.
 Micron (mm)
 Another term for micrometer. One millionth of a meter. 10-6 meter.
 Mode
 A term used to describe a light path through a fiber, as in multi-mode or single-mode.




86                                               Host Bus Adapter for Windows and Linux Installation Guide
Glossary



 Multi-initiators
 Two different Fibre Channel HBAs in one arbitrated loop sharing the same storage devices, but
 not communicating with each other.
 Multi-Mode Fiber
 An optical waveguide in which light travels in multiple modes. Typical core/cladding sizes
 (measured in microns) are 50/125, 62.5/125, and 100/140.
 Multiplexing
 The process by which two or more signals are transmitted over a single communications
 channel.
 NetWare Peripheral Architecture (NWPA)
 Network architecture that provides a broader and more reliable driver support for third-party
 host adapters and storage devices. The NPWA separates NetWare driver support into two
 components: a Host Adapter Module (HAM), and a Custom Device Module (CDM). See also
 Custom Device Module and Host Adapter Module.
 nm
 Nanometer. A unit of measurement equal to one billionth of a meter. 10-9 meter.
 Non-OFC
 Non-Open Fiber Control. GLMs that do not contain OFC control but still guarantee laser
 emission levels to be below Class 1.
 OFC
 Open Fiber Control. A power monitoring/control system which continuously monitors the
 optical fiber link between two ports and prevents any laser emission from exceeding Class 1
 levels in the event of a break anywhere in the path.
 Optical Waveguide
 Dielectric waveguide with a core consisting of optically transparent material or low attenuation
 (usually silica glass) and with cladding consisting of optically transparent material of lower
 refractive index than that of the core. It is used for the transmission of signals with lightwaves
 and is frequently referred to as fiber.
 PCI Bus #
 An internal Peripheral Connect Interface bus number in a computer. PCI Bus # is set by the
 computer system’s BIOS, and in most cases, the number is zero.
 PCI Device #
 PCI slot number in a computer.
 Point-To-Point (PTP)
 A connection established between two specific locations, as between two buildings.




Host Bus Adapter for Windows and Linux Installation Guide                                         87
Glossary



 Protocol
 A data transmission convention encompassing timing, control, formatting, and data
 representation.
 SCSI
 Small Computer Systems Interface.
 SelectID
 Used to configure Seagate drives. A matrix for relating ALPA (hex) numbers to SelectID (hex)
 numbers.
 Shortwave
 Refers to length of the wave or frequency in the spectrum of light. 780 nm is the operating range
 of short wave lasers, while 1300nm describes the range of long wave lasers.
 Simplex Cable
 A term sometimes used for a single-fiber cable.
 Simplex Transmission
 Transmission in one direction only.
 Single-Mode Fiber
 An optical waveguide (or fiber) with a small core diameter in which only a single mode is
 capable of propagation. This type of fiber is particularly suitable for wideband transmission
 over large distances, since its bandwidth is limited only by chromatic dispersion.
 Topology
 The logical and/or physical arrangement of stations on a network.
 Transducer
 A device for converting energy from one form to another, such as optical energy to electrical
 energy.
 ULP
 Upper Level Protocol.
 Waveguide
 Structure that guides electromagnetic waves along its length. An optical fiber is an optical
 waveguide.
 Wavelength
 The distance between two crests of an electromagnetic waveform.




88                                              Host Bus Adapter for Windows and Linux Installation Guide
index


A                                                                E
A7298A host bus adapter See HBAs                                 equipment symbols 10
agency approvals 21
Al_PA addresses, table of 76                                     F
audience 8                                                       fabric device mapping 57
authorized reseller, HP 13                                       FCC Compliance notice 79
                                                                 Federal Communications Commission notice 81
B
Boot BIOS                                                        G
  definition 19                                                  getting help 13

C                                                                H
CmdStat values 54                                                HBAs
configuration                                                      agency approvals 21
  guidelines for HBAs 29                                           configuration guidelines 29
                                                 Index




  utilities 65                                                     installation overview 23
                                                         Index




conventions                                                        installation procedure 26
  document 9                                                       installation requirements 24
  equipment symbols 10                                             POST LED results 50
  text symbols 9                                                   product description 15
                                                                   recording reference numbers 25
D                                                                  restarting 77
diagnostic utilities 65                                            standards 20
document                                                           verifying installation 28
   conventions 9                                                   viewing parameters 71
   related documentation 8                                       help, obtaining 13
DOS Diagnostic utility                                           HP
   installing 66                                                   authorized reseller 13
   main menu 69                                                    storage website 13
   overview 66                                                     technical support 13
   preliminary analysis with 67
driver parameters, table of 73

Host Bus Adapter for Windows and Linux Installation Guide                                                89
Index



I                                                       SCSI Miniport drivers
installation                                               event log codes 52
   DOS Diagnostic utility 66                               installing on Windows Server 2003 32
   HBA overview 23                                         overview 31
   HBA requirements 24                                     removing from Windows Server 2003 33
   HBAs 26                                                 Windows Server 2003 system requirements
   verifying HBA installation 28                             32
                                                        showing HBA information 77
L                                                       standards, for HBAs 20
                                                        symbols in text 9
LightPulse Utility/NT
                                                        symbols on equipment 10
   input and output files 77
                                                        system requirements
   modifying driver parameters 73, 76, 77
                                                           HBA installation 24
   modifying test options 77
   overview 71
                                                        T
   restarting HBAs 77
   showing HBA information 77                           technical support, HP 13
   viewing HBA parameters 71                            test options, modifying 77
lputilnt, See LightPulse Utility/NT 71                  text symbols 9
                                                        troubleshooting
M                                                          CmdStat values 54
                                                           fabric device mapping 57
mapping
                                                           parameter error values 55
  fabric device 57
                                                           private loop device mapping 57
  private loop device 57
                                                           SCSI address mapping 57
  SCSI address 57
                                                           SCSI Miniport driver event logs 52
                                                           using POST LED results 50
P
                                                           Windows Event Viewer 51
parameter error values 55
POST LED indicators, verifying HBA installation         U
 28, 50
                                                        utilities
private loop device mapping, table of 58
                                                           DOS Diagnostic 66
                                                           LightPulse Utility/NT 71
R
                                                           overview 65
rack stability, warning 12
reference numbers 25                                    V
regulatory compliance notices
                                                        viewing HBA parameters 71
   FCC Compliance 79
   Federal Communications Commission 81
                                                        W
related documentation 8
                                                        warning
S                                                         rack stability 12
                                                          symbols on equipment 10
SCSI address mapping 57


90                                                Host Bus Adapter for Windows and Linux Installation Guide
Index



websites                                                        removing 33
  HP storage 13                                                 system requirements 32
Windows Event log 51
Windows Event Viewer 51                                     X
Windows Server 2003                                         x86DNLD, See DOS Diagnostic utility 66
  SCSI Miniport drivers
    installing 32




Host Bus Adapter for Windows and Linux Installation Guide                                              91
Index




92      Host Bus Adapter for Windows and Linux Installation Guide
Ad

More Related Content

What's hot (19)

Reseller's Guide
Reseller's GuideReseller's Guide
Reseller's Guide
webhostingguy
 
Pcb123v4 manual
Pcb123v4 manualPcb123v4 manual
Pcb123v4 manual
Rene Rodriguez
 
Plesk 8.1 for Linux/UNIX
Plesk 8.1 for Linux/UNIXPlesk 8.1 for Linux/UNIX
Plesk 8.1 for Linux/UNIX
webhostingguy
 
PANOS 4.1 Administrators Guide
PANOS 4.1 Administrators GuidePANOS 4.1 Administrators Guide
PANOS 4.1 Administrators Guide
Altaware, Inc.
 
C2675m c
C2675m cC2675m c
C2675m c
hungvv616
 
Su se linux-adminguide-9.0.0.0x86
Su se linux-adminguide-9.0.0.0x86Su se linux-adminguide-9.0.0.0x86
Su se linux-adminguide-9.0.0.0x86
Mohan Kumaresan
 
Grundfos Wincaps Manual Guide
Grundfos Wincaps Manual GuideGrundfos Wincaps Manual Guide
Grundfos Wincaps Manual Guide
SERDAR BELBAĞ
 
End note
End noteEnd note
End note
Rapassak Hetthong
 
Ppm7.5 demand cg
Ppm7.5 demand cgPpm7.5 demand cg
Ppm7.5 demand cg
indiatechnopark
 
HC100 - Manual da Impressora
HC100 - Manual da ImpressoraHC100 - Manual da Impressora
HC100 - Manual da Impressora
UseZ
 
Erpi admin 11123510[1] by иссам неязын issam hejazin
Erpi admin 11123510[1] by иссам неязын issam hejazinErpi admin 11123510[1] by иссам неязын issam hejazin
Erpi admin 11123510[1] by иссам неязын issam hejazin
Issam Hejazin
 
인터맥프린터 Intermec PX4i PX6i 열전사감열 RFID 산업용 바코드프린터 매뉴얼
인터맥프린터 Intermec PX4i PX6i 열전사감열 RFID 산업용 바코드프린터 매뉴얼인터맥프린터 Intermec PX4i PX6i 열전사감열 RFID 산업용 바코드프린터 매뉴얼
인터맥프린터 Intermec PX4i PX6i 열전사감열 RFID 산업용 바코드프린터 매뉴얼
HION IT
 
Epo 450 product_guide_en-us
Epo 450 product_guide_en-usEpo 450 product_guide_en-us
Epo 450 product_guide_en-us
lvaloto
 
Configuration of sas 9.1.3
Configuration of sas 9.1.3Configuration of sas 9.1.3
Configuration of sas 9.1.3
satish090909
 
Nsr Userguide
Nsr UserguideNsr Userguide
Nsr Userguide
kerklaanm
 
Guide citrix presentation server™ - client for java administrator’s
Guide   citrix presentation server™ - client for java administrator’sGuide   citrix presentation server™ - client for java administrator’s
Guide citrix presentation server™ - client for java administrator’s
xKinAnx
 
Creating a VMware Software-Defined Data Center Reference Architecture
Creating a VMware Software-Defined Data Center Reference Architecture Creating a VMware Software-Defined Data Center Reference Architecture
Creating a VMware Software-Defined Data Center Reference Architecture
EMC
 
MK-99DF8208-03
MK-99DF8208-03MK-99DF8208-03
MK-99DF8208-03
Robert Marburg
 
Data source integration guide for HP Performance Agent
Data source integration guide for HP Performance AgentData source integration guide for HP Performance Agent
Data source integration guide for HP Performance Agent
hernajes
 
Plesk 8.1 for Linux/UNIX
Plesk 8.1 for Linux/UNIXPlesk 8.1 for Linux/UNIX
Plesk 8.1 for Linux/UNIX
webhostingguy
 
PANOS 4.1 Administrators Guide
PANOS 4.1 Administrators GuidePANOS 4.1 Administrators Guide
PANOS 4.1 Administrators Guide
Altaware, Inc.
 
Su se linux-adminguide-9.0.0.0x86
Su se linux-adminguide-9.0.0.0x86Su se linux-adminguide-9.0.0.0x86
Su se linux-adminguide-9.0.0.0x86
Mohan Kumaresan
 
Grundfos Wincaps Manual Guide
Grundfos Wincaps Manual GuideGrundfos Wincaps Manual Guide
Grundfos Wincaps Manual Guide
SERDAR BELBAĞ
 
HC100 - Manual da Impressora
HC100 - Manual da ImpressoraHC100 - Manual da Impressora
HC100 - Manual da Impressora
UseZ
 
Erpi admin 11123510[1] by иссам неязын issam hejazin
Erpi admin 11123510[1] by иссам неязын issam hejazinErpi admin 11123510[1] by иссам неязын issam hejazin
Erpi admin 11123510[1] by иссам неязын issam hejazin
Issam Hejazin
 
인터맥프린터 Intermec PX4i PX6i 열전사감열 RFID 산업용 바코드프린터 매뉴얼
인터맥프린터 Intermec PX4i PX6i 열전사감열 RFID 산업용 바코드프린터 매뉴얼인터맥프린터 Intermec PX4i PX6i 열전사감열 RFID 산업용 바코드프린터 매뉴얼
인터맥프린터 Intermec PX4i PX6i 열전사감열 RFID 산업용 바코드프린터 매뉴얼
HION IT
 
Epo 450 product_guide_en-us
Epo 450 product_guide_en-usEpo 450 product_guide_en-us
Epo 450 product_guide_en-us
lvaloto
 
Configuration of sas 9.1.3
Configuration of sas 9.1.3Configuration of sas 9.1.3
Configuration of sas 9.1.3
satish090909
 
Nsr Userguide
Nsr UserguideNsr Userguide
Nsr Userguide
kerklaanm
 
Guide citrix presentation server™ - client for java administrator’s
Guide   citrix presentation server™ - client for java administrator’sGuide   citrix presentation server™ - client for java administrator’s
Guide citrix presentation server™ - client for java administrator’s
xKinAnx
 
Creating a VMware Software-Defined Data Center Reference Architecture
Creating a VMware Software-Defined Data Center Reference Architecture Creating a VMware Software-Defined Data Center Reference Architecture
Creating a VMware Software-Defined Data Center Reference Architecture
EMC
 
Data source integration guide for HP Performance Agent
Data source integration guide for HP Performance AgentData source integration guide for HP Performance Agent
Data source integration guide for HP Performance Agent
hernajes
 

Similar to hp StorageWorks host bus adapter for Windows and Linux ... (20)

User Guide En 7435
User Guide En 7435User Guide En 7435
User Guide En 7435
jkuehner
 
Hfm install
Hfm installHfm install
Hfm install
Raghuram Pavuluri
 
Manual CV41
Manual  CV41Manual  CV41
Manual CV41
Codeprint Soluçoes em Identificaçao e Captura de Ddos
 
software-eng.pdf
software-eng.pdfsoftware-eng.pdf
software-eng.pdf
fellahi1
 
Cisco routers for the small business a practical guide for it professionals...
Cisco routers for the small business   a practical guide for it professionals...Cisco routers for the small business   a practical guide for it professionals...
Cisco routers for the small business a practical guide for it professionals...
Mark Smith
 
sum2_abap_unix_hana.pdf
sum2_abap_unix_hana.pdfsum2_abap_unix_hana.pdf
sum2_abap_unix_hana.pdf
ssuser9f920a1
 
Manual CV51
Manual CV51Manual CV51
Manual CV51
Codeprint Soluçoes em Identificaçao e Captura de Ddos
 
Sap setup guide
Sap setup guideSap setup guide
Sap setup guide
Arnaldo Aguilar
 
인터맥산업용PC Intermec CV61 12.1인치 차량탑재용 산업용패널PC 매뉴얼
인터맥산업용PC Intermec CV61 12.1인치 차량탑재용 산업용패널PC 매뉴얼인터맥산업용PC Intermec CV61 12.1인치 차량탑재용 산업용패널PC 매뉴얼
인터맥산업용PC Intermec CV61 12.1인치 차량탑재용 산업용패널PC 매뉴얼
HION IT
 
Hp man ppm9.20_whats_new_pdf
Hp man ppm9.20_whats_new_pdfHp man ppm9.20_whats_new_pdf
Hp man ppm9.20_whats_new_pdf
ugunal
 
Dns320 manual 100
Dns320 manual 100Dns320 manual 100
Dns320 manual 100
markvw3
 
허니웰프린터 Honeywell PC42t 열전사감열 데스크탑 바코드프린터 매뉴얼
허니웰프린터 Honeywell PC42t 열전사감열 데스크탑 바코드프린터 매뉴얼허니웰프린터 Honeywell PC42t 열전사감열 데스크탑 바코드프린터 매뉴얼
허니웰프린터 Honeywell PC42t 열전사감열 데스크탑 바코드프린터 매뉴얼
HION IT
 
Presentation data center deployment guide
Presentation   data center deployment guidePresentation   data center deployment guide
Presentation data center deployment guide
xKinAnx
 
인터맥프린터 Intermec PM4i 열전사감열 RFID 바코드프린터 산업용프린터 매뉴얼
인터맥프린터 Intermec PM4i 열전사감열 RFID 바코드프린터 산업용프린터 매뉴얼인터맥프린터 Intermec PM4i 열전사감열 RFID 바코드프린터 산업용프린터 매뉴얼
인터맥프린터 Intermec PM4i 열전사감열 RFID 바코드프린터 산업용프린터 매뉴얼
HION IT
 
인터맥프린터 Intermec PB51 감열 모바일프린터 매뉴얼
인터맥프린터 Intermec PB51 감열 모바일프린터 매뉴얼인터맥프린터 Intermec PB51 감열 모바일프린터 매뉴얼
인터맥프린터 Intermec PB51 감열 모바일프린터 매뉴얼
HION IT
 
인터맥프린터 Intermec PB50 감열 모바일프린터 매뉴얼
인터맥프린터 Intermec PB50 감열 모바일프린터 매뉴얼인터맥프린터 Intermec PB50 감열 모바일프린터 매뉴얼
인터맥프린터 Intermec PB50 감열 모바일프린터 매뉴얼
HION IT
 
Guia definitiva de shodan
Guia definitiva de shodanGuia definitiva de shodan
Guia definitiva de shodan
noc_313
 
Suse linux enterprise_server_15_x_for_sap_applications_configuration_guide_fo...
Suse linux enterprise_server_15_x_for_sap_applications_configuration_guide_fo...Suse linux enterprise_server_15_x_for_sap_applications_configuration_guide_fo...
Suse linux enterprise_server_15_x_for_sap_applications_configuration_guide_fo...
Jaleel Ahmed Gulammohiddin
 
Plesk 8.1 for Windows
Plesk 8.1 for WindowsPlesk 8.1 for Windows
Plesk 8.1 for Windows
webhostingguy
 
Plesk 8.1 for Windows
Plesk 8.1 for WindowsPlesk 8.1 for Windows
Plesk 8.1 for Windows
webhostingguy
 
User Guide En 7435
User Guide En 7435User Guide En 7435
User Guide En 7435
jkuehner
 
software-eng.pdf
software-eng.pdfsoftware-eng.pdf
software-eng.pdf
fellahi1
 
Cisco routers for the small business a practical guide for it professionals...
Cisco routers for the small business   a practical guide for it professionals...Cisco routers for the small business   a practical guide for it professionals...
Cisco routers for the small business a practical guide for it professionals...
Mark Smith
 
sum2_abap_unix_hana.pdf
sum2_abap_unix_hana.pdfsum2_abap_unix_hana.pdf
sum2_abap_unix_hana.pdf
ssuser9f920a1
 
인터맥산업용PC Intermec CV61 12.1인치 차량탑재용 산업용패널PC 매뉴얼
인터맥산업용PC Intermec CV61 12.1인치 차량탑재용 산업용패널PC 매뉴얼인터맥산업용PC Intermec CV61 12.1인치 차량탑재용 산업용패널PC 매뉴얼
인터맥산업용PC Intermec CV61 12.1인치 차량탑재용 산업용패널PC 매뉴얼
HION IT
 
Hp man ppm9.20_whats_new_pdf
Hp man ppm9.20_whats_new_pdfHp man ppm9.20_whats_new_pdf
Hp man ppm9.20_whats_new_pdf
ugunal
 
Dns320 manual 100
Dns320 manual 100Dns320 manual 100
Dns320 manual 100
markvw3
 
허니웰프린터 Honeywell PC42t 열전사감열 데스크탑 바코드프린터 매뉴얼
허니웰프린터 Honeywell PC42t 열전사감열 데스크탑 바코드프린터 매뉴얼허니웰프린터 Honeywell PC42t 열전사감열 데스크탑 바코드프린터 매뉴얼
허니웰프린터 Honeywell PC42t 열전사감열 데스크탑 바코드프린터 매뉴얼
HION IT
 
Presentation data center deployment guide
Presentation   data center deployment guidePresentation   data center deployment guide
Presentation data center deployment guide
xKinAnx
 
인터맥프린터 Intermec PM4i 열전사감열 RFID 바코드프린터 산업용프린터 매뉴얼
인터맥프린터 Intermec PM4i 열전사감열 RFID 바코드프린터 산업용프린터 매뉴얼인터맥프린터 Intermec PM4i 열전사감열 RFID 바코드프린터 산업용프린터 매뉴얼
인터맥프린터 Intermec PM4i 열전사감열 RFID 바코드프린터 산업용프린터 매뉴얼
HION IT
 
인터맥프린터 Intermec PB51 감열 모바일프린터 매뉴얼
인터맥프린터 Intermec PB51 감열 모바일프린터 매뉴얼인터맥프린터 Intermec PB51 감열 모바일프린터 매뉴얼
인터맥프린터 Intermec PB51 감열 모바일프린터 매뉴얼
HION IT
 
인터맥프린터 Intermec PB50 감열 모바일프린터 매뉴얼
인터맥프린터 Intermec PB50 감열 모바일프린터 매뉴얼인터맥프린터 Intermec PB50 감열 모바일프린터 매뉴얼
인터맥프린터 Intermec PB50 감열 모바일프린터 매뉴얼
HION IT
 
Guia definitiva de shodan
Guia definitiva de shodanGuia definitiva de shodan
Guia definitiva de shodan
noc_313
 
Suse linux enterprise_server_15_x_for_sap_applications_configuration_guide_fo...
Suse linux enterprise_server_15_x_for_sap_applications_configuration_guide_fo...Suse linux enterprise_server_15_x_for_sap_applications_configuration_guide_fo...
Suse linux enterprise_server_15_x_for_sap_applications_configuration_guide_fo...
Jaleel Ahmed Gulammohiddin
 
Plesk 8.1 for Windows
Plesk 8.1 for WindowsPlesk 8.1 for Windows
Plesk 8.1 for Windows
webhostingguy
 
Plesk 8.1 for Windows
Plesk 8.1 for WindowsPlesk 8.1 for Windows
Plesk 8.1 for Windows
webhostingguy
 
Ad

More from webhostingguy (20)

File Upload
File UploadFile Upload
File Upload
webhostingguy
 
Running and Developing Tests with the Apache::Test Framework
Running and Developing Tests with the Apache::Test FrameworkRunning and Developing Tests with the Apache::Test Framework
Running and Developing Tests with the Apache::Test Framework
webhostingguy
 
MySQL and memcached Guide
MySQL and memcached GuideMySQL and memcached Guide
MySQL and memcached Guide
webhostingguy
 
Novell® iChain® 2.3
Novell® iChain® 2.3Novell® iChain® 2.3
Novell® iChain® 2.3
webhostingguy
 
Load-balancing web servers Load-balancing web servers
Load-balancing web servers Load-balancing web serversLoad-balancing web servers Load-balancing web servers
Load-balancing web servers Load-balancing web servers
webhostingguy
 
SQL Server 2008 Consolidation
SQL Server 2008 ConsolidationSQL Server 2008 Consolidation
SQL Server 2008 Consolidation
webhostingguy
 
What is mod_perl?
What is mod_perl?What is mod_perl?
What is mod_perl?
webhostingguy
 
What is mod_perl?
What is mod_perl?What is mod_perl?
What is mod_perl?
webhostingguy
 
Master Service Agreement
Master Service AgreementMaster Service Agreement
Master Service Agreement
webhostingguy
 
Notes8
Notes8Notes8
Notes8
webhostingguy
 
PHP and MySQL PHP Written as a set of CGI binaries in C in ...
PHP and MySQL PHP Written as a set of CGI binaries in C in ...PHP and MySQL PHP Written as a set of CGI binaries in C in ...
PHP and MySQL PHP Written as a set of CGI binaries in C in ...
webhostingguy
 
Dell Reference Architecture Guide Deploying Microsoft® SQL ...
Dell Reference Architecture Guide Deploying Microsoft® SQL ...Dell Reference Architecture Guide Deploying Microsoft® SQL ...
Dell Reference Architecture Guide Deploying Microsoft® SQL ...
webhostingguy
 
Managing Diverse IT Infrastructure
Managing Diverse IT InfrastructureManaging Diverse IT Infrastructure
Managing Diverse IT Infrastructure
webhostingguy
 
Web design for business.ppt
Web design for business.pptWeb design for business.ppt
Web design for business.ppt
webhostingguy
 
IT Power Management Strategy
IT Power Management Strategy IT Power Management Strategy
IT Power Management Strategy
webhostingguy
 
Excel and SQL Quick Tricks for Merchandisers
Excel and SQL Quick Tricks for MerchandisersExcel and SQL Quick Tricks for Merchandisers
Excel and SQL Quick Tricks for Merchandisers
webhostingguy
 
OLUG_xen.ppt
OLUG_xen.pptOLUG_xen.ppt
OLUG_xen.ppt
webhostingguy
 
Parallels Hosting Products
Parallels Hosting ProductsParallels Hosting Products
Parallels Hosting Products
webhostingguy
 
Microsoft PowerPoint presentation 2.175 Mb
Microsoft PowerPoint presentation 2.175 MbMicrosoft PowerPoint presentation 2.175 Mb
Microsoft PowerPoint presentation 2.175 Mb
webhostingguy
 
Installation of MySQL 5.1 Cluster Software on the Solaris 10 ...
Installation of MySQL 5.1 Cluster Software on the Solaris 10 ...Installation of MySQL 5.1 Cluster Software on the Solaris 10 ...
Installation of MySQL 5.1 Cluster Software on the Solaris 10 ...
webhostingguy
 
Running and Developing Tests with the Apache::Test Framework
Running and Developing Tests with the Apache::Test FrameworkRunning and Developing Tests with the Apache::Test Framework
Running and Developing Tests with the Apache::Test Framework
webhostingguy
 
MySQL and memcached Guide
MySQL and memcached GuideMySQL and memcached Guide
MySQL and memcached Guide
webhostingguy
 
Novell® iChain® 2.3
Novell® iChain® 2.3Novell® iChain® 2.3
Novell® iChain® 2.3
webhostingguy
 
Load-balancing web servers Load-balancing web servers
Load-balancing web servers Load-balancing web serversLoad-balancing web servers Load-balancing web servers
Load-balancing web servers Load-balancing web servers
webhostingguy
 
SQL Server 2008 Consolidation
SQL Server 2008 ConsolidationSQL Server 2008 Consolidation
SQL Server 2008 Consolidation
webhostingguy
 
Master Service Agreement
Master Service AgreementMaster Service Agreement
Master Service Agreement
webhostingguy
 
PHP and MySQL PHP Written as a set of CGI binaries in C in ...
PHP and MySQL PHP Written as a set of CGI binaries in C in ...PHP and MySQL PHP Written as a set of CGI binaries in C in ...
PHP and MySQL PHP Written as a set of CGI binaries in C in ...
webhostingguy
 
Dell Reference Architecture Guide Deploying Microsoft® SQL ...
Dell Reference Architecture Guide Deploying Microsoft® SQL ...Dell Reference Architecture Guide Deploying Microsoft® SQL ...
Dell Reference Architecture Guide Deploying Microsoft® SQL ...
webhostingguy
 
Managing Diverse IT Infrastructure
Managing Diverse IT InfrastructureManaging Diverse IT Infrastructure
Managing Diverse IT Infrastructure
webhostingguy
 
Web design for business.ppt
Web design for business.pptWeb design for business.ppt
Web design for business.ppt
webhostingguy
 
IT Power Management Strategy
IT Power Management Strategy IT Power Management Strategy
IT Power Management Strategy
webhostingguy
 
Excel and SQL Quick Tricks for Merchandisers
Excel and SQL Quick Tricks for MerchandisersExcel and SQL Quick Tricks for Merchandisers
Excel and SQL Quick Tricks for Merchandisers
webhostingguy
 
Parallels Hosting Products
Parallels Hosting ProductsParallels Hosting Products
Parallels Hosting Products
webhostingguy
 
Microsoft PowerPoint presentation 2.175 Mb
Microsoft PowerPoint presentation 2.175 MbMicrosoft PowerPoint presentation 2.175 Mb
Microsoft PowerPoint presentation 2.175 Mb
webhostingguy
 
Installation of MySQL 5.1 Cluster Software on the Solaris 10 ...
Installation of MySQL 5.1 Cluster Software on the Solaris 10 ...Installation of MySQL 5.1 Cluster Software on the Solaris 10 ...
Installation of MySQL 5.1 Cluster Software on the Solaris 10 ...
webhostingguy
 
Ad

hp StorageWorks host bus adapter for Windows and Linux ...

  • 1. installation guide hp StorageWorks host bus adapter for Windows and Linux Third Edition (April 2003) Part Number: AA–RTD1C–TE This guide describes how to install, configure, and use the diagnostic utilities for the HP StorageWorks A7298A host bus adapter for Windows Server 2003 and Linux platforms.
  • 2. © Hewlett-Packard Company, 2003. All rights reserved. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of Hewlett-Packard. The information contained in this document is subject to change without notice. Intel® is a U.S. registered trademarks of Intel Corporation. Microsoft®, MS-DOS®, MS Windows®, Windows®, and Windows NT® are U.S. registered trademarks of Microsoft Corporation. Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information is provided “as is” without warranty of any kind and is subject to change without notice. The warranties for Hewlett-Packard Company products are set forth in the express limited warranty statements for such products. Nothing herein should be construed as constituting an additional warranty. Printed in the U.S.A. Host Bus Adapter for Windows and Linux Installation Guide Third Edition (April 2003) Part Number: AA–RTD1C–TE
  • 3. contents Contents About this Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Intended Audience . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Text Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Equipment Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Rack Stability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Getting Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 HP Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 HP Storage Website . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 HP Authorized Reseller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Performance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Boot BIOS Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Enabling Boot BIOS and External Boot . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Standards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Agency Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23 Installation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Recording Reference Numbers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Installing the HBA into a Computer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Verifying the Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Configuration Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Host Bus Adapter for Windows and Linux Installation Guide 3
  • 4. Contents 3 Installing the SCSI Miniport Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Windows Server 2003 Device Driver Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Windows Server 2003 System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Installing the Windows Server 2003 SCSI Miniport Driver . . . . . . . . . . . . . . . . . . . . . . 32 Removing the Windows Server 2003 SCSI Device Driver . . . . . . . . . . . . . . . . . . . . . . . 33 Linux Device Driver Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Linux System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Installing the Linux Driver Using a Tar File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Installing the Linux Driver Using an RPM File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Building the Driver as a Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Loading the Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Loading the Driver Manually. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Loading the Driver Through the RAM Disk Image. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Building the Driver Into the Kernel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 SCSI Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 IP Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Setting up and Running Diagnostic Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Installing the Latest Version of HBA API and Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 POST Conditions and Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Using The Event Viewer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Windows Miniport Event Log Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 SCSI Address Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Fabric Device Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Private Loop Device Mapping for Windows Platforms. . . . . . . . . . . . . . . . . . . . . . . . . . 57 5 Diagnostic and Configuration Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 The DOS Diagnostic Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Starting the DOS Diagnostic Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66 Using the DOS Diagnostic Utility for Preliminary Testing . . . . . . . . . . . . . . . . . . . . . . . 67 DOS Diagnostic Utility Main Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 LightPulse Utility/NT Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 View HBA Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Maintaining HBA Firmware Revision Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 Modify Diagnostic Driver Parameters in the Windows Registry . . . . . . . . . . . . . . . . . . 72 Modify the Driver Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 4 Host Bus Adapter for Windows and Linux Installation Guide
  • 5. Contents Test Host Bus Adapters (For lputilnt Only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Modify Test Options (For lputilnt Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Reset Host Bus Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Input/Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Show Host Bus Adapter Info (For lputilnt Only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Quit the LightPulse Utility/NT Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 A Regulatory Compliance Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .79 FCC Compliance Information Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 Japanese Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Canadian Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Avis Canadien . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Federal Communications Commission Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Japanese Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Canadian Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Avis Canadien . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 Figures 1 Host Bus Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Tables 1 Document Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 2 Host Bus Adapter Diagram Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 3 Normal POST LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 4 Normal POST LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 5 SCSI Port Error Log Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 6 CmdStat Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 7 Parameter Error Values Valid only when CmdStat=0x3 . . . . . . . . . . . . . . . . . . . . . . . . . 55 8 Current Private Loop Device Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 9 DOS Diagnostic Utility Command Options. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 10 DOS Diagnosis Utility Main Menu Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 11 Driver Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 12 AL-PA Addresses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Host Bus Adapter for Windows and Linux Installation Guide 5
  • 6. Contents 6 Host Bus Adapter for Windows and Linux Installation Guide
  • 7. about this guide About this Guide This installation guide provides information to help you: ■ Install, configure, and Aboutthe diagnostic utilities for the HP StorageWorks use this Guide A7298A host bus adapter for Windows and Linux platforms. ■ Contact technical support for additional assistance. “About this Guide” topics include: ■ Overview, page 8 ■ Conventions, page 9 ■ Rack Stability, page 12 ■ Getting Help, page 13 Host Bus Adapter for Windows and Linux Installation Guide 7
  • 8. About this Guide Overview This section covers the following topics: ■ Intended Audience ■ Related Documentation Intended Audience This book is intended for use by system administrators who are experienced with the following: ■ Windows Server 2003 ■ Linux Red Hat Advanced Workstation v2.1 (Itanium processor) ■ Host bus adapters Related Documentation In addition to this guide, HP provides corresponding information: ■ hp StorageWorks release notes — host bus adapter for Windows and Linux 8 Host Bus Adapter for Windows and Linux Installation Guide
  • 9. About this Guide Conventions Conventions consist of the following: ■ Document Conventions ■ Text Symbols ■ Equipment Symbols Document Conventions The document conventions included in Table 1 apply in most cases. Table 1: Document Conventions Element Convention Cross-reference links Blue text: Figure 1 Key and field names, menu items, Bold buttons, and dialog box titles File names, application names, and text Italics emphasis User input, command and directory Monospace font names, and system responses (output COMMAND NAMES are uppercase and messages) monospace font unless they are case sensitive Variables <monospace, italic font> Website addresses Blue, underlined sans serif font text: http://www.hp.com Text Symbols The following symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily harm or death. Host Bus Adapter for Windows and Linux Installation Guide 9
  • 10. About this Guide Caution: Text set off in this manner indicates that failure to follow directions could result in damage to equipment or data. Note: Text set off in this manner presents commentary, sidelights, or interesting points of information. Equipment Symbols The following equipment symbols may be found on hardware for which this guide pertains. They have the following meanings. Any enclosed surface or area of the equipment marked with these symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of personal safety from electrical shock hazards, do not open this enclosure. Any RJ-45 receptacle marked with these symbols indicates a network interface connection. WARNING: To reduce the risk of electrical shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle. Any surface or area of the equipment marked with these symbols indicates the presence of a hot surface or hot component. Contact with this surface could result in injury. WARNING: To reduce the risk of personal safety from a hot component, allow the surface to cool before touching. 10 Host Bus Adapter for Windows and Linux Installation Guide
  • 11. About this Guide Power supplies or systems marked with these symbols indicate the presence of multiple sources of power. WARNING: To reduce the risk of personal safety from electrical shock, remove all power cords to completely disconnect power from the power supplies and systems. Any product or assembly marked with these symbols indicates that the component exceeds the recommended weight for one individual to handle safely. WARNING: To reduce the risk of personal safety or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. Host Bus Adapter for Windows and Linux Installation Guide 11
  • 12. About this Guide Rack Stability Rack stability protects personnel and equipment. WARNING: To reduce the risk of personal safety or damage to the equipment, be sure that: ■ The leveling jacks are extended to the floor. ■ The full weight of the rack rests on the leveling jacks. ■ In single rack installations, the stabilizing feet are attached to the rack. ■ In multiple rack installations, the racks are coupled. ■ Only one rack component is extended at any time. A rack may become unstable if more than one rack component is extended for any reason. 12 Host Bus Adapter for Windows and Linux Installation Guide
  • 13. About this Guide Getting Help If you still have a question after reading this guide, contact an HP authorized service provider or access our website: http://www.hp.com. HP Technical Support Telephone numbers for worldwide technical support are listed on the following HP website: http://www.hp.com/support/. From this website, select the country of origin. Note: For continuous quality improvement, calls may be recorded or monitored. Be sure to have the following information available before calling: ■ Technical support registration number (if applicable) ■ Product serial numbers ■ Product model names and numbers ■ Applicable error messages ■ Operating system type and revision level ■ Detailed, specific questions HP Storage Website The HP website has the latest information on this product, as well as the latest drivers. Access storage at: http://www.hp.com/country/us/eng/prodserv/ storage.html. From this website, select the appropriate product or solution. HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518 ■ In Canada, call 1-800-263-5868 ■ Elsewhere, see the HP website for locations and telephone numbers: http://www.hp.com. Host Bus Adapter for Windows and Linux Installation Guide 13
  • 14. About this Guide 14 Host Bus Adapter for Windows and Linux Installation Guide
  • 15. Introduction 1 1 This user guide provides information to help you install, configure, and use the diagnostic utilities for the HP StorageWorks A7298A host bus adapter for Windows and Linux platforms. Overview This introduction to the Host Bus Adapter (HBA) includes: ■ Product Description ■ Performance Specifications ■ Boot BIOS Specifications ■ Standards ■ Agency Approvals Host Bus Adapter for Windows and Linux Installation Guide 15
  • 16. Introduction Product Description The HBA has the following characteristics: ■ Robust suite of software supporting Windows Server 2003 and Linux Red Hat Advanced Workstation v2.1. ■ Optical small form factor (LC) interface LC Fibre connector. ■ Embedded optical short-wave laser, multi-mode Fibre Channel interface. ■ Designed using a single custom Application Specific Integrated Circuit (ASIC). The custom ASIC implements a very high performance, multi-class, multi-protocol Fibre Channel host adapter with a 64-bit PCI or PCI-X bus connection. ■ 66/100/133MHz PCI-X 1.0a and PCI 2.2 compatibility. ■ 266MIPs onboard processor, an embedded 1GB/2GB SERDES, and a high performance unified QDR SRAM. ■ Controlled by a 266 MHz, 32-bit Intel StrongARM RISC processor. 16 Host Bus Adapter for Windows and Linux Installation Guide
  • 17. Introduction Figure 1: Host Bus Adapter Table 2: Host Bus Adapter Diagram Description Figure Legend Description 1 Fibre Channel (LC) connectors. 2 POST LEDs indicators Note: See Table 3 and Table 4 for detailed descriptions. Host Bus Adapter for Windows and Linux Installation Guide 17
  • 18. Introduction Performance Specifications The PCI-X host bus adapter offers a highly integrated 2Gbps Fibre Channel HBA for use in servers based on either PCI or the latest PCI-X expansion bus. The features of this PCI-X based HBA provide the flexibility and broad interoperability needed for complex, highly scalable SANs. The HBA also features sophisticated hardware that provides superior performance in SANs and provides best in class server CPU offload. This exclusive hardware delivers low latency and high throughput in switched fabric, arbitrated loop, and clustered environments. Support for fiber optic cabling is provided through an embedded small form factor (LC) optical interface. The HBA is both ANSI Fibre Channel and PCI Local Bus Compliant and supports: ■ Simultaneous full duplex 2 Gbps PCI bus speed data transfers of 400 MBps ■ Full fabric support using F_PORT and FL_Port connections ■ Full fabric boot support in x86 environments to multiple LUNs ■ FC-Tape (FC-2) devices ■ Point-to-point arbitrated-loop, and switch fabric FC connections ■ Storage protocol ■ Fibre Channel class 2 and 3 ■ Automatic speed negotiation and topology detection ■ End-to-end parity protection for high data integrity Collectively, these characteristics create a high-performance Fibre Channel HBA. 18 Host Bus Adapter for Windows and Linux Installation Guide
  • 19. Introduction Boot BIOS Specifications Boot BIOS is a set of x86 instructions in the Host Bus Adapter (HBA) flash ROM that lets you designate a Fibre Channel attached drive as the boot drive. Boot BIOS works with the existing system BIOS on Intel Pentium class PCI system boards. Boot BIOS supports: ■ Multiple topologies: Fabric Point-to-Point and FC-AL Private Loop ■ Multiple boot compliance ■ Supports Enhanced Disk Driver Services (EDD) Version 3.0 ■ A maximum of four Fibre Channel HBAs per server, depending on which StorageWorks product you are using. ■ Up to 256 LUNs, with up to eight LUN entries per target ID ■ Detecting up to 99 devices per HBA ■ Displaying a maximum of 16 devices during the boot process Enabling Boot BIOS and External Boot All HBAs have the BIOS firmware installed as a factory default. However, the BIOS functionality is not enabled. In addition, you can optionally eliminate server-based, internal boot devices and boot from an external device to improve performance. Refer to the BIOS Readme file on the HBA software kit as well as the documentation for your StorageWorks product for the following up-to-date information for enabling boot BIOS and external Boot: ■ Enabling boot BIOS on an HBA ■ Attaching HBAs in a supported configuration ■ Enabling external boot for supported configurations In addition, the HP website has the latest information on Boot BIOS upgrades. Access the HP website at: http://www.hp.com/support/itaniumservers. Host Bus Adapter for Windows and Linux Installation Guide 19
  • 20. Introduction Standards The HBA conforms to the following standards: ■ ANSI Fibre Channel FC-PH, Revision 4.3 ■ ANSI Fibre Channel FC-AL, Revision 4.5 ■ PCI Local Bus, Revisions 2.1 and 2.2 ■ Fibre Channel Class 1, 2, 3 20 Host Bus Adapter for Windows and Linux Installation Guide
  • 21. Introduction Agency Approvals The HBA has the following agency approvals: ■ CFR Title 21, Laser AEL Class 1, FDA/CDRH ■ UL recognized to UL1950 ■ CUR recognized to CSA22.2, No.950 ■ IEC 950 (1991) + Amendments 1, 2, 3, 4, and 11 ■ EN60950 (1992) + Amendments 1, 2, 3, 4, and 11 ■ EN68025-1 (1994) + Amendment 11 ■ EN68025-2 (1994) ■ TUV certified to EN60950 ■ FCC Rules, CFR Title 47, Part 15, Subpart B, Class A ■ Industry Canada, ICES-003, Class A ■ EN55022 (1998)/CISPR22 (1997) Class A ■ EN55024 (1998) ■ European Union Low Voltage Directive 73/23/EEC ■ CE-Marking Directive 93/68/EEC (CE Mark) ■ EMC Directive 89/336/EEC (as amended by 92/31/EEC) ■ Australian EMC Framework (C-Tick Mark) ■ AS/NZS 3548:1995, Class A ■ VCCI, Class A Host Bus Adapter for Windows and Linux Installation Guide 21
  • 22. Introduction 22 Host Bus Adapter for Windows and Linux Installation Guide
  • 23. Installation 2 2 Installation Overview This chapter provides step-by-step instructions for installing the HP StorageWorks A7298A Host Bus Adapter (HBA) including: ■ Hardware Requirements ■ Recording Reference Numbers ■ Installing the HBA into a Computer ■ Verifying the Installation ■ Configuration Guidelines This chapter also provides information on installation guidelines and supported configurations for the operating systems. IMPORTANT: The HBA contains static-sensitive components. Comply with Electrostatic Discharge (ESD) procedures. Host Bus Adapter for Windows and Linux Installation Guide 23
  • 24. Installation Hardware Requirements The system hardware requirements for installing the HBA include: ■ A host computer that provides 3.3VDC PCI and PCI-X bus power ■ One open 64-bit 33/66 MHz PCI or 66/100/133 MHz PCI-X bus slot with either a 3.3 or a 5.0 VDC signaling interface ■ Multimode fiber optic cable with LC connector, used with short-wave lasers 24 Host Bus Adapter for Windows and Linux Installation Guide
  • 25. Installation Recording Reference Numbers Each HBA ships with a unique address identifier that is stored in flash memory. Fibre Channel industry standards issue two unique identifiers: WorldWide Port Name (WWPN) and Node Name (NN), each of which is derived from the HBA’s IEEE address. Combined, the WWPN and NN create the WorldWide Name (WWN) which is an 8-byte field that uniquely identifies an HBA on a FC circuit. The WWN address and serial number are clearly marked on the HBA. Record the addresses on the lines below for future reference. Note: The WWN is a static identifier that cannot be changed. IEEE address: __________________________________________________ Serial number: __________________________________________________ Host Bus Adapter for Windows and Linux Installation Guide 25
  • 26. Installation Installing the HBA into a Computer Following is the procedure for installing the HBA into a computer. WARNING: Be sure to observe the ESD precautions for this procedure. 1. Make sure the computer is powered off. 2. Remove the screws on the computer cover, and then remove the cover. 3. Wearing a static wrist strap, remove the blank panel from an empty 64-bit PCI or PCI-X bus slot. Compare the removed panel to the bracket on the host bus adapter. Follow steps 4-7 to change the bracket if they are different sizes. Note: The host bus adapter comes with a standard PCI bracket installed. The low-profile mounting bracket is shorter than the standard bracket; approximately 3.11 in. (7.9cm) compared to 4.75 in. (12.06 cm) long. 4. Remove the mounting bracket screws from the top of the host bus adapter. 5. Remove the bracket and store it for future use. 6. Align the new mounting bracket tabs with the holes in the HBA. Note: Be careful not to push the bracket past the transceiver housing's grounding tabs. 7. Replace the screws that attach the HBA to the bracket. 8. Insert the HBA into the empty PCI or PCI-X bus slot; press firmly until it is seated securely. 9. Secure the HBA mounting bracket to the computer panel with the panel screws. 10. Replace the computer cover and secure it using the previously removed screws. 26 Host Bus Adapter for Windows and Linux Installation Guide
  • 27. Installation 11. Attach media: a. Connect the fiber optic cable to the LC connector on the HBA. b. Connect the other end of the cable to the Fibre Channel device. Note: The HBA does not allow normal data transmission on an optical link unless it is connected to a similar or compatible laser product. That is, both products are multimode to multimode. Host Bus Adapter for Windows and Linux Installation Guide 27
  • 28. Installation Verifying the Installation To verify the HBA is properly installed and is operating: 1. Turn on the computer. 2. At power up, observe the POST LED indicators on the HBA. The position of the POST LED indicators is defined in Figure 1 and Table 2 of this guide. The green LED indicates power functions and the amber LED signifies port activity. The amber LED blinks at all times during normal operation. Table 3 lists normal LED indications. Table 3: Normal POST LED Indicators Amber LED (L1) Green LED (L2) State Off Off Wake-up failure (dead board) On Off POST failure (dead board) Slow blink (1 Hz) Off Wake-up failure (dead board) Fast blink (4 Hz) Off Failure in POST (dead board) Flashing (irregular) Off POST processing in progress Off On Failure while functioning On On Failure while functioning Slow blink (1 Hz) On Normal—1 Gb link rate Fast blink (4 Hz) On Normal—2 Gb link rate Off Blink (1 Hz) Normal—link down or not yet started 28 Host Bus Adapter for Windows and Linux Installation Guide
  • 29. Installation Configuration Guidelines The software for loading the driver also contains the default registry parameter settings that are loaded as part of the driver installation. Consult the following sources for any restriction and for information on supported configurations specific to your operating system and topology. ■ Release Notes ■ HP Website at: http://www.hp.com/support/itaniumservers. Host Bus Adapter for Windows and Linux Installation Guide 29
  • 30. Installation 30 Host Bus Adapter for Windows and Linux Installation Guide
  • 31. Installing the SCSI Miniport Driver 3 3 Introduction This chapter contains step-by-step instructions for installing the Windows Server 2003 and Linux SCSI Miniport drivers. System managers must be familiar with the operating system under which the PCI or PCI-X-to-Fibre Channel Host Bus Adapter (HBA) is to operate. System managers must also have access to standard system documentation. The software kit that is included with the HBA contains the latest version of the HBA’s files and drivers at the time of shipment. Software files are updated periodically and can be obtained from the HP website at: http://www.hp.com/support/itaniumservers. Note: This chapter describes the steps for installing the device driver and for accessing Fibre Channel storage devices. For other configuration changes, see Chapter 5, Modify Diagnostic Driver Parameters in the Windows Registry. Host Bus Adapter for Windows and Linux Installation Guide 31
  • 32. Installing the SCSI Miniport Driver Windows Server 2003 Device Driver Installation This section describes the instructions for installing the Windows Server 2003 SCSI Miniport driver. Windows Server 2003 System Requirements Ensure that your system meets these minimum requirements: ■ Installed HBA ■ Ensure the HP Setup and Configuration CD for Itanium(R) 2-based servers is in the server or the driver has been downloaded from the web and copied to the server hard drive. ■ StorageWorks Fibre Channel Storage subsystem (interconnect device and storage device) Installing the Windows Server 2003 SCSI Miniport Driver This section contains the steps for installing the Windows Server 2003 SCSI Miniport device driver on a Windows Server 2003. From the Windows Server 2003 desktop: 1. Click Start > Settings > Control Panel. 2. Double-click Administrative Tools. 3. Double-click Computer Management. 4. Click Device Manager. 5. Open the SCSI and RAID controllers item in the list. 6. Choose the Drivers tab. 7. Choose Update Driver. 8. Choose Install the software automatically (Recommended) and click Next. 9. Click Finish. 10. Click Yes to restart Windows Server 2003. 11. Verify the device driver installation: a. Click Start > Settings > Control Panel. b. Double-click the System icon. c. Click Device Manager. 32 Host Bus Adapter for Windows and Linux Installation Guide
  • 33. Installing the SCSI Miniport Driver d. Verify that the SCSI Miniport driver is present and started. Removing the Windows Server 2003 SCSI Device Driver To remove the device driver from the Windows Server 2003 desktop: 1. Click Start > Settings > Control Panel. 2. Double-click the System icon. 3. Click Device Manager. 4. Open the SCSI and RAID controllers item in the list. 5. Click Remove. 6. Choose Yes to confirm. 7. Click OK. 8. Reboot the computer to restart Windows Server 2003. Host Bus Adapter for Windows and Linux Installation Guide 33
  • 34. Installing the SCSI Miniport Driver Linux Device Driver Installation This section describes the instructions for installing the Linux SCSI Miniport driver. Linux System Requirements Ensure that your system meets these minimum requirements: ■ Installed HBA ■ Linux Miniport driver and registry parameter file from the software kit provided with the HBA ■ Linux operating system ■ StorageWorks Fibre Channel Storage subsystem (interconnect device and storage device) 34 Host Bus Adapter for Windows and Linux Installation Guide
  • 35. Installing the SCSI Miniport Driver Installing the Linux Driver Using a Tar File To install the driver and boot the system, you must be running as root. 1. Enter the following command to create a temporary directory (for example, emlxtemp). # mkdir emlxtemp 2. Enter the following command to change directory to the temporary directory. # cd emlxtemp 3. Copy or download the device driver file to the temporary directory. 4. Enter the following command if the file is in the format filename.rpm.Z: # tar xvzf filename.tar.Z or else untar the driver file. # tar xvf filename.tar The package unzips to one SourceBuild directory. 5. Enter the following command to change directory to the SourceBuild directory. # cd SourceBuild This becomes the driver_installation_directory. Host Bus Adapter for Windows and Linux Installation Guide 35
  • 36. Installing the SCSI Miniport Driver Installing the Linux Driver Using an RPM File To install the driver and boot the system, you must be running as root. 1. Enter the following command to create a temporary directory (for example, emlxtemp). # mkdir emlxtemp 2. Enter the following command to change directory to the temporary directory. # cd emlxtemp 3. Copy or download the device driver RPM file to the temporary directory. 4. Enter the following command if the file is in the format filename.rpm.Z and kernel source files are installed: # uncompress filename.rpm.Z 5. Enter the following command to install the driver into /usr/src/linux/drivers/scsi/lpfc, the driver_installation_directory. # rpm -i filename.rpm 6. Enter the following command to install the driver into /usr/src/<kernelsource>/drivers/scsi/lpfc, the driver_installation_directory. # rpm -i --prefix /usr/src/<kernelsource>/drivers/scsi/lpfc filename.rpm If the prefix option is used you must update BASEINCLUDE in the Makefile placed in the installation directory. 7. Enter the following command to verify that the RPM installation was successful: # rpm -a -q | grep lpfc 8. Enter the following command to remove the RPM type: # rpm -e rpm_name 9. Enter the following command to change directory to driver_installation_directory. # cd /usr/src/<kernelsource>/drivers/scsi/lpfc 36 Host Bus Adapter for Windows and Linux Installation Guide
  • 37. Installing the SCSI Miniport Driver Building the Driver as a Module Once you have installed the source file, you can build the driver as a module. 1. At the shell prompt, edit lpfc.conf.c to reflect your desired configuration. 2. Enter the following command to verify that both kernel-headers and kernel-source RPMs are installed: # rpm -a -q | grep kernel 3. Enter the following command to install the kernel-headers and kernel-source RPMs if they are not installed: # rpm -i kernel-headers* # rpm -i kernel-source* Note: Red Hat Version 7.3 does not recognize kernel headers. Kernel headers is replaced by glibc_kernelheaders.rpm. By default, the driver looks for the kernel source under /usr/src/linux. If the source resides under a different directory, there are two ways to enable the driver to locate the kernel source. 4. Enter the following command if the kernel source resides in /usr/src/<kernelsource>: # ln -sf /usr/src/<kernelsource> /usr/src/linux A directory listing similar to the following displays: lrwxrwxrwx1rootroot11Aug 2 13:51 linux -> linux-2.4.4 drwxr-xr-x14 1046 101 4096Aug 2 13:51 linux-2.4.4 Or change the BASEINCLUDE variable in Makefile to point to the correct location. For example: BASEINCLUDE = /usr/src/kernelsource 5. Enter the following command to verify the kernel type (SMP or non-SMP): # uname -r 6. Only for non-SMP kernel module (i386 platform only), edit the Makefile and delete the following text: -D__SMP__=1 Host Bus Adapter for Windows and Linux Installation Guide 37
  • 38. Installing the SCSI Miniport Driver The edited text should now display as follows: # For 32-bit environment # If this is not a SMP environment remove the -D__SMP__=1 from CFLAGSCFLAGS = -D__KERNEL__=1 $[MODINC] $[INCLUDEDIR] 7. For SuSE Linux, enter the following ifconfig command (all on one line): # cp /boot/vmlinuz.version.h /lib/modules/'uname-r'/build/include/linux/version.h 8. Enter the following command to build the drivers: # make build This will create the driver files similar to the following: -rw-r--r-- 1 root root 226200 Aug 13 10:33 lpfcdd.2.4.4.o -rw-r--r-- 1 root root 3334 Aug 13 10:33 lpfndd.2.4.4.o 9. Enter the following command to install both drivers under /lib/modules/kernel_version: # make install 38 Host Bus Adapter for Windows and Linux Installation Guide
  • 39. Installing the SCSI Miniport Driver Loading the Driver There are two ways to load the driver: manually or through the RAM disk image. Loading the Driver Manually 1. Enter the following commands: # insmod lpfcdd # insmod lpfndd lpfcdd - main driver, SCSI functionality, FCP support, diagnostic support lpfndd - IP support (this driver is dependent on lpfcdd being loaded first) 2. Enter the following command to bring up the interface: Edit /etc/sysconfig/network-scripts/ifcfg-lpfnX. 3. On SuSE, run the ifconfig command (all on one line) to configure the interface: insmod lpfndd ifconfig lpfn X inet 172.16.0.1 netmask 255.255.255.0 broadcast 199.199.255.255 Where X is the interface number, 0 through 7. This file should be created if you wish to configure IP. An example of this file: DEVICE=lpfn0IPADDR=138.239.40.6 BROADCAST=138.239.40.255 NETWORK=138.239.40.0 NETMASK=255.255.255.0 ONBOOT=yes 4. Enter the following command to manually bring up the IP interface: ifup lpfnX Where X is the interface number, 0 through 7. 5. Enter the following commands if the system does not have a SCSI driver loaded: # insmod scsi_mod # insmod sd_mod Rebooting the system will unload the driver. You should include the above commands in a start up script to automatically load the driver. Host Bus Adapter for Windows and Linux Installation Guide 39
  • 40. Installing the SCSI Miniport Driver Loading the Driver Through the RAM Disk Image 1. To add SCSI and IP modules, edit /etc/conf.modules or modules.conf, depending on the Linux release. Add the following line to add a SCSI module: alias scsi_hostadapter lpfcdd Add the following line to add an IP module: alias lpfnX lpfndd where X is the interface number, 0 through 7. Note: If you want to configure SCSI only, just add the scsi_hostadapter line. The IP module is dependent on the SCSI modules being there, so you cannot configure just IP. 2. Run the following command to update your system with the information you added to /etc/conf.modules: # depmod -a Edit /etc/sysconfig/network-scripts/ifcfg-lpfnX. Where X is the interface number, 0 through 7. This file should be created if you wish to configure IP. An example of this file: DEVICE=lpfn0 IPADDR=138.239.40.6 BROADCAST=138.239.40.255 NETWORK=138.239.40.0 NETMASK=255.255.255.0 ONBOOT=yes SuSE does not use the above structure. 3. Run the following script (all on one line) once lpfcdd is loaded to bring up IP: insmod lpfndd ifconfig lpfxdd inet n.n.n.n. broadcast n.n.n.n netmaskn.n.n.n. Edit /etc/lilo.conf to specify boot / startup parameters. Keep a boot image record that is known to be good, so you can boot the system in case of problems. A boot image record consists of lines between “image=kernel_version” entries. An example of a default /etc/lilo.conf: boot=/dev/sda map=/boot/map install=/boot/boot.bprompt 40 Host Bus Adapter for Windows and Linux Installation Guide
  • 41. Installing the SCSI Miniport Driver timeout=50 default=linux image=/boot/vmlinuz-kernel_version label=linux root=/dev/sda8 initrd=/boot/initrd-kernel_version.imgread-only 4. Add the following lines to the end of the file to add a new boot record for the driver: image=/boot/vmlinuz-kernel_version label=new_label root=/dev/sda8 initrd=/boot/new_image_filenameread-only append=”max_scsi_luns=128” Note: Currently, lpfc is not supported as the root device, so keep the “root=/dev/xxx” parameter the same. 5. Add the following line to get multiple LUN support: append=”max_scsi_luns=LUNs” Where LUNs is the number of LUNs per SCSI device. Adding this line is optional. 6. Run these commands to build the boot image. The boot image new_image_name must match the name specified in the /etc/lilo.conf file: # rm -f /boot/new_image_filename # /sbin/mkinitrd /boot/new_image_filename kernel_version 7. Run these commands to check and load the boot image: # lilo -t -v # lilo -v 8. Reboot the system to incorporate the new driver. At the shell prompt, enter the following: # sync # reboot 9. As the system reboots, you are prompted with LILO boot. At this point enter the name of the label of your boot image, new_label in the above example, or just press enter and the default boot image will be loaded. Host Bus Adapter for Windows and Linux Installation Guide 41
  • 42. Installing the SCSI Miniport Driver Building the Driver Into the Kernel SCSI Functionality Once you have installed the source files, you can build the driver into the kernel. 1. Enter the following commands: # mkdir /usr/src/linus/scsi/lpfc # find . -print | cpio -pdumv /usr/src/linux/drivers/scsi/lpfc # cd /usr/src/linux/drivers/scsi/lpfc # cp Makefile.kernel Makefile 2. Edit the Makefile and the lpfc.conf.c files, if needed. 3. Enter the following command to change the directory to the Linux source: # cd /usr/src/linux/ 4. Edit Rules.make and remove “$(sort and the matching closing parenthesis from this line: subdir-list = $(sort $(patsubst %,_subdir_%,$(SUB_DIRS))) The edited line should now display as follows: subdir-list = $(patsubst %,_subdir_%,$(SUB_DIRS)) Note: For some 2.4 based kernels, this will allow the scsi/lpfc Makefile to be invoked BEFORE the scsi Makefile. 5. Edit the Makefile under the drivers directory: # cd /usr/src/linux/drivers # vi Makefile 6. Add a check for $(CONFIG_SCSI_LPFC) to add scsi/lpfc to the directory lists before $(CONFIG_SCSI) adds scsi to the directory lists. The scsi/lpfc Makefile should be invoked BEFORE the scsi Makefile. Edit the following lines: subdir-$(CONFIG_IDE) += ide subdir-$(CONFIG_SCSI) += scsi 7. Add the following line: subdir-$(CONFIG_SCSI_LPFC) += scsi/lpfc 42 Host Bus Adapter for Windows and Linux Installation Guide
  • 43. Installing the SCSI Miniport Driver The edited lines should now display as follows: subdir-$(CONFIG_IDE) += ide subdir-$(CONFIG_SCSI_LPFC) += scsi/lpfc subdir-$(CONFIG_SCSI) += scsi 8. Go to the scsi directory: # cd /usr/src/linux/drivers/scsi Edit Config.in and locate the following lines (the lines may wrap.): dep_tristate 'EATA-PIO [old DPT PM2001, PM2012A] support' CONFIG_SCSI_EATA_PIO $CONFIG_SCSI dep_tristate 'Future Domain 16xx sCSI/AHA-2920A support' CONFIG_SCSI_FUTURE_DOMAIN $CONFIG_SCSI 9. Add the following line (in alphabetical order): dep_tristate 'Emulex LightPulse Fibre Channel support' CONFIG_SCSI_LPFC $CONFIG_SCSI The edited lines should now display as follows. dep_tristate 'EATA-PIO [old DPT PM2001, PM2012A] support' CONFIG_SCSI_EATA_PIO $CONFIG_SCSI dep_tristate 'Emulex LightPulse Fibre Channel support' CONFIG_SCSI_LPFC $CONFIG_SCSI dep_tristate 'Future Domain 16xx sCSI/AHA-2920A support' CONFIG_SCSI_FUTURE_DOMAIN $CONFIG_SCSI 10. Edit Makefile and add (with other CONFIG_SCSI_devices) a check for $(CONFIG_SCSI_LPFC), if defined. Add lpfcdd.o to the object list. 11. Locate the following lines: obj-$(CONFIG_SCSI_IPS) += ips.o obj-$(CONFIG_SCSI_FD_MCS) += fd_mcs.o obj-$(CONFIG_SCSI_FUTURE_DOMAIN)+= fdomain.o 12. Add the following line: obj-$(CONFIG_SCSI_LPFC) += lpfcdd.o The edited lines should now display as follows. obj-$(CONFIG_SCSI_IPS) += ips.o obj-$(CONFIG_SCSI_LPFC) += lpfcdd.o obj-$(CONFIG_SCSI_FD_MCS) += fd_mcs.o obj-$(CONFIG_SCSI_FUTURE_DOMAIN)+= fdomain.o 13. For some 2.2 based kernels, edit hosts.c. Add the following lines: #ifdef CONFIG_SCSI_LPFC #include “lpfc/include/fc_os.h” #endif Host Bus Adapter for Windows and Linux Installation Guide 43
  • 44. Installing the SCSI Miniport Driver 14. At the end of the definition for Scsi_Host_Template, before “Removable host adapters”, add the following lines: #ifdef CONFIG_SCSI_LPFC EMULEXFC, #endif IP Functionality 1. Go to the net directory: # cd /usr/src/linux/drivers/net 2. Edit Config.in. Edit the following lines: bool 'Fibre Channel driver support' CONFIG_NET_FC if [“$CONFIG_NET_FC” = “y”]; then dep_tristate' Interphase 5526 Tachyon chipset based adapter support' CONFIG_IPHASE5526 $CONFIG_SCSI$CONFIG_PCI fi 3. Add the following line (all one line): dep_tristate ' Emulex LightPulse Fibre Channel support' CONFIG_NET_LPFC $CONFIG_SCSI $CONFIG_PCI The edited lines should now display as follows: bool 'Fibre Channel driver support' CONFIG_NET_FC if [“$CONFIG_NET_FC” = “y”]; then dep_tristate' Interphase 5526 Tachyon chipset based adapter support' CONFIG_IPHASE5526 $CONFIG_SCSI$CONFIG_PCIdep_tristate ' Emulex LightPulse Fibre Channel support' CONFIG_NET_LPFC $CONFIG_SCSI $CONFIG_PCI fi 4. Locate the following text in Space.c: #ifdef CONFIG_NET_FC static int fcif_probe(struct net_device *dev) { if (dev->base_addr == -1) return 1; if (1 #ifdef CONFIG_IPHASE5526 && iph5526_probe(dev) #endif && 1) { return 1; /* -ENODEV or -EAGAIN would be more accurate. */ } return 0; } #endif /* CONFIG_NET_FC */ 44 Host Bus Adapter for Windows and Linux Installation Guide
  • 45. Installing the SCSI Miniport Driver 5. Add this text after #ifdef CONFIG_NET_FC: static int lpfnif_probe(struct net_device *dev){ #ifdef CONFIG_LPFC_SCSI lpfn_probe(); #endif return 0; } The edited lines should now display as follows: #ifdef CONFIG_NET_FC static int lpfnif_probe(struct net_device *dev) { #ifdef CONFIG_LPFC_SCSI lpfn_probe(); #endif return 0; } static int fcif_probe(struct net_device *dev) { if (dev->base_addr == -1) return 1; if (1 #ifdef CONFIG_IPHASE5526 && iph5526_probe(dev) #endif && 1) { return 1; /* -ENODEV or -EAGAIN would be more accurate. */ } return 0; } #endif /* CONFIG_NET_FC */} 6. Locate the following lines: #ifdef CONFIG_NET_FC static struct net_device fc1_dev = { “fc1”, 0, 0, 0, 0, 0, 0, 0, 0, 0, NEXT_DEV, fcif_probe}; static struct net_device fc0_dev = { “fc0”, 0, 0, 0, 0, 0, 0, 0, 0, 0, &fc1_dev, fcif_probe}; # undef NEXT_DEV # define NEXT_DEV (&fc0_dev) #endif 7. Add these lines after: # define NEXT_DEV (&fc0_dev): static struct net_device lpfn_dev = { “lpfn”, 0, 0, 0, 0, 0, 0, 0, 0, 0, NEXT_DEV, lpfnif_probe}; # undef NEXT_DEV # define NEXT_DEV (&lpfn_dev) The edited lines display as follows: #ifdef CONFIG_NET_FC static struct net_device fc1_dev = { Host Bus Adapter for Windows and Linux Installation Guide 45
  • 46. Installing the SCSI Miniport Driver “fc1”, 0, 0, 0, 0, 0, 0, 0, 0, 0, NEXT_DEV, fcif_probe}; static struct net_device fc0_dev = { “fc0”, 0, 0, 0, 0, 0, 0, 0, 0, 0, &fc1_dev, fcif_probe}; # undef NEXT_DEV # define NEXT_DEV (&fc0_dev)static struct net_device lpfn_dev = { “lpfn”, 0, 0, 0, 0, 0, 0, 0, 0, 0, NEXT_DEV, lpfnif_probe}; # undef NEXT_DEV # define NEXT_DEV (&lpfn_dev) #endif 8. Follow the normal procedures for building the Linux kernel and include all Emulex LightPulse Fibre Channel support: # cd /usr/src/linux # make mrproper # make menuconfig 9. Choose 'Emulex LightPulse Fibre Channel support' under SCSI low level drivers for FCP support. 10. Choose “Fibre Channel driver support” “Emulex LightPulse Fibre Channel support” under Network Drive support for IP support. 11. Choose any other options that may be required. 12. Build the new kernel and modules: # make dep # make clean # make install # make modules # make modules_install 1. Edit lilo.conf to reflect the new kernel and run mkinitrd and lilo as explained in the procedure for Building the Driver as a Module. 2. Reboot with the new kernel. 46 Host Bus Adapter for Windows and Linux Installation Guide
  • 47. Installing the SCSI Miniport Driver Setting up and Running Diagnostic Utilities 1. Go to the driver source directory. # cd driver_installation_directory 2. Enter one of the following commands to run the diagnostic utilities: # ./lputil or # ./dfc Installing the Latest Version of HBA API and Utilities 1. Enter the following command to install the latest version of HBA API and utilities: # sh Install.sh Host Bus Adapter for Windows and Linux Installation Guide 47
  • 48. Installing the SCSI Miniport Driver 48 Host Bus Adapter for Windows and Linux Installation Guide
  • 49. Troubleshooting 4 4 Introduction The Power-On Self Test (POST) and the Windows Event Viewer are troubleshooting utilities you can use for the Host Bus Adapter (HBA). This chapter explains the use of these utilities in the event of an HBA problem. Host Bus Adapter for Windows and Linux Installation Guide 49
  • 50. Troubleshooting POST Conditions and Results Table 4 lists the HBA LED states with descriptions of each.The position of the POST LED indicators is defined in Figure 1 and Table 2 of this guide. If the LEDs indicate a failure during POST: 1. Make sure that the HBA is seated firmly in the PCI slot. 2. Verify that the fibre cable connection to the HBA is secure. Table 4: Normal POST LED Indicators Amber LED (L1) Green LED (L2) State Off Off Wake-up failure (dead board) On Off POST failure (dead board) Slow blink (1 Hz) Off Wake-up failure (dead board) Fast blink (4 Hz) Off Failure in POST (dead board) Flashing (irregular) Off POST processing in progress Off On Failure while functioning On On Failure while functioning Slow blink (1 Hz) On Normal—1 Gb link rate Fast blink (4 Hz) On Normal—2 Gb link rate Off Blink (1 Hz) Normal—link down or not yet started 50 Host Bus Adapter for Windows and Linux Installation Guide
  • 51. Troubleshooting Using The Event Viewer The Windows SCSI driver verifies the condition of the HBA POST. If there is a failure or a suspected failure, an error log entry is issued to the Windows Event log. Following is the procedure for viewing the event log. From the Main menu: 1. Double-click or choose the Administrative Tools program group. 2. Double-click or choose the Event Viewer. The display shows a list of discrete events specifying the source name: ■ For Windows NT, specify LPGNDS35 ■ For Windows 2000 or Windows Server 2003, specify CPQKGPSA. 3. Double-click any event with the source name. 4. Change the data view from Bytes (default) to Words. 5. Examine the entry at offset 0x10: if the low byte = En, match the low byte with the error found in Table 5, Windows NT SCSI Port Error Log. Table 6 and Table 7 list CmdStat values and Parameter error values. Host Bus Adapter for Windows and Linux Installation Guide 51
  • 52. Troubleshooting Windows Miniport Event Log Codes The Windows Miniport driver logs events and errors in the Windows Event log. Serious errors are always logged. Informational events are only logged if the registry parameter LogError=1 is used. All Miniport logged events are issued with an Event ID of 11 (INTERNAL ADAPTER ERROR) but do not necessarily indicate an HBA error occurred. Byte offset 0x10 of the event is the driver event code. Byte offsets 0x11 to 0x13 contain event-specific information. Table 5 describes the SCSI port error log codes Table 5: SCSI Port Error Log Codes 0x10 0x11 to 0x13 Further Offset Explanation Information 0xC0 Invalid Link Speed Selection (Windows NT) 0xD0 SNS_REQ (XMIT_SEQ failed) 0x11 = cmdstat, 12 = parm err 0xD1 SNS_RSP (RCV_SEQ failed) 0x11 = cmdstat, 12 = parm err 0xD3 RCV_ELS_REQ failed 0x11 = cmdstat, 12 = parm err 0xD4 XMT_ELS_REQ failed 0x11 = cmdstat, 12 = parm err 0xD5 Too many targets found (160+) 0x11 to 13 = D_DID that didn’t fit 0xD6 SNS request time-out 0x11 to 13 no additional information 0xD7 Mailbox interrupt time-out 0x11 = mailbox word 0 0xD8 TPRLO requested when busy 0x11 = local req. state, 12 = discstate, 13 = mailbox word 0 0xD9 Link down time-out occurred 0x11 = local req. state, 12 = discstate, 13 = mailbox word 0 0xDA Hard link down time-out 0x11 = local req. state, 12 = occurred discstate, 13 = mailbox word 0 0xE0 Node purged from configuration 0x11 to 0x13 = D_ID of node (Windows NT) purged 0xE1 Error interrupt occurred Status register bytes 1-3 in event 11-13. E1 error indicates an HBA hardware failure, return HBA for repair. 52 Host Bus Adapter for Windows and Linux Installation Guide
  • 53. Troubleshooting Table 5: SCSI Port Error Log Codes (Continued) 0x10 0x11 to 0x13 Further Offset Explanation Information 0xE2 Mailbox cmd time-out 0x11 = command 0xE3 Mailbox rsp err 0x11 = command, 12-13 = mbxstatus 0xE4 HBA not ready after init Status register bytes 1-3 in event 11-13 0xE5 Requested loop but link = PT-PT 0xE6 Mailbox int. but cmd not 0x11 = MB cmd, 12-13 = mbxstatus complete 0xE7 SRB already queued to ring 0xE8 RESTART failed 0xE9 PORT BYPASS (LPB) received 0xEB Unknown IOCB cmd rsp 0x11 = 15:8 = cmd field 0xEC Uncached extension alloc. Error 0xED Link down @ boot time (30 sec) 0xEF Too many interrupts at initial boot 0xF0 Rcv ELS request (possible logout) 0x11 = ELS type, 12-13 = X_ID (Windows NT) 0xF1 LinkUp error; LP8 down, driver 0x11 = parameter field, 12 = IOCB up cmd 0xF2 LinkUp w/ illegal or corrupt RPI 0x11 = parameter field, 12 = IOCB cmd 0xF3 DeQueue ring->iotcmd.head 0x11 = caller ID 0xF4 HBA reset 0x11 = coded reason for reset: Bit 0 = IOCB requeue; bit 1 = readla retry Bit 2 = initlink retry; bit 3 = rstbus retry Bit 4 = mailbox time-out 0xF5 PCP_IXXX_CR IOCB rsp err 0x11 = cmdstat, 12 = parm err, 13 = ALPA Host Bus Adapter for Windows and Linux Installation Guide 53
  • 54. Troubleshooting Table 5: SCSI Port Error Log Codes (Continued) 0x10 0x11 to 0x13 Further Offset Explanation Information 0xF6 PCP_IXXX_CR IOCB rsp err 0x11 = cmdstat, 12 = parm err, 13 = ALPA 0xF7 Ring hd !=0 && pendingsrb!=NULL 0xF8 Invalid FCP_RSP 0x11 = pcpcntrl, 12 = scsisat, 13 = len 0xF9 Two consec. time-outs, issue LIP 0xFA START_IO error 0x11 = errtype, 12 = srbstat, 13 = linkup 0xFB ELS_REQ_CR IOCB rsp err 0x11 = cmdstat, 12 = parm err, 13 = ALPA 0xFC ELS_REQ_CR IOCB rsp err 0x11 = cmdstat, 12 = parm err, 13 = ALPA 0xFE FLOGI failed 0x11 = cmdstat, 12 = parm err 0xFF SNS_PLOGI failed 0x11 = cmdstat, 12 = parm err Table 6: CmdStat Values 0x11 Offset Explanation Further Information 0x1 IOSTAT_FCP_RSP_ERR 0x2 IOSTAT_REMOTE_STOP Remote sent an ABTS 0x3 IOSTAT_LOCAL_REJECT Parameter field contains additional information 0x4 IOSTAT_NPORT_RJT 0x5 IOSTAT_FABRIC_RJT 0x6 IOSTAT_NPORT_BSY 0x7 IOSTAT_FBRIC_BSY 0x8 IOSTAT_INTERMED_RSP 0x9 IOSTAT_LS_RJT 0xA IOSTAT_BA_RJT 54 Host Bus Adapter for Windows and Linux Installation Guide
  • 55. Troubleshooting Table 7: Parameter Error Values Valid only when CmdStat=0x3 0x12 Offset Explanation 0x00 IOERR_SUCCESS 0x01 IOERR_MISSING_CONTINUE 0x02 IOERR_SEQUENCE_TIMEOUT 0x03 IOERR_INTERNAL_ERROR 0x04 IOERR_INVALID_RPI 0x05 IOERR_NO_XRI 0x06 IOERR_ILLEGAL_COMMAND 0x07 IOERR_XCHG_DROPPED 0x08 IOERR_ILLEGAL_FIELD 0x09 IOERR_BAC_CONTINUE 0x0A IOERR_TOO_MANY_BUFFERS 0x0B IOERR_RCV_BUFFER_WAITING 0x0C IOERR_NO_CONNECTION 0x0D IOERR_TX_DMA_FAILED 0x0E IOERR_RX_DMA_FAILED 0x0F IOERR_ILLEGAL_FRAME 0x10 IOERR_EXTRA_DATA 0x11 IOERR_NO_RESOURCES 0x12 IOERR_RESERVED 0x13 IOERR_ILLEGAL_LENGTH 0x14 IOERR_UNSUPPORTED_FEATURE 0x15 IOERR_ABORT_IN_PROGRESS 0x16 IOERR_ABORT_REQUESTED 0x17 IOERR_RECEIVE_BUFFER_TIMEOUT 0x18 IOERR_LOOP_OPEN_FAILURE 0x19 IOERR_RING_RESET 0x1A IOERR_LINK_DOWN 0x1B IOERR_CORRUPTED_DATA Host Bus Adapter for Windows and Linux Installation Guide 55
  • 56. Troubleshooting Table 7: Parameter Error Values Valid only when CmdStat=0x3 (Continued) 0x12 Offset Explanation (Continued) 0x1C IOERR_CORRUPTED_RPI 0x1D IOERR_OUT_OF_ORDER 0x1E IOERR_OUT_OF_ORDER_ACK 0x1F IOERR_DUPLICATE_FRAME 0x20 IOERR_INVALID_ACK 0x21 IOERR_BAD_40BIT_ADDRESS 0x1A IOERR_RESERVED 0x1B IOERR_RESERVED 0x1C IOERR_RESERVED 0x1D IOERR_ABORT_MULTI_REQUESTED 0x1E IOERR_RESERVED 0x1F IOERR_RESERVED 0x20 IOERR_LINK_BUFFER_SHORTAGE 0x21 IOERR_RCV_XRIBUF_WAITING 0x22 IOERR_RESERVED 0x23 IOERR_RESERVED 0x24 IOERR_RESERVED 0x25 IOERR_ABORT_MULTI_REQUESTED 0x26 IOERR_RESERVED 0x27 IOERR_RESERVED 0x28 IOERR_LINK_BUFFER_SHORTAGE 0x29 IOERR_RCV_XRIBUF_WAITING 56 Host Bus Adapter for Windows and Linux Installation Guide
  • 57. Troubleshooting SCSI Address Mapping The driver emulates six SCSI buses per HBA to map all 126 possible AL_PA to Target IDs. The first bus is a dummy bus used to delay the initial inquiry scan until after discovery completes. The 31 target IDs per bus are then mapped to either ascending or descending SEL_IDs (based on the ScanDown registry parameter). Note: The driver uses the first bus if the parameter MapBus0=1 is used. Fabric Device Mapping In a fabric (switched) environment, devices are initially created in the order that they are returned from the Simple Name Server (SNS). Once created (at boot), the devices continue to be tracked based on: –WWPN:HardAddress=0;MapNodeName=0 –NodeName:HardAddress=0;MapNodeName=1 –D_ID:HardAddress=1; (MapNodeName=don’t care) Private Loop Device Mapping for Windows Platforms In a private loop environment (FC-AL, no switch), devices are initially created based on a fixed address ordering. Once created (at boot), the devices continue to be tracked based on: –WWPN:HardAddress=0;MapNodeName=0 –NodeName:HardAddress=0;MapNodeName=1 –D_ID:HardAddress=1; (MapNodeName=don’t care) This section identifies the initial fixed mapping between the Windows NT bus/target/lun and a Fibre Channel native address (AL_PA/SEL_ID). There are two potential mappings based on a registry parameter [ScanDown=0 (driver default); use *, ScanDown=1;]. Host Bus Adapter for Windows and Linux Installation Guide 57
  • 58. Troubleshooting The index into Table 8 can be derived by: #define TARGETS_PER_BUS 32 i = (Srb->PathId > 0) ? Srb->PathId-1 : 0; //Bus 0 = dummy bus nodeInx = ((I * (TARGETS_PER_BUS-1)) + Srb->TargetId;w Table 8: Current Private Loop Device Mapping Target **AL_P Bus # # Lun# *AL_PA SEL_ID A SEL_ID 0 0-31 0-7 None None None None IMPORTANT: 0 0-7 0x01 0x7D 0xEF 0x00 * 1 0-7 0x02 0x7C 0xE8 0x01 2 0-7 0x04 0x7B 0xE4 0x02 3 0-7 0x08 0x7A 0xE2 0x03 4 0-7 0x0F 0x79 0xE1 0x04 5 0-7 0x10 0x78 0xE0 0x05 6 0-7 0x17 0x77 0xDC 0x06 7 0-7 0x18 0x76 0xDA 0x07 8 0-7 0x1B 0x75 0xD9 0x08 9 0-7 0x1D 0x74 0xD6 0x09 10 0-7 0x1E 0x73 0xD5 0x0A 11 0-7 0x1F 0x72 0xD4 0x0B 12 0-7 0x23 0x71 0xD3 0x0C 13 0-7 0x25 0x70 0xD2 0x0D 14 0-7 0x26 0x6F 0xD1 0x0E 15 0-7 0x27 0x6E 0xCE 0x0F 16 0-7 0x29 0x6D 0xCD 0x10 17 0-7 0x2A 0x6C 0xCC 0x11 18 0-7 0x2B 0x6B 0xCB 0x12 19 0-7 0x2C 0x6A 0xCA 0x13 20 0-7 0x2D 0x69 0xC9 0x14 *Use this translation if registry ScanDown = 0 (default). **Use this translation if registry ScanDown = 1. ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1. 58 Host Bus Adapter for Windows and Linux Installation Guide
  • 59. Troubleshooting Table 8: Current Private Loop Device Mapping (Continued) Target **AL_P Bus # # Lun# *AL_PA SEL_ID A SEL_ID 0 0-31 0-7 None None None None 21 0-7 0x2E 0x68 0xC7 0x15 22 0-7 0x31 0x67 0xC6 0x16 23 0-7 0x32 0x66 0xC5 0x17 24 0-7 0x33 0x65 0xC3 0x18 25 0-7 0x34 0x64 0xBC 0x19 26 0-7 0x35 0x63 0xBA 0x1A 27 0-7 0x36 0x62 0xB9 0x1B 28 0-7 0x37 0x61 0xB6 0x1C 29 0-7 0x3A 0x60 0xB5 0x1D 30 0-7 0x3C 0x5F 0xB4 0x1E 31 0-7 None None None None IMPORTANT: 0 0-7 0x43 0x5E 0xB3 0x1F *** 1 0-7 0x45 0x5D 0xB2 0x20 2 0-7 0x46 0x5C 0xB1 0x21 3 0-7 0x47 0x5B 0xAE 0x22 4 0-7 0x49 0x5A 0xAD 0x23 5 0-7 0x4A 0x59 0xAC 0x24 6 0-7 0x4B 0x58 0xAB 0x25 7 0-7 0x4C 0x57 0xAA 0x26 8 0-7 0x4D 0x56 0xA9 0x27 9 0-7 0x4E 0x55 0xA7 0x28 10 0-7 0x51 0x54 0xA6 0x29 11 0-7 0x52 0x53 0xA5 0x2A 12 0-7 0x53 0x52 0xA3 0x2B 13 0-7 0x54 0x51 0x9F 0x2C *Use this translation if registry ScanDown = 0 (default). **Use this translation if registry ScanDown = 1. ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1. Host Bus Adapter for Windows and Linux Installation Guide 59
  • 60. Troubleshooting Table 8: Current Private Loop Device Mapping (Continued) Target **AL_P Bus # # Lun# *AL_PA SEL_ID A SEL_ID 0 0-31 0-7 None None None None 14 0-7 0x55 0x50 0x9E 0x2D 15 0-7 0x56 0x4F 0x9D 0x2E 16 0-7 0x59 0x4E 0x9B 0x2F 17 0-7 0x5A 0x4D 0x98 0x30 18 0-7 0x5C 0x4C 0x97 0x31 19 0-7 0x63 0x4B 0x90 0x32 20 0-7 0x65 0x4A 0x8F 0x33 21 0-7 0x66 0x49 0x88 0x34 22 0-7 0x67 0x48 0x84 0x35 23 0-7 0x69 0x47 0x82 0x36 24 0-7 0x6A 0x46 0x81 0x37 25 0-7 0x6B 0x45 0x80 0x38 26 0-7 0x6C 0x44 0x7C 0x39 27 0-7 0x6D 0x43 0x7A 0x3A 28 0-7 0x6E 0x42 0x79 0x3B 29 0-7 0x71 0x41 0x76 0x3C 30 0-7 0x72 0x40 0x75 0x3D 31 0-7 None None None None IMPORTANT: 0 0-7 0x73 0x3F 0x74 0x3E *** 1 0-7 0x74 0x3E 0x73 0x3F 2 0-7 0x75 0x3D 0x72 0x40 3 0-7 0x76 0x3C 0x71 0x41 4 0-7 0x79 0x3B 0x6E 0x42 5 0-7 0x7A 0x3A 0x6D 0x43 6 0-7 0x7C 0x39 0x6C 0x44 *Use this translation if registry ScanDown = 0 (default). **Use this translation if registry ScanDown = 1. ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1. 60 Host Bus Adapter for Windows and Linux Installation Guide
  • 61. Troubleshooting Table 8: Current Private Loop Device Mapping (Continued) Target **AL_P Bus # # Lun# *AL_PA SEL_ID A SEL_ID 0 0-31 0-7 None None None None 7 0-7 0x80 0x38 0x6B 0x45 8 0-7 0x81 0x37 0x6A 0x46 9 0-7 0x82 0x36 0x69 0x47 10 0-7 0x84 0x35 0x67 0x48 11 0-7 0x88 0x34 0x66 0x49 12 0-7 0x8F 0x33 0x65 0x4A 13 0-7 0x90 0x32 0x63 0x4B 14 0-7 0x97 0x31 0x5C 0x4C 15 0-7 0x98 0x30 0x5A 0x4D 16 0-7 0x9B 0x2F 0x59 0x4E 17 0-7 0x9D 0x2E 0x56 0x4F 18 0-7 0x9E 0x2D 0x55 0x50 19 0-7 0x9F 0x2C 0x54 0x51 20 0-7 0xA3 0x2B 0x53 0x52 21 0-7 0xA5 0x2A 0x52 0x53 22 0-7 0xA6 0x29 0x51 0x54 23 0-7 0xA7 0x28 0x4E 0x55 24 0-7 0xA9 0x27 0x4D 0x56 25 0-7 0xAA 0x26 0x4C 0x57 26 0-7 0xAB 0x25 0x4B 0x58 27 0-7 0xAC 0x24 0x4A 0x59 28 0-7 0xAD 0x23 0x49 0x5A 29 0-7 0xAE 0x22 0x47 0x5B 30 0-7 0xB1 0x21 0x46 0x5C 31 0-7 None None None None *Use this translation if registry ScanDown = 0 (default). **Use this translation if registry ScanDown = 1. ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1. Host Bus Adapter for Windows and Linux Installation Guide 61
  • 62. Troubleshooting Table 8: Current Private Loop Device Mapping (Continued) Target **AL_P Bus # # Lun# *AL_PA SEL_ID A SEL_ID 0 0-31 0-7 None None None None IMPORTANT: 0 0-7 0xB2 0x20 0x45 0x5D *** 1 0-7 0xB3 0x1F 0x43 0x5E 2 0-7 0xB4 0x1E 0x3C 0x5F 3 0-7 0xB5 0x1D 0x3A 0x60 4 0-7 0xB6 0x1C 0x39 0x61 5 0-7 0xB9 0x1B 0x36 0x62 6 0-7 0xBA 0x1A 0x35 0x63 7 0-7 0xBC 0x19 0x34 0x64 8 0-7 0xC3 0x18 0x33 0x65 9 0-7 0xC5 0x17 0x32 0x66 10 0-7 0xC6 0x16 0x31 0x67 11 0-7 0xC7 0x15 0x2E 0x68 12 0-7 0xC9 0x14 0x2D 0x69 13 0-7 0xCA 0x13 0x2C 0x6A 14 0-7 0xCB 0x12 0x2B 0x6B 15 0-7 0xCC 0x11 0x2A 0x6C 16 0-7 0xCD 0x10 0x29 0x6D 17 0-7 0xCE 0x0F 0x27 0x6E 18 0-7 0xD1 0x0E 0x26 0x6F 19 0-7 0xD2 0x0D 0x25 0x70 20 0-7 0xD3 0x0C 0x23 0x71 21 0-7 0xD4 0x0B 0x1F 0x72 22 0-7 0xD5 0x0A 0x1E 0x73 23 0-7 0xD6 0x09 0x1D 0x74 24 0-7 0xD9 0x08 0x1B 0x75 *Use this translation if registry ScanDown = 0 (default). **Use this translation if registry ScanDown = 1. ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1. 62 Host Bus Adapter for Windows and Linux Installation Guide
  • 63. Troubleshooting Table 8: Current Private Loop Device Mapping (Continued) Target **AL_P Bus # # Lun# *AL_PA SEL_ID A SEL_ID 0 0-31 0-7 None None None None 25 0-7 0xDA 0x07 0x18 0x76 26 0-7 0xDC 0x06 0x17 0x77 27 0-7 0xE0 0x05 0x10 0x78 28 0-7 0xE1 0x04 0x0F 0x79 29 0-7 0xE2 0x03 0x08 0x7A 30 0-7 0xE4 0x02 0x04 0x7B 31 0-7 None None None None IMPORTANT: 0 0-7 0xE8 0x01 0x02 0x7C *** 1 0-7 0xEF 0x00 0x01 0x7D 2 0-7 None None None None 3 0-7 None None None None 4 0-7 None None None None 5 0-7 None None None None 6 0-7 None None None None 7 0-7 None None None None 8 0-7 None None None None 9 0-7 None None None None 10 0-7 None None None None 11 0-7 None None None None 12 0-7 None None None None 13 0-7 None None None None 14 0-7 None None None None 15 0-7 None None None None 16 0-7 None None None None 17 0-7 None None None None *Use this translation if registry ScanDown = 0 (default). **Use this translation if registry ScanDown = 1. ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1. Host Bus Adapter for Windows and Linux Installation Guide 63
  • 64. Troubleshooting Table 8: Current Private Loop Device Mapping (Continued) Target **AL_P Bus # # Lun# *AL_PA SEL_ID A SEL_ID 0 0-31 0-7 None None None None 18 0-7 None None None None 19 0-7 None None None None 20 0-7 None None None None 21 0-7 None None None None 22 0-7 None None None None 23 0-7 None None None None 24 0-7 None None None None 25 0-7 None None None None 26 0-7 None None None None 27 0-7 None None None None 28 0-7 None None None None 29 0-7 None None None None 30 0-7 None None None None 31 0-7 None None None None *Use this translation if registry ScanDown = 0 (default). **Use this translation if registry ScanDown = 1. ***If MapBus0= 1; then the device addressing starts with Bus#0, not Bus#1. 64 Host Bus Adapter for Windows and Linux Installation Guide
  • 65. Diagnostic and Configuration Utilities 5 5 This chapter contains instructions for installing and using the following Windows NT and Windows 2000 utilities: ■ DOS Diagnostic utility, x86DNLD, a DOS-based diagnostic and firmware download utility. This utility is used exclusively in standalone environments. ■ LightPulse Utility/NT, LP6DUTIL is a Windows-based graphical user interface for updating firmware and Boot code. This utility is used in Software Solution kits. Note: The diagnostic and firmware download utility is used to upgrade firmware on both Host Bus Adapter (HBA) environments. Host Bus Adapter for Windows and Linux Installation Guide 65
  • 66. Diagnostic and Configuration Utilities The DOS Diagnostic Utility The supplied software kit contains the DOS Diagnostic and firmware download utility. Functionally, the utility program performs: ■ Discovery and preliminary testing of the HBA in the system. ■ Functional testing and operational checks on the HBA. ■ The use of input and output files for automating the use of the diagnostic utility program. ■ Updating HBA firmware. Note: The diagnostic utility does not operate in the DOS shell under Windows. Installing the DOS Diagnostic Utility You must load the software and start the diagnostic utility from the DOS command line. You can run the program directly from the supplied software kit or you can load onto your hard drive and run it from there. Note: The diagnostic utility does not operate in the DOS shell under Windows. To install the utility onto the hard drive: 1. Insert the supplied diskette into your system’s diskette drive. 2. Make a directory and copy the files onto your hard drive, as follows: C:MD_DIRNAME C:COPY A:i386*.*C:DIR_NAME C:CD DIR_NAME DIR_NAME is the directory where the you install the diagnostic software. Starting the DOS Diagnostic Utility To start the program without any options, enter: X86DNLD.EXE 66 Host Bus Adapter for Windows and Linux Installation Guide
  • 67. Diagnostic and Configuration Utilities The options for X86DNLD are listed in Table 9. The syntax for using options is: A:X86DNLD.EXE {I = infilename} {o = outfilename} The following example shows a sample command: C: X86DNLD.EXE o = PCIHA001 PCIHA001 is the output filename. Table 9: DOS Diagnostic Utility Command Options Option Description Infilename Script input file that is read and executed by the program. Outfilename Creates a file of keystrokes that is stored for later use (for example, as an input file). Note: All message lines except user input begin with a number symbol (#) to indicate a comment line. Data entered by the user appears on a line by itself, not preceded by a #. Using the DOS Diagnostic Utility for Preliminary Testing The diagnostic program performs preliminary analysis of the HBA before displaying the main menu. If no HBA is found, the program exits. Error messages are displayed on failure conditions. During startup, the diagnostic and firmware download utility program: 1. Looks for installed PCI HBAs. 2. Executes preliminary testing on all installed HBAs. Tests include: a. SLIM memory test b. BIU register test c. BIU configuration registers test 3. Reports pass or fail status messages. 4. Resets the HBAs. 5. Checks Power-On Self Test (POST) status of HBAs. 6. Reports revision levels of diagnostic and functional firmware. 7. Displays the resources of each HBA. Host Bus Adapter for Windows and Linux Installation Guide 67
  • 68. Diagnostic and Configuration Utilities The following is a sample output of the DOS Diagnostic Utility Start-Up Procedure. ************************************************************* ** WARNING: This utility may not work with the Expanded Memory Manager (EMM386). Please read LP6DUTIL documentation for further details. ************************************************************* ** LP6000 Host Adapters found in the system: 1 PRELIMINARY TESTING of Host Adapter 1 Host Adapter 1: PASS 0xA: SLIM Memory Tests Host Adapter 1: PASS 0xA: BIU Registers Tests Host Adapter 1: PASS 0xA: BIU Configuration Registers Tests Adapter 1 PASSED PRELIMINARY TESTS Resetting Host Adapter 1 Host Adapter 1: POST Done. Host Adapter 1 is READY. Functional Firmware Loaded. Diagnostic Firmware Version x.x Functional Firmware Version x.x Hit RETURN or ENTER key to continue HOST ADAPTER 1 Resources Info pci_bus_num = 0 pci_dev_num = 0xA0 slim_base_adr = 0x000D0000 reg_mem_base_adr = 0x000D1000 reg_io_base_adr = 0x0000FC00 IRQ = 0xB 68 Host Bus Adapter for Windows and Linux Installation Guide
  • 69. Diagnostic and Configuration Utilities NOTE: Enter 0 in 'Option:' prompt to display previous menu NOTE: All values entered are hexadecimal LP6DUTIL Main Menu Revision x.x 1 - Test Host Adapters 2 - Modify Test Options 3 - Restart Host Adapters 4 - Input/Output 5 - Maintenance 6 - Show Host Adapters Info 7 - Quit Option: DOS Diagnostic Utility Main Menu After the diagnostic and firmware download utility goes through its start-up procedure, the Main menu displays and handles user requests. If the program detects two or more HBAs in the system, you are prompted to choose which HBAs is to be tested. Table 9 lists the function of each option on the Main menu. Table 10: DOS Diagnosis Utility Main Menu Selections Menu Selection Description 1 – Test Host Adapters Runs host-based internal and external loopback tests. 2 – Modify Test Options Enables you to disable or enable up to seven different tests, depending upon the cards installed (BIU-1 or BIU-2). Specify number of retries and actions to take if error occurs. 3 – Restart Host Adapters Resets the HBA. 4 – Input/Output Opens or closes input and output files. Host Bus Adapter for Windows and Linux Installation Guide 69
  • 70. Diagnostic and Configuration Utilities Table 10: DOS Diagnosis Utility Main Menu Selections 5 – Maintenance Updates firmware or non-volatile parameters in FLASH ROM. Displays program images stored in memory. 6 – Show Host Adapters Displays configuration and status data used by HP Info Technical Support. 7 – Quit Exits the program. Note: Enter zero (0) at the Option prompt to display the previous menu. All values are in reported hexadecimal. The menu options and descriptions are described in the following sections. 70 Host Bus Adapter for Windows and Linux Installation Guide
  • 71. Diagnostic and Configuration Utilities LightPulse Utility/NT Utility The LightPulse Utility/NT utility (lputilnt and lputil64) is a Host Bus Adapter (HBA) monitoring and management utility that lets you: ■ View HBA parameters ■ Modify driver parameters in the Windows registry These parameters have been set by the Original Equipment Manufacturer (OEM) setup file provided in the software kit. The Fibre Channel setup file, run as part of the platform kit configuration, will also modify them. The resulting parameter setting has been modified to provide the optimal setting for the supported configurations. The features and commands for the configuration utility for Windows Server 2003 (LPutil64.exe) are similar to those of the Windows NT and Windows 2000 configuration utility (lputilnt.exe). These differences will be pointed out in this document where appropriate. You can run the utility from the CD or copy and run it from your local hard drive. Note: You must install and connect the SCSI Miniport driver to at least one drive before LightPulse Utility/NT can operate properly. You can alternately set the registry parameter Simulate Device= to 1. View HBA Parameters From the LightPulse Utility/NT Main menu screen: 1. Choose an HBA. On the menu bar, click on an HBA or pull down the category list. 2. Choose an option to view HBA parameters. There are nine options available, each displaying a different group of HBA parameters: ■ Adapter Revision Levels—View information about the chipset and firmware revision levels of the selected HBA. ■ Firmware Maintenance—Maintain firmware revision levels of the selected HBA. ■ Loop Map—View a list of the members of the selected HBA loop map. Host Bus Adapter for Windows and Linux Installation Guide 71
  • 72. Diagnostic and Configuration Utilities ■ PCI Registers—Maintain the values of the PCI configuration registers of the selected HBA. ■ Configuration Data—Maintain information about the data in each of the configuration regions in the flash ROM of the selected HBA. ■ Driver Parameters—Maintain information about device driver parameters that are maintained in the Windows/NT registry. ■ Persistent Bindings—Maintain information about persistent bindings of the selected HBA. ■ Link Statistics—Maintain statistics about the arbitrated loop of the selected HBA. ■ Status and Counters—Maintain status and counters for bytes, frames, sequences, exchanges, and so on. Maintaining HBA Firmware Revision Levels 1. Choose the desired HBA. 2. Expand the category list and choose Firmware Maintenance. 3. Click Download. 4. Locate the new upgrade file. 5. Click Open. Note: The new software is transferred to the HBA. 6. Expand the category list and choose Adapter Revision Levels. 7. Verify that the new firmware revision is shown. Modify Diagnostic Driver Parameters in the Windows Registry This screen provides information about device driver parameters that are maintained in the Windows registry and allows you to modify those values. 72 Host Bus Adapter for Windows and Linux Installation Guide
  • 73. Diagnostic and Configuration Utilities Caution: Do not modify the registry parameters unless specifically instructed to do so by support personnel. Modifying registry parameters can result in an unstable SAN. The data display lists all available device driver parameters, along with the current, minimum, maximum, and default values. Parameters that have their value specified in the system registry are denoted with either a G or an L in the left-most column of the screen. The G indicates that the value is set in the global registry entry, which applies to all HBAs that do not have a local registry entry. The L indicates that the value is set in a registry entry specific to the selected HBA, which overrides the value settings in the global entry. Modify the Driver Parameters From the LightPulse Utility/NT Main menu screen: 1. Choose the desired HBA. 2. Expand the category list and choose Driver Parameters. 3. Double-click a Parameter Name. 4. Enter the desired value in the New Value field. 5. Choose the Permanent or Global checkbox: ■ Choose Permanent to cause the new value to be written to the system registry. If Permanent is not selected, the parameter reverts to its default value when the driver is reset. ■ Choose Global to change the global registry entry. Otherwise, the change is made to the HBA-specific registry entry. Table 11 lists the current parameters that you can set. Table 11: Driver Parameters Parameter Description AbortStatus = 0xn Values from 0x00 – 0xFF. Controls NT SRB error status for general Abort conditions. Default = SRB_STATUS_BUS_RESET (0x0E) which will not cause the current NT class driver to throttle down I/O performance after four of these errors have been received (on a per-LUN basis) ALTOV = n Values are in milliseconds from 1 to 15. Default = 15. Host Bus Adapter for Windows and Linux Installation Guide 73
  • 74. Diagnostic and Configuration Utilities Table 11: Driver Parameters (Continued) ARBTOV = n Values are milliseconds form 500 to 10000. Default = 1000. Represents FC_AL arbitration time-out prior to LIP. Class = n Values from 0-2. Default = 2. Controls which Fibre Channel Class will be used: 0 = Class 1, 1 = Class 2, 2 = Class 3. EDTOV = n Values are in milliseconds form 500 to 10000. Default = 1000. Represents error detect time-out value prior to LIP. EnableDPC = n Values 0 or 1. Default = 0. 0 = process I/O completion at interrupt level, 1 = process at DPC level. FrameSizeMSB = n Values from 1-8. Default = 8. Controls the upper byte of the receive FrameSize if issued in PLOGI. This lets the FrameSize to be constrained on 256 byte increments from 256 (1) – 2048 (8). HardALPA = 0xn Values from 0x01 – 0xEF. Default = 0x01 lets the HBA use a hard assigned loop address. NOTE: Only valid ALPAs can be used (see Table 6-2). LinkTimeOut = n Values are in seconds from 1 – 500. Default = 60. Controls the time-out at which link no longer busy requests but issues SELECTION_TIMEOUT error status. LogErrors = n Values 0 or 1. Default = 0. 0 = don’t log general HBA/drive errors. 1 = use Event Log to general errors. NodeTimeOut = n Values are in seconds from 1–255. Default = 10. Controls the time-out at which a formerly logged-in node will issue SELECTION_TIMEOUT error status to an I/O request. QueueDepth = n Values from 1–64 (decimal). Default = 64. Requests per LUN/Target (see Queue Target parameter). QueueTarget = n Vaules 0 or 1 (decimal). Default = 0. 0 = QueueDepth applies on a per LUN basis: 1 = QueueDepth applies on a Target basis. RATOV = n Values are in seconds from 2 to 120. Default = 2. This value is the ELS request time-out. ReadCheck = n Values 0 or 1. Default = 1. 0 = do not enable byte counting for read operations. 1 = enable byte counting. If bytes counted are less than requested transfer count, issue underrun. 74 Host Bus Adapter for Windows and Linux Installation Guide
  • 75. Diagnostic and Configuration Utilities Table 11: Driver Parameters (Continued) ResetFF = n Values 0 or 1. Default = 1. 0 = ResetBus translates to LIP (F7). 1 = ResetBus translates to LIP (FF). Used for WolfPack to force reservations to be freed when ResetBus issued. Only meaningful for FC_AL topology and Seagate native FC hard drives. ResetTPRLO = n Values 0 or 1. Default = 1. 0 = ResetBus translates to LIP (). 1 = ResetBus translates to ThirdPartyProcessLogout + LIP (). Used for WolfPack to force reservations to be freed when ResetBus is issued. RetryInterval = n Values are in seconds from 2-255. Default = 45. Used for time-out interval if RetryloTimeOut = 1. Must be shorter than Class driver TimeOutInterval. RetryloTimeOut = n Vaules 0 or 1. Default = 1. 1 = lets an HBA to time-out I/O prior to port driver’s time-out which causes a LIP/Link Reset. RTTOV = n Values are in milliseconds from 100 to 511. Default = 256. Represents time-out between phases of Off-line to On-line protocol. ScanDown = n Values 0 or 1. Default = 0. 0 = Lowest AL_PA = Lowest physical disk (ascending AL_PA order). 1 = Highest AL_PA = Lowest Physical Disk (ascending SEL_ID order). SilFlags = n Values from 0-2. Default = 0. Controls which driver interface to use. 0 = automode; attempt SLI-2 first. If that fails, uses SLI-1. 1 = always use SLI-1. 2 = always use SLI-2. SimulateDevice = n Values 0 or 1. Default = 0. 0 = do not create a “dummy” disk device. 1 = create a dummy disk to force the driver to load even if no disk devices are present at boot time. SnsALL = n Values 0 or 1. Default = 1. Controls which N_Ports are queried from the NameServer. 0 = SCSI FCP only. 1 = All N_Ports. Topology = n Values 0 or 1. Default = 0. 0 = FC_AL (loop), 1 = PT-PT Fabric. When set to 1, FLOGI, SCR/RSCN and NameServer queries are employed. TrafficCop = n Values 0 or 1. Default = 0. 1 = enable FC-AL loop master to run unfair and break potential arbitration problems by sending frames to itself. 0 = run fair all the time. Host Bus Adapter for Windows and Linux Installation Guide 75
  • 76. Diagnostic and Configuration Utilities Table 12 lists the Arbitrated Loop Physical Addresses you can set. Table 12: AL-PA Addresses 0x01 0x02 0x04 0x08 0x0F 0x10 0x17 0x18 0x1B 0x1D 0x1E 0x1F 0x23 0x25 0x26 0x27 0x29 0x2A 0x2B 0x2C 0x2D 0x2E 0x31 0x32 0x33 0x34 0x35 0x36 0x39 0x3A 0x3C 0x43 0x45 0x46 0x47 0x49 0x4A 0x4b 0x4C 0x4D 0x4D 0x51 0x52 0x53 0x54 0x55 0x56 0x59 0x5A 0x5C 0x63 0x65 0x66 0x67 0x69 0x6A 0x6B 0x6C 0x6D 0x6E 0x71 0x72 0x73 0x74 0x75 0x75 0x79 0x7A 0x7C 0x80 0x81 0x82 0x84 0x88 0x8F 0x90 0x97 0x98 0x9B 0x9D 0x9E 0x9F 0xA3 0xA5 0xA6 0xA7 0xA9 0xAA 0xAB 0xAC 0xAD 0xAE 0xB1 0xB2 0xB3 0xB4 0xB5 0xB6 0xB9 0xBA 0xBC 0xC3 0xC5 0xC6 0xC7 0xC9 0xCA 0xCB 0xCC 0xCD 0xCE 0xD1 0xD2 0xD3 0xD4 0xD5 0xD5 0xD9 0xDA 0xDC 0xE0 0xE1 0xE2 0xE4 0xE8 0xEF Test Host Bus Adapters (For lputilnt Only) Choose this option to run host-based internal and external loopback tests on the HBAs. From the LightPulse Utility/NT Main menu screen: 1. Choose Test Host Bus Adapters. 2. Enable or disable the external loopback tests: a. Enable the external loopback tests by selecting 1=Y. The default is disabled, 0=No. Internal BIU PCI loopback and other loopback tests are run automatically. b. Choose 0=No if you do not have an external loopback connector. Note: Testing the HBA while it is connected to an arbitrated loop is not recommended. 76 Host Bus Adapter for Windows and Linux Installation Guide
  • 77. Diagnostic and Configuration Utilities Modify Test Options (For lputilnt Only) Use this option to specify the number of passes on one or more of these tests: PCI loopback, internal loopback, external Loopback, or all three. From the LightPulse Utility/NT Main menu screen: 1. Choose Test. 2. Choose the following data for the PCI loopback, Internal loopback, External Loopback tests: a. The number of passes. The default is 0x50. 0=infinity b. The action to take upon encountering errors. Choose one of the following: — 0 = stop (default) — 1 = repeat — 2 = ignore Reset Host Bus Adapters Choose this option to reset the HBA. When a reset HBA occurs, the HBA performs POST testing and reloads functional firmware. Input/Output Choose this option to open or close input and output files. The contents of the Input file are interpreted and executed by the program. The output file contains a log of all messages. Note that nesting of input files is not supported. Show Host Bus Adapter Info (For lputilnt Only) Choose this option to display HBA data in these areas: ■ BIU PCI Configuration Parameters ■ Host Bus Adapter Info and Status ■ Adapter Revisions ■ Display Configuration Data ■ Service Parameters ■ Status/Counters Info ■ Link Status Host Bus Adapter for Windows and Linux Installation Guide 77
  • 78. Diagnostic and Configuration Utilities ■ Link Attention Quit the LightPulse Utility/NT Utility Choose this option to exit the program. A warning message indicates if any errors were encountered during the session. 78 Host Bus Adapter for Windows and Linux Installation Guide
  • 79. Regulatory Compliance Notices A A FCC Compliance Information Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Shielded cables must be used between this equipment and attached peripheral devices. The reader is cautioned that changes or modifications made to the equipment not expressly approved could void the user's authority to operate this equipment. Hewlett-Packard Company 3000 Hanover Street Palo Alto, CA 94304-1185 Or call 1-650-857-1501. (For continuous quality improvement, calls may be recorded or monitored.) To identify the device, refer to the part, series or model number found on the product. Host Bus Adapter for Windows and Linux Installation Guide 79
  • 80. Regulatory Compliance Notices The above statement applies to products marketed in the USA. Japanese Notice Canadian Notice This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Avis Canadien Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. 80 Host Bus Adapter for Windows and Linux Installation Guide
  • 81. Regulatory Compliance Notices Federal Communications Commission Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Any modifications to this device - unless expressly approved by the manufacturer - can void the user’s authority to operate this equipment under part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference and (2) This device must accept any interference that may cause undesirable operation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: ■ Reorient or relocate the receiving antenna. ■ Increase the separation between the equipment and receiver. ■ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ■ Consult the dealer or an experienced radio/TV technician for help. Note: Additional information on the need to interconnect the device with shielded (data) cables or the need for special devices, such as ferrite beads on cables, is required if such means of interference suppression was used in the qualification test for the device. This information will vary from device to device and needs to be obtained from the EMC group or product manager. Host Bus Adapter for Windows and Linux Installation Guide 81
  • 82. Regulatory Compliance Notices Japanese Notice Canadian Notice This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. Avis Canadien Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. 82 Host Bus Adapter for Windows and Linux Installation Guide
  • 83. glossary Glossary This glossary defines terms used in this guide or related to this product and is not a comprehensive glossary of computer terms. Glossary AL-PA Arbitrated Loop Physical Address. The address of a Fibre Channel node in an arbitrated loop. Arbitration The process of selecting one respondent from a collection of several candidates that request service at the same time. b/s (or bps) Bits per second. The number of energy pulses passing a given point in a transmission medium in one second; raw transmission speed before encoding. Bandwidth A measure of the information-carrying capacity of an optical fiber, normalized to a unit of MHz/km. This term is used to specify capacity of multi-mode fibers only. (For single-mode fibers, use dispersion). The difference between the highest and lowest frequencies in a specific range of frequencies. Baud A unit of signaling speed equal to the number of signal intervals per second, which might or might not be equal to the data rate in bits per second. The encoded bit rate per second. BIOS Basic Input/Output system. Software coded into the computer chips to accomplish various tasks. Boot BIOS Software coded into the chips on the HBA. A special program used to boot and control the computer. Broadband In data transmission, it denotes transmission facilities capable of handling frequencies greater than those required for high-grade voice communications. The higher frequency allows the carrying of several simultaneous channels. Host Bus Adapter for Windows and Linux Installation Guide 83
  • 84. Glossary Cladding The dielectric material surrounding the core of an electrical fiber or material surrounding the core of a fiber optic cable. It usually refers to diameter, often 125 m, measured in microns. Connector A mechanical device used to align and join two fibers together to provide a means for attaching and decoupling it to a transmitter, receiver, or another fiber. Core The central region of an optical fiber through which light is transmitted. Custom Device Module (CDM) A CDM is the driver component in the NetWare Peripheral Architecture used to drive specific storage devices attached to the HBA. See also NetWare Peripheral Architecture. Data Rate The maximum number of bits of information that can be transmitted per second in a data transmission link. It is typically expressed as Megabits per second (Mbps). Device Driver A software program that enables a personal computer to communicate with hard drives, CD-ROM drives, printers, and other peripherals. Device drivers are stored on a hard drive and are loaded into memory at boot up. Duplex Cable A two-fiber cable suitable for duplex transmission or transmissions in two directions. Duplex Transmission Transmission in both directions, either one direction at a time (half duplex) or both directions simultaneously (full duplex). Fabric A Fibre Channel interconnection method that allows multiple simultaneous and concurrent data transfers between multiple hosts and/or storage devices connected with a multi-port hub. FC-AL Abbreviation for Fibre Channel Arbitrated Loop, an interconnection scheme that supports from 1 to 126 ports on a loop in a shared medium topology. FCP Fibre Channel Protocol. FDDI Fibre Distributed Data Interface. A network based on the use of optical-fiber cable to transmit data at 100Mbit/sec. 84 Host Bus Adapter for Windows and Linux Installation Guide
  • 85. Glossary Fiber Thin filament of glass. An optical waveguide consisting of a core and cladding, which is capable of carrying information in the form of light. Fibre is also a general term used to cover all physical media types supported by Fibre Channel, such as optical fiber, twisted pair, and coaxial cable. Fiber Optics Light transmission through optical fibers for communication or signaling. Fibre Channel A high-speed, serial, bi-directional, topology independent, multi-protocol, highly scalable interconnection between computers, peripherals, and networks. Gb/s Gigabits per second or 1 billion bits per second. A reference to processing speed. GB/s Gigabytes per second or 1,073,741,824 bytes per second. A reference to processing speed. GLM Gigabit Link Module. A transmitter and receiver that provides high-speed serial links, enabling continuous throughput in each direction simultaneously. Host Adapter Module (HAM) A HAM is the driver component used to drive specific HBA hardware in the NetWare Peripheral Architecture (NPA). Interrupt Request (IRQ) Network boards are supplied with default settings for the IRQ, I/O port and base memory address. An IRQ is a signal protocol used by hardware devices, such as printers and modems, to let the computer know that they need some attention. When an IRQ is invoked, the CPU puts its other work “on hold” and services the needs of the interrupting device. Kilometer 1,000 meters or 3,281 feet. The kilometer is a unit of measurement commonly used in fiber optics. To convert kilometers to miles, multiply the number of kilometers by .62 to achieve the number of miles. To convert miles to kilometers, multiply the number of miles by 1.61 to achieve the number in kilometers. Laser Light Amplification by Stimulated Emission of Radiation. A device that produces coherent light with a narrow range of wavelengths. Latency Delay in transmission; can be caused by arbitration time prior to winning control of the network. Host Bus Adapter for Windows and Linux Installation Guide 85
  • 86. Glossary Light In the laser and optical communication fields, the portion of the electromagnetic spectrum that can be handled by the basic optical techniques used for the visible spectrum extending from the near ultraviolet region of approximately 0.3 micron, through the visible region, and into the mid-infrared region of about 30 microns. Light Emitting Diode (LED) A device used in a transmitter to convert information from electrical to optical form. It typically has a large spectral width. Lightwaves Electromagnetic waves in the region of optical frequencies. The term “light” was originally restricted to radiation visible to the human eye, with wavelengths between 400 and 700 nanometers (nm). However, it has become customary to refer to radiation in the spectral regions adjacent to visible light (in the near infrared from 700 to about 2000 nm) as “light” to emphasize the physical and technical characteristics. Link A fiber optic cable with connectors attached to a transmitter (source) and receiver (detector). Longwave Refers to length of the wave or frequency in the spectrum of light. 780 nm is the operating range of short wave lasers, while 1300 nm describes the range of long wave lasers. LUN Logical Unit Number. A three-bit identifier for a Logical Unit. The maximum number of LUNs per SCSI target is 8, numbered LUN0 through LUN7. Mb/s Megabits per second or 1,000 bits per second. A reference to processing speed. MB/s Megabytes per second or 1,000 bytes per second. A reference to processing speed. Media Manager (MM) A database built into NetWare that keeps track of all peripheral storage devices and media attached to NetWare servers, and allows applications to gain access and get information. The Media Manager receives application I/O requests and converts them to messages compatible with the NPA architecture. Micron (mm) Another term for micrometer. One millionth of a meter. 10-6 meter. Mode A term used to describe a light path through a fiber, as in multi-mode or single-mode. 86 Host Bus Adapter for Windows and Linux Installation Guide
  • 87. Glossary Multi-initiators Two different Fibre Channel HBAs in one arbitrated loop sharing the same storage devices, but not communicating with each other. Multi-Mode Fiber An optical waveguide in which light travels in multiple modes. Typical core/cladding sizes (measured in microns) are 50/125, 62.5/125, and 100/140. Multiplexing The process by which two or more signals are transmitted over a single communications channel. NetWare Peripheral Architecture (NWPA) Network architecture that provides a broader and more reliable driver support for third-party host adapters and storage devices. The NPWA separates NetWare driver support into two components: a Host Adapter Module (HAM), and a Custom Device Module (CDM). See also Custom Device Module and Host Adapter Module. nm Nanometer. A unit of measurement equal to one billionth of a meter. 10-9 meter. Non-OFC Non-Open Fiber Control. GLMs that do not contain OFC control but still guarantee laser emission levels to be below Class 1. OFC Open Fiber Control. A power monitoring/control system which continuously monitors the optical fiber link between two ports and prevents any laser emission from exceeding Class 1 levels in the event of a break anywhere in the path. Optical Waveguide Dielectric waveguide with a core consisting of optically transparent material or low attenuation (usually silica glass) and with cladding consisting of optically transparent material of lower refractive index than that of the core. It is used for the transmission of signals with lightwaves and is frequently referred to as fiber. PCI Bus # An internal Peripheral Connect Interface bus number in a computer. PCI Bus # is set by the computer system’s BIOS, and in most cases, the number is zero. PCI Device # PCI slot number in a computer. Point-To-Point (PTP) A connection established between two specific locations, as between two buildings. Host Bus Adapter for Windows and Linux Installation Guide 87
  • 88. Glossary Protocol A data transmission convention encompassing timing, control, formatting, and data representation. SCSI Small Computer Systems Interface. SelectID Used to configure Seagate drives. A matrix for relating ALPA (hex) numbers to SelectID (hex) numbers. Shortwave Refers to length of the wave or frequency in the spectrum of light. 780 nm is the operating range of short wave lasers, while 1300nm describes the range of long wave lasers. Simplex Cable A term sometimes used for a single-fiber cable. Simplex Transmission Transmission in one direction only. Single-Mode Fiber An optical waveguide (or fiber) with a small core diameter in which only a single mode is capable of propagation. This type of fiber is particularly suitable for wideband transmission over large distances, since its bandwidth is limited only by chromatic dispersion. Topology The logical and/or physical arrangement of stations on a network. Transducer A device for converting energy from one form to another, such as optical energy to electrical energy. ULP Upper Level Protocol. Waveguide Structure that guides electromagnetic waves along its length. An optical fiber is an optical waveguide. Wavelength The distance between two crests of an electromagnetic waveform. 88 Host Bus Adapter for Windows and Linux Installation Guide
  • 89. index A E A7298A host bus adapter See HBAs equipment symbols 10 agency approvals 21 Al_PA addresses, table of 76 F audience 8 fabric device mapping 57 authorized reseller, HP 13 FCC Compliance notice 79 Federal Communications Commission notice 81 B Boot BIOS G definition 19 getting help 13 C H CmdStat values 54 HBAs configuration agency approvals 21 guidelines for HBAs 29 configuration guidelines 29 Index utilities 65 installation overview 23 Index conventions installation procedure 26 document 9 installation requirements 24 equipment symbols 10 POST LED results 50 text symbols 9 product description 15 recording reference numbers 25 D restarting 77 diagnostic utilities 65 standards 20 document verifying installation 28 conventions 9 viewing parameters 71 related documentation 8 help, obtaining 13 DOS Diagnostic utility HP installing 66 authorized reseller 13 main menu 69 storage website 13 overview 66 technical support 13 preliminary analysis with 67 driver parameters, table of 73 Host Bus Adapter for Windows and Linux Installation Guide 89
  • 90. Index I SCSI Miniport drivers installation event log codes 52 DOS Diagnostic utility 66 installing on Windows Server 2003 32 HBA overview 23 overview 31 HBA requirements 24 removing from Windows Server 2003 33 HBAs 26 Windows Server 2003 system requirements verifying HBA installation 28 32 showing HBA information 77 L standards, for HBAs 20 symbols in text 9 LightPulse Utility/NT symbols on equipment 10 input and output files 77 system requirements modifying driver parameters 73, 76, 77 HBA installation 24 modifying test options 77 overview 71 T restarting HBAs 77 showing HBA information 77 technical support, HP 13 viewing HBA parameters 71 test options, modifying 77 lputilnt, See LightPulse Utility/NT 71 text symbols 9 troubleshooting M CmdStat values 54 fabric device mapping 57 mapping parameter error values 55 fabric device 57 private loop device mapping 57 private loop device 57 SCSI address mapping 57 SCSI address 57 SCSI Miniport driver event logs 52 using POST LED results 50 P Windows Event Viewer 51 parameter error values 55 POST LED indicators, verifying HBA installation U 28, 50 utilities private loop device mapping, table of 58 DOS Diagnostic 66 LightPulse Utility/NT 71 R overview 65 rack stability, warning 12 reference numbers 25 V regulatory compliance notices viewing HBA parameters 71 FCC Compliance 79 Federal Communications Commission 81 W related documentation 8 warning S rack stability 12 symbols on equipment 10 SCSI address mapping 57 90 Host Bus Adapter for Windows and Linux Installation Guide
  • 91. Index websites removing 33 HP storage 13 system requirements 32 Windows Event log 51 Windows Event Viewer 51 X Windows Server 2003 x86DNLD, See DOS Diagnostic utility 66 SCSI Miniport drivers installing 32 Host Bus Adapter for Windows and Linux Installation Guide 91
  • 92. Index 92 Host Bus Adapter for Windows and Linux Installation Guide