SlideShare a Scribd company logo
IBM Easy-Connect
   System Networking
   - Transparent Mode
   - Multi-chassis Mode (PureFlex ONLY)
   - Customer Examples                        EN/CN4093 and Virtual Fabric Switch Module




Design and configuration by Scott Irwin & Igor Marty                      © 2013 IBM Corporation
What is Easy-Connect

    • Clever pass-through = Simple I/O module connecting servers,
      storage and the Core network

    • Aggregation = Server ports aggregated together towards Core
      Network

    • No network integration = Seen as one big pipe with server traffic
      coming in and out.

    • No Spanning-Tree = No loops, no network integration

    • Similar to Cisco FEX – with one important exception, server to
      server traffic stays local to chassis.

    • Specific Networking features (Virtual Fabric Mode, VMready etc…)
      can still be activated on selected ports when/if needed.



2                                                                         © 2013 IBM Corporation
Transparent Mode




                   © 2013 IBM Corporation
Easy-Connect
- Transparent Mode
Easy-Connect Transparent Mode
                             •   Looks like a “dumb” device to Nexus 5K/Edge Switch
                             •   No Spanning Tree Protocol (STP) – eliminates Network admin loop concerns
                             •   Provides traffic consolidation in the chassis to minimize ToR port utilization
                             •   Provides intra-chassis switching, even in Transparent Mode

Client Benefits
                             •   Allows client to manage networking from the Edge/Nexus management system
                             •   Allows for intra-chassis switching for optimal performance (i.e. vMotion)
                             •   Allows for pay as you grow expandability in the chassis, both to the network and the compute
                                 nodes.
 Networking Infrastructure




                             •   VLAN’s are transparent when in “Transparent Mode” between the NIC and Edge Switch
                             •   Allows for pNIC or Switch Independent vNIC to be utilized
                                   • Note: Power Nodes supported in pNIC mode only
                             •   Allows for growth into “Virtual Fabric Mode” using multiple groups and uplinks
                             •   Allows for FCoE if ONLY using a single Uplink (FCoE currently not supported over PortChannel)

How to set the I/O Switch into Transparent Mode
                             •  Set the uplinks as one logical unit via Static Port-Channel (note: VFSM support LACP when using
                                vNIC Groups)
                             • Turn on vNIC and configure all internal “ports” and external “port-channel” into vNIC “Group 1”
                             • Turn on Spanning Tree BPDU Guard and Edge on the Edge/Nexus Switch for additional
                                protection
                             Note: If connecting to a Nexus 2k both BPDU Guard and Edge are already enabled by default and
                                cannot be disabled.
                             • Works with PureFlex Chassis EN/CN4093 and Virtual Fabric Switch Modules
                             • If using FCoE over a single link simply enable CEE Globally (cee enable)              © 2013 IBM Corporation
Easy-Connect
Configuration to convert from Switch Mode to Transparent Mode
Configuration for the IBM VFSM and EN/CN4093
•ssh to each VFSM,EN/CN4093
•boot the VFSM,EN/CN4093 to use isCLI (Cisco-Like CLI) for a more familiar look
      • /boot/mode iscli
      • /boot/reset
      • /boot/prompt enable           enable if using FSM on PureFlex
•Set the following commands to convert to “Transparent Mode”
      • ssh to each VFSM
      • enter into enable mode (e.g. enable)
      • enter into configuration terminal mode (e.g. config t)
      • type the following; (start with factory default configuration)                                         vLAG
 Networking Infrastructure




                                                                           Switch               Switch          vPC
             “boot conf factory”
             ===========Begin Script ===========
             spanning-tree mode disable                                                                     LACP
             interface port ext1-ext10
             lacp key 1001                                                  VFSM 1             VFSM 2
             lacp mode active
                vnic enable
                vnic vnicgroup 1
                vlan 4091
                port int1-int14
                adminkey 1001                                                        Node
                enable
                failover
             exit                                                                    Chassis
             write memory
             ===========End Script ===========                                                  © 2013 IBM Corporation
Easy-Connect
Configuration to convert from Switch Mode to Transparent Mode w/FCoE
Configuration for the IBM VFSM and EN/CN4093
•ssh to each VFSM
•boot the VFSM to use isCLI (Cisco-Like CLI) for a more familiar look
      • /boot/mode iscli
      • /boot/reset
•Set the following commands to convert the VFSM to “Transparent Mode”
      • ssh to each VFSM
      • enter into enable mode (e.g. enable)
      • enter into configuration terminal mode (e.g. config t)
      • type the following; (start with factory default configuration)
             “boot conf factory”                                                                             vLAG
 Networking Infrastructure




                                                                         Switch              Switch           vPC
             ===========Begin Script ===========
             spanning-tree mode disable
             interface port ext1-ext4                                                                    LACP
             lacp key 1001
             lacp mode active                                            VFSM 1             VFSM 2
                vnic enable
                vnic vnicgroup 1
                vlan 4091
                port int1-int14
                adminkey 1001
                enable                                                            Node
                failover
             exit
             cee enable                                                           Chassis
             write memory
             ===========End Script ===========                                                © 2013 IBM Corporation
Multi-Chassis Mode




                     © 2013 IBM Corporation
Easy-Connect
- Multi-chassis Mode
  Easy-Connect Multi-chassis Mode
                             •   Allows G8264 and EN/CN4093 look like a “dumb” device to Edge/Nexus Switches
                             •   No Spanning Tree Protocol (STP) Required – eliminates Network admin loop concerns
                             •   Provides traffic consolidation in the chassis to minimize ToR port utilization
                             •   Provides intra chassis switching, even in Easy-Connect Mode
                             •   Works with EN/CN4093 ONLY as VFSM does NOT support vLAG

  Client Benefits
                             •   Allows client to manage networking from the Edge/Nexus management system
                             •   Allows for intra/external chassis switching for optimal performance (i.e. vMotion)
 Networking Infrastructure




                             •   Allows for pay as you grow expandability in the chassis, both to the network and the
                                 compute nodes.
                             •   VLAN’s are transparent on both G8264 and EN/CN4093 when in “Easy-Connect Mode”
                                 between the NIC and Upstream AGG/Core Switch
                             •   Allows for pNIC or Switch Independent vNIC to be utilized
                             •   Allows for growth into Virtual Fabric Mode
                             •   Note: Power Nodes supported in pNIC mode only

  Use cases for Multi-Chassis Mode
                             •   Works with environments that require Active/Active NIC Teaming and or Bonding using
                                 802.3ad and or Static EtherChannels on the NODE Ports
                             •   Works with both Intel and Power Nodes
                             •   ALL local Layer 2 Traffic, even if using different I/O Bays, will remain within the same
                                 enclosure with the use of the ISL Peer-Links between the EN/CN4093’s
                             •   Each Chassis appears to upstream Network as a single entity
                                                                                                                    © 2013 IBM Corporation
Easy-Connect
What you end up with in Multi-chassis Mode with vLAG and vPC
How-To: EN/CN4093 Easy-Connect Multi-chassis Mode

     Disable Global Spanning Tree

     Set all VFSM ports, both EXT Ports facing the Network (Top of
     Rack) and INT Ports, into tagpvid-ingress using VLAN 4091 as     Switch               Switch
                                                                                                          vLAG
                                                                                                          or vPC
     the PVID

     Enable TAGGING on the two EXT Ports being used as the vLAG
     Peer Link and set 4090 as the PVID adding VLAN 4091 as a                     LACP
     TAGGED/TRUNKED member (VLAN 4090 is used as the vLAG
     ISL VLAN)                                                       EN/CN4093            EN/CN4093        vLAG

     Configure all required LACP PortChannels (Peer Link, EXT, and               LACP
     INT Ports)

     Configure a dummy IP Address used by the MGT EXT Port
                                                                                 Node
     vLAG Health Check (e.g. 1.1.1.1 (SW1) and 1.1.1.2 (SW2))
                                                                                 X or P
     Configure vLAG ISL, Health Check peer-ip, and all associated
                                                                                 Chassis
     vLAG pairs


NOTE: Turning on Spanning Tree BPDU Guard and Edge on the
EDGE G8264 / Nexus 5K Switches can provide further protection

                                                                                            © 2013 IBM Corporation
Easy-Connect
If using G8264’s in ToR also in Multi-Chassis Transparent Mode
How-To: G8264 Easy-Connect Multi-chassis Mode
                                                                      vPC   AGG/Core             AGG/Core
     Disable Global Spanning Tree (not required (default is using
     Rapid PVST+ (i.e. PVRST)))                                      LACP

     Set all G8264 ports, both uplink facing network and enclosure   vLAG   G8264-1              G8264-2
     facing EN/CN4093’s, into tagpvid-ingress using VLAN 4091 as
     the PVID

     Enable TAGGING on the two ISL Ports being used as the vLAG                LACP                LACP
     Peer-Link and set 4090 as the PVID adding VLAN 4091 as a
     TAGGED/TRUNKED member (VLAN 4090 is used as the vLAG            vLAG   EN/CN4093            EN/CN4093
     ISL VLAN)
                                                                                        LACP
     Configure all required LACP PortChannels (Peer Link, Uplinks,
     and EN/CN4093 facing ports)
                                                                                        Node
     Configure a dummy IP Address used by the MGT Port vLAG
                                                                                        X or P
     Health Check (e.g. 1.1.1.1 (SW1) and 1.1.1.2 (SW2))
     NOTE: if using customers MGT Network set IP’s appropriately
                                                                                       Chassis

     Configure vLAG ISL, Health Check peer-ip, and all associated
     vLAG pairs


NOTE: Turning on Spanning Tree BPDU Guard and Edge on the
EDGE G8264 / Nexus 5K Switches can provide further protection                             © 2013 IBM Corporation
Customer requirements to implement Easy-Connect

     1. If using FSM in same chassis – since the FSM is NOT capable of TAGGING
        (Cisco Trunking) customer MUST enable the Top-of-Rack Port “Native
        VLAN ID” with the VLAN that the FSM needs to be configured on.

     2. ALL other OS’s (i.e. VMware, VIO, and even Bare Metal OS’s) within the
        PureFlex Chassis are required to TAG/Trunk VLAN’s.

     3. If using multiple vNIC Groups for traffic either traffic separation and or if
        using Virtual Fabric Mode - each vNIC Group requires it’s own
        uplink/PortChannel or DUM (Dedicated Uplink Mode)


     4. If Multi-Tenant security is a concern within the same PureFlex Chassis
        Easy-Connect may/may not be a good option. Why, because each vNIC
        Group is a single broadcast domain.

     5. If IGMP Multicast Snooping is required Easy-Connect may not be a best
        option. Since Easy-Connect is VLAN Agnostic IGMP Snooping is not
        supported in any Q-n-Q Architecture. However, Multicast will still pass
        through the Easy Connect enabled Switches.
11                                                                               © 2013 IBM Corporation
Easy Connect
Customer Examples




                    © 2013 IBM Corporation
Easy-Connect EN/CN4093
Transparent Mode – Telecom Customer (Very Simple)
 Requirements included:
 •No Spanning Tree and or any other protocols seen by the network (Easy-Connect)
 •Connection into Nexus 2k (no vPC or vLAG requirement)
 •EN4093 is to be a total transparent device requiring no management by any group




                                                                                    © 2013 IBM Corporation
Easy-Connect EN/CN4093
Transparent Mode – State Government
 Requirements included:
 •Using LoM in Virtual Fabric Mode so bandwidth can be adjusted on the fly for each vNIC as required
 •Dedicated uplink vPC PortChannel from each EN4093 for each vNIC Group for separation of traffic
 •EN4093’s in Transparent Mode with minimal hands-on requirement (vNIC BW ONLY)




                                                                                           © 2013 IBM Corporation
Easy-Connect EN/CN4093
Storage Mode w/NIC Redundancy – Medical Center
 Requirements included:
 •Dedication and Separation of Fiber Channel and Ethernet from Each NODE and Enclosure
 •Total Hardware Redundancy including NIC and ASIC on every NODE (CN4054 Mezz)
 •Transparency on both Ethernet (Easy-Connect) and Fiber Channel (NPV)




                                                                                         © 2013 IBM Corporation
Backup Slides




                © 2013 IBM Corporation
Four Scalable switches enable high speed connectivity – Ethernet
 (FCoE, iSCSI), Fibre Channel and InfiniBand




                                                  Four high
                                                 performance
                                                Scalable Switch
                                                   Modules




                        3    2     4
                  1




17
17                                                          © 2013 IBM Corporation
Robust connectivity: Switch, asic and adapter level redundancy
                                         Redundant pair
     asic level redundancy                                                     Redundant pair




                                     EN4093 (base)




                                                          EN4093 (base)




                                                                                                           EN4093 (base)
                                                                                     EN4093 (base)
            asic 1




            asic 2


  CN4054




                                     EN4093 (Upgrade 1)




                                                          EN4093 (Upgrade 1)




                                                                                                           EN4093 (Upgrade 1)
                                                                                      EN4093 (Upgrade 1)
            asic 1




            asic 2


   CN4054

                                       1                      3                          2                    4
Adapter level redundancy                                                                                   © 2013 IBM Corporation

More Related Content

What's hot (20)

PPSX
Juniper for Enterprise
MarketingArrowECS_CZ
 
PPTX
Cisco nexus series
Anwesh Dixit
 
PPT
Cisco data center support
Krunal Shah
 
PPT
Day 14.2 configuringvla ns
CYBERINTELLIGENTS
 
PDF
Juniper Networks: Virtual Chassis High Availability
Juniper Networks
 
PDF
Matching Cisco and System p
Andrey Klyachkin
 
PDF
vPC techonology for full ha from dc core to baremetel server.
Ajeet Singh
 
PPTX
Virtual Routing and Forwarding, (VRF-lite)
NetProtocol Xpert
 
PPTX
Creating Competitive Advantage by Revolutionizing I/O
Emulex Corporation
 
PDF
WAN - trends and use cases
MarketingArrowECS_CZ
 
PDF
Inter VLAN Routing
Netwax Lab
 
PPT
Chapter 10
Suchit Aher
 
PPSX
From virtual to high end HW routing for the adult
MarketingArrowECS_CZ
 
PPTX
KPUCC-Rs instructor ppt_chapter3_final
Fisal Anwari
 
PDF
Vlans_routing
Farhaj Sidd
 
PPTX
VDC by NETWORKERS HOME
networkershome
 
PDF
Juniper Switch Overview
igxglobal UK Ltd
 
PPTX
Juniper round table switching and product overview
Kappa Data
 
PPT
Introduction to routers
Santosh Kulkarni
 
Juniper for Enterprise
MarketingArrowECS_CZ
 
Cisco nexus series
Anwesh Dixit
 
Cisco data center support
Krunal Shah
 
Day 14.2 configuringvla ns
CYBERINTELLIGENTS
 
Juniper Networks: Virtual Chassis High Availability
Juniper Networks
 
Matching Cisco and System p
Andrey Klyachkin
 
vPC techonology for full ha from dc core to baremetel server.
Ajeet Singh
 
Virtual Routing and Forwarding, (VRF-lite)
NetProtocol Xpert
 
Creating Competitive Advantage by Revolutionizing I/O
Emulex Corporation
 
WAN - trends and use cases
MarketingArrowECS_CZ
 
Inter VLAN Routing
Netwax Lab
 
Chapter 10
Suchit Aher
 
From virtual to high end HW routing for the adult
MarketingArrowECS_CZ
 
KPUCC-Rs instructor ppt_chapter3_final
Fisal Anwari
 
Vlans_routing
Farhaj Sidd
 
VDC by NETWORKERS HOME
networkershome
 
Juniper Switch Overview
igxglobal UK Ltd
 
Juniper round table switching and product overview
Kappa Data
 
Introduction to routers
Santosh Kulkarni
 

Viewers also liked (12)

PDF
NIC Virtualization on IBM Flex Systems
Angel Villar Garea
 
PDF
Deploying IBM Flex System into a Cisco Network
IBM India Smarter Computing
 
PDF
Lenovo midokura
Ashmar Kalangottil
 
PDF
IBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable Switches
IBM India Smarter Computing
 
PPT
Ibm pure flex overview cust pr
Natalija Pavic
 
PDF
IBM Systems of Interaction
IBM Sverige
 
PDF
Microsoft Exchange 2013 architecture
Motty Ben Atia
 
PDF
Cloud computing Basics
Sagar Sane
 
PPT
Cloud computing ppt
Datta Dharanikota
 
PPT
Cloud computing simple ppt
Agarwaljay
 
PPTX
Introduction of Cloud computing
Rkrishna Mishra
 
PPTX
cloud computing ppt
himanshuawasthi2109
 
NIC Virtualization on IBM Flex Systems
Angel Villar Garea
 
Deploying IBM Flex System into a Cisco Network
IBM India Smarter Computing
 
Lenovo midokura
Ashmar Kalangottil
 
IBM Flex System Fabric EN4093 and EN4093R 10Gb Scalable Switches
IBM India Smarter Computing
 
Ibm pure flex overview cust pr
Natalija Pavic
 
IBM Systems of Interaction
IBM Sverige
 
Microsoft Exchange 2013 architecture
Motty Ben Atia
 
Cloud computing Basics
Sagar Sane
 
Cloud computing ppt
Datta Dharanikota
 
Cloud computing simple ppt
Agarwaljay
 
Introduction of Cloud computing
Rkrishna Mishra
 
cloud computing ppt
himanshuawasthi2109
 
Ad

Similar to IBM System Networking Easy Connect Mode (20)

PDF
Presentation dc design for small and mid-size data center
xKinAnx
 
PPTX
Dc fabric path
ASHISH SEHGAL
 
PDF
EVPN: Migration from Legacy to Modern Architecture
6fm7gg7hxs
 
PPT
Ccna 9
Simanto Basher
 
PPTX
HP Virtual Connect technical fundamental101 v2.1
ผู้ชาย แห่งสายลม
 
PPT
Day 14.2 inter vlan
CYBERINTELLIGENTS
 
PPT
Icnd210 s02l01
computerlenguyen
 
PPTX
VMworld 2015: Networking Virtual SAN's Backbone
VMworld
 
PPTX
Vxlan deep dive session rev0.5 final
KwonSun Bae
 
PPTX
FlowER Erlang Openflow Controller
Holger Winkelmann
 
PPTX
Inf net2227 heath
reynolds_heath
 
PDF
Flexible NFV WAN interconnections with Neutron BGP VPN
Thomas Morin
 
PPTX
Logical_Routing_NSX_T_2.4.pptx.pptx
AnwarAnsari40
 
PDF
XS Boston 2008 XenLoop
The Linux Foundation
 
PDF
Vlan truks
1 2d
 
PDF
BRKACI-1003 ACI Brownfield Migration - Real World Experiences and Best Practi...
fcesargonca
 
PDF
PLNOG 5: Piotr Szołkowski - Data Center i nie tylko...
PROIDEA
 
PDF
Ies5000 usg
Advanced comm
 
DOC
Final exam ccna exploration 3 lan switching and wireless
kratos2424
 
PPTX
VLAN (Virtual Local Area Network) Full details.pptx
Vignesh kumar
 
Presentation dc design for small and mid-size data center
xKinAnx
 
Dc fabric path
ASHISH SEHGAL
 
EVPN: Migration from Legacy to Modern Architecture
6fm7gg7hxs
 
HP Virtual Connect technical fundamental101 v2.1
ผู้ชาย แห่งสายลม
 
Day 14.2 inter vlan
CYBERINTELLIGENTS
 
Icnd210 s02l01
computerlenguyen
 
VMworld 2015: Networking Virtual SAN's Backbone
VMworld
 
Vxlan deep dive session rev0.5 final
KwonSun Bae
 
FlowER Erlang Openflow Controller
Holger Winkelmann
 
Inf net2227 heath
reynolds_heath
 
Flexible NFV WAN interconnections with Neutron BGP VPN
Thomas Morin
 
Logical_Routing_NSX_T_2.4.pptx.pptx
AnwarAnsari40
 
XS Boston 2008 XenLoop
The Linux Foundation
 
Vlan truks
1 2d
 
BRKACI-1003 ACI Brownfield Migration - Real World Experiences and Best Practi...
fcesargonca
 
PLNOG 5: Piotr Szołkowski - Data Center i nie tylko...
PROIDEA
 
Ies5000 usg
Advanced comm
 
Final exam ccna exploration 3 lan switching and wireless
kratos2424
 
VLAN (Virtual Local Area Network) Full details.pptx
Vignesh kumar
 
Ad

More from IBM System Networking (14)

PPT
IBM Software Defined Networking for Virtual Environments (IBM SDN VE)
IBM System Networking
 
PPTX
Unified Fabric Architecture from BLADE Network Technologies
IBM System Networking
 
PPTX
Green Networking With Blade
IBM System Networking
 
PPTX
VMready Virtual Machine-aware Networking for HP
IBM System Networking
 
PPT
10G Ethernet Overview & Use Cases
IBM System Networking
 
PPTX
BLADE Company Overview
IBM System Networking
 
PPTX
BLADE RackSwitch
IBM System Networking
 
PPTX
IBM BladeCenter Switches
IBM System Networking
 
PPTX
HP BladeSystem Interconnects
IBM System Networking
 
PPT
BLADEHarmony Manager
IBM System Networking
 
PDF
BLADE Cloud Ready Network Architecture
IBM System Networking
 
PPT
10G Ethernet Outlook for HPC
IBM System Networking
 
PPT
Rackonomics and Network Virtualization with BLADE RackSwitch
IBM System Networking
 
IBM Software Defined Networking for Virtual Environments (IBM SDN VE)
IBM System Networking
 
Unified Fabric Architecture from BLADE Network Technologies
IBM System Networking
 
Green Networking With Blade
IBM System Networking
 
VMready Virtual Machine-aware Networking for HP
IBM System Networking
 
10G Ethernet Overview & Use Cases
IBM System Networking
 
BLADE Company Overview
IBM System Networking
 
BLADE RackSwitch
IBM System Networking
 
IBM BladeCenter Switches
IBM System Networking
 
HP BladeSystem Interconnects
IBM System Networking
 
BLADEHarmony Manager
IBM System Networking
 
BLADE Cloud Ready Network Architecture
IBM System Networking
 
10G Ethernet Outlook for HPC
IBM System Networking
 
Rackonomics and Network Virtualization with BLADE RackSwitch
IBM System Networking
 

Recently uploaded (20)

PDF
Productivity Management Software | Workstatus
Lovely Baghel
 
PDF
CIFDAQ'S Token Spotlight for 16th July 2025 - ALGORAND
CIFDAQ
 
PDF
2025-07-15 EMEA Volledig Inzicht Dutch Webinar
ThousandEyes
 
PDF
HR agent at Mediq: Lessons learned on Agent Builder & Maestro by Tacstone Tec...
UiPathCommunity
 
PDF
Alpha Altcoin Setup : TIA - 19th July 2025
CIFDAQ
 
PDF
State-Dependent Conformal Perception Bounds for Neuro-Symbolic Verification
Ivan Ruchkin
 
PDF
Peak of Data & AI Encore - Real-Time Insights & Scalable Editing with ArcGIS
Safe Software
 
PDF
GDG Cloud Munich - Intro - Luiz Carneiro - #BuildWithAI - July - Abdel.pdf
Luiz Carneiro
 
PPTX
AVL ( audio, visuals or led ), technology.
Rajeshwri Panchal
 
PDF
Arcee AI - building and working with small language models (06/25)
Julien SIMON
 
PDF
Integrating IIoT with SCADA in Oil & Gas A Technical Perspective.pdf
Rejig Digital
 
PDF
Agentic Artificial Intelligence (AI) and its growing impact on business opera...
Alakmalak Technologies Pvt. Ltd.
 
PDF
Meetup Kickoff & Welcome - Rohit Yadav, CSIUG Chairman
ShapeBlue
 
PDF
How Current Advanced Cyber Threats Transform Business Operation
Eryk Budi Pratama
 
PDF
NewMind AI Weekly Chronicles – July’25, Week III
NewMind AI
 
PDF
CloudStack GPU Integration - Rohit Yadav
ShapeBlue
 
PPTX
Simplifying End-to-End Apache CloudStack Deployment with a Web-Based Automati...
ShapeBlue
 
PPTX
Agile Chennai 18-19 July 2025 | Workshop - Enhancing Agile Collaboration with...
AgileNetwork
 
PPTX
Agile Chennai 18-19 July 2025 | Emerging patterns in Agentic AI by Bharani Su...
AgileNetwork
 
PPTX
Lecture 5 - Agentic AI and model context protocol.pptx
Dr. LAM Yat-fai (林日辉)
 
Productivity Management Software | Workstatus
Lovely Baghel
 
CIFDAQ'S Token Spotlight for 16th July 2025 - ALGORAND
CIFDAQ
 
2025-07-15 EMEA Volledig Inzicht Dutch Webinar
ThousandEyes
 
HR agent at Mediq: Lessons learned on Agent Builder & Maestro by Tacstone Tec...
UiPathCommunity
 
Alpha Altcoin Setup : TIA - 19th July 2025
CIFDAQ
 
State-Dependent Conformal Perception Bounds for Neuro-Symbolic Verification
Ivan Ruchkin
 
Peak of Data & AI Encore - Real-Time Insights & Scalable Editing with ArcGIS
Safe Software
 
GDG Cloud Munich - Intro - Luiz Carneiro - #BuildWithAI - July - Abdel.pdf
Luiz Carneiro
 
AVL ( audio, visuals or led ), technology.
Rajeshwri Panchal
 
Arcee AI - building and working with small language models (06/25)
Julien SIMON
 
Integrating IIoT with SCADA in Oil & Gas A Technical Perspective.pdf
Rejig Digital
 
Agentic Artificial Intelligence (AI) and its growing impact on business opera...
Alakmalak Technologies Pvt. Ltd.
 
Meetup Kickoff & Welcome - Rohit Yadav, CSIUG Chairman
ShapeBlue
 
How Current Advanced Cyber Threats Transform Business Operation
Eryk Budi Pratama
 
NewMind AI Weekly Chronicles – July’25, Week III
NewMind AI
 
CloudStack GPU Integration - Rohit Yadav
ShapeBlue
 
Simplifying End-to-End Apache CloudStack Deployment with a Web-Based Automati...
ShapeBlue
 
Agile Chennai 18-19 July 2025 | Workshop - Enhancing Agile Collaboration with...
AgileNetwork
 
Agile Chennai 18-19 July 2025 | Emerging patterns in Agentic AI by Bharani Su...
AgileNetwork
 
Lecture 5 - Agentic AI and model context protocol.pptx
Dr. LAM Yat-fai (林日辉)
 

IBM System Networking Easy Connect Mode

  • 1. IBM Easy-Connect System Networking - Transparent Mode - Multi-chassis Mode (PureFlex ONLY) - Customer Examples EN/CN4093 and Virtual Fabric Switch Module Design and configuration by Scott Irwin & Igor Marty © 2013 IBM Corporation
  • 2. What is Easy-Connect • Clever pass-through = Simple I/O module connecting servers, storage and the Core network • Aggregation = Server ports aggregated together towards Core Network • No network integration = Seen as one big pipe with server traffic coming in and out. • No Spanning-Tree = No loops, no network integration • Similar to Cisco FEX – with one important exception, server to server traffic stays local to chassis. • Specific Networking features (Virtual Fabric Mode, VMready etc…) can still be activated on selected ports when/if needed. 2 © 2013 IBM Corporation
  • 3. Transparent Mode © 2013 IBM Corporation
  • 4. Easy-Connect - Transparent Mode Easy-Connect Transparent Mode • Looks like a “dumb” device to Nexus 5K/Edge Switch • No Spanning Tree Protocol (STP) – eliminates Network admin loop concerns • Provides traffic consolidation in the chassis to minimize ToR port utilization • Provides intra-chassis switching, even in Transparent Mode Client Benefits • Allows client to manage networking from the Edge/Nexus management system • Allows for intra-chassis switching for optimal performance (i.e. vMotion) • Allows for pay as you grow expandability in the chassis, both to the network and the compute nodes. Networking Infrastructure • VLAN’s are transparent when in “Transparent Mode” between the NIC and Edge Switch • Allows for pNIC or Switch Independent vNIC to be utilized • Note: Power Nodes supported in pNIC mode only • Allows for growth into “Virtual Fabric Mode” using multiple groups and uplinks • Allows for FCoE if ONLY using a single Uplink (FCoE currently not supported over PortChannel) How to set the I/O Switch into Transparent Mode • Set the uplinks as one logical unit via Static Port-Channel (note: VFSM support LACP when using vNIC Groups) • Turn on vNIC and configure all internal “ports” and external “port-channel” into vNIC “Group 1” • Turn on Spanning Tree BPDU Guard and Edge on the Edge/Nexus Switch for additional protection Note: If connecting to a Nexus 2k both BPDU Guard and Edge are already enabled by default and cannot be disabled. • Works with PureFlex Chassis EN/CN4093 and Virtual Fabric Switch Modules • If using FCoE over a single link simply enable CEE Globally (cee enable) © 2013 IBM Corporation
  • 5. Easy-Connect Configuration to convert from Switch Mode to Transparent Mode Configuration for the IBM VFSM and EN/CN4093 •ssh to each VFSM,EN/CN4093 •boot the VFSM,EN/CN4093 to use isCLI (Cisco-Like CLI) for a more familiar look • /boot/mode iscli • /boot/reset • /boot/prompt enable  enable if using FSM on PureFlex •Set the following commands to convert to “Transparent Mode” • ssh to each VFSM • enter into enable mode (e.g. enable) • enter into configuration terminal mode (e.g. config t) • type the following; (start with factory default configuration) vLAG Networking Infrastructure Switch Switch vPC “boot conf factory” ===========Begin Script =========== spanning-tree mode disable LACP interface port ext1-ext10 lacp key 1001 VFSM 1 VFSM 2 lacp mode active vnic enable vnic vnicgroup 1 vlan 4091 port int1-int14 adminkey 1001 Node enable failover exit Chassis write memory ===========End Script =========== © 2013 IBM Corporation
  • 6. Easy-Connect Configuration to convert from Switch Mode to Transparent Mode w/FCoE Configuration for the IBM VFSM and EN/CN4093 •ssh to each VFSM •boot the VFSM to use isCLI (Cisco-Like CLI) for a more familiar look • /boot/mode iscli • /boot/reset •Set the following commands to convert the VFSM to “Transparent Mode” • ssh to each VFSM • enter into enable mode (e.g. enable) • enter into configuration terminal mode (e.g. config t) • type the following; (start with factory default configuration) “boot conf factory” vLAG Networking Infrastructure Switch Switch vPC ===========Begin Script =========== spanning-tree mode disable interface port ext1-ext4 LACP lacp key 1001 lacp mode active VFSM 1 VFSM 2 vnic enable vnic vnicgroup 1 vlan 4091 port int1-int14 adminkey 1001 enable Node failover exit cee enable Chassis write memory ===========End Script =========== © 2013 IBM Corporation
  • 7. Multi-Chassis Mode © 2013 IBM Corporation
  • 8. Easy-Connect - Multi-chassis Mode Easy-Connect Multi-chassis Mode • Allows G8264 and EN/CN4093 look like a “dumb” device to Edge/Nexus Switches • No Spanning Tree Protocol (STP) Required – eliminates Network admin loop concerns • Provides traffic consolidation in the chassis to minimize ToR port utilization • Provides intra chassis switching, even in Easy-Connect Mode • Works with EN/CN4093 ONLY as VFSM does NOT support vLAG Client Benefits • Allows client to manage networking from the Edge/Nexus management system • Allows for intra/external chassis switching for optimal performance (i.e. vMotion) Networking Infrastructure • Allows for pay as you grow expandability in the chassis, both to the network and the compute nodes. • VLAN’s are transparent on both G8264 and EN/CN4093 when in “Easy-Connect Mode” between the NIC and Upstream AGG/Core Switch • Allows for pNIC or Switch Independent vNIC to be utilized • Allows for growth into Virtual Fabric Mode • Note: Power Nodes supported in pNIC mode only Use cases for Multi-Chassis Mode • Works with environments that require Active/Active NIC Teaming and or Bonding using 802.3ad and or Static EtherChannels on the NODE Ports • Works with both Intel and Power Nodes • ALL local Layer 2 Traffic, even if using different I/O Bays, will remain within the same enclosure with the use of the ISL Peer-Links between the EN/CN4093’s • Each Chassis appears to upstream Network as a single entity © 2013 IBM Corporation
  • 9. Easy-Connect What you end up with in Multi-chassis Mode with vLAG and vPC How-To: EN/CN4093 Easy-Connect Multi-chassis Mode Disable Global Spanning Tree Set all VFSM ports, both EXT Ports facing the Network (Top of Rack) and INT Ports, into tagpvid-ingress using VLAN 4091 as Switch Switch vLAG or vPC the PVID Enable TAGGING on the two EXT Ports being used as the vLAG Peer Link and set 4090 as the PVID adding VLAN 4091 as a LACP TAGGED/TRUNKED member (VLAN 4090 is used as the vLAG ISL VLAN) EN/CN4093 EN/CN4093 vLAG Configure all required LACP PortChannels (Peer Link, EXT, and LACP INT Ports) Configure a dummy IP Address used by the MGT EXT Port Node vLAG Health Check (e.g. 1.1.1.1 (SW1) and 1.1.1.2 (SW2)) X or P Configure vLAG ISL, Health Check peer-ip, and all associated Chassis vLAG pairs NOTE: Turning on Spanning Tree BPDU Guard and Edge on the EDGE G8264 / Nexus 5K Switches can provide further protection © 2013 IBM Corporation
  • 10. Easy-Connect If using G8264’s in ToR also in Multi-Chassis Transparent Mode How-To: G8264 Easy-Connect Multi-chassis Mode vPC AGG/Core AGG/Core Disable Global Spanning Tree (not required (default is using Rapid PVST+ (i.e. PVRST))) LACP Set all G8264 ports, both uplink facing network and enclosure vLAG G8264-1 G8264-2 facing EN/CN4093’s, into tagpvid-ingress using VLAN 4091 as the PVID Enable TAGGING on the two ISL Ports being used as the vLAG LACP LACP Peer-Link and set 4090 as the PVID adding VLAN 4091 as a TAGGED/TRUNKED member (VLAN 4090 is used as the vLAG vLAG EN/CN4093 EN/CN4093 ISL VLAN) LACP Configure all required LACP PortChannels (Peer Link, Uplinks, and EN/CN4093 facing ports) Node Configure a dummy IP Address used by the MGT Port vLAG X or P Health Check (e.g. 1.1.1.1 (SW1) and 1.1.1.2 (SW2)) NOTE: if using customers MGT Network set IP’s appropriately Chassis Configure vLAG ISL, Health Check peer-ip, and all associated vLAG pairs NOTE: Turning on Spanning Tree BPDU Guard and Edge on the EDGE G8264 / Nexus 5K Switches can provide further protection © 2013 IBM Corporation
  • 11. Customer requirements to implement Easy-Connect 1. If using FSM in same chassis – since the FSM is NOT capable of TAGGING (Cisco Trunking) customer MUST enable the Top-of-Rack Port “Native VLAN ID” with the VLAN that the FSM needs to be configured on. 2. ALL other OS’s (i.e. VMware, VIO, and even Bare Metal OS’s) within the PureFlex Chassis are required to TAG/Trunk VLAN’s. 3. If using multiple vNIC Groups for traffic either traffic separation and or if using Virtual Fabric Mode - each vNIC Group requires it’s own uplink/PortChannel or DUM (Dedicated Uplink Mode) 4. If Multi-Tenant security is a concern within the same PureFlex Chassis Easy-Connect may/may not be a good option. Why, because each vNIC Group is a single broadcast domain. 5. If IGMP Multicast Snooping is required Easy-Connect may not be a best option. Since Easy-Connect is VLAN Agnostic IGMP Snooping is not supported in any Q-n-Q Architecture. However, Multicast will still pass through the Easy Connect enabled Switches. 11 © 2013 IBM Corporation
  • 12. Easy Connect Customer Examples © 2013 IBM Corporation
  • 13. Easy-Connect EN/CN4093 Transparent Mode – Telecom Customer (Very Simple) Requirements included: •No Spanning Tree and or any other protocols seen by the network (Easy-Connect) •Connection into Nexus 2k (no vPC or vLAG requirement) •EN4093 is to be a total transparent device requiring no management by any group © 2013 IBM Corporation
  • 14. Easy-Connect EN/CN4093 Transparent Mode – State Government Requirements included: •Using LoM in Virtual Fabric Mode so bandwidth can be adjusted on the fly for each vNIC as required •Dedicated uplink vPC PortChannel from each EN4093 for each vNIC Group for separation of traffic •EN4093’s in Transparent Mode with minimal hands-on requirement (vNIC BW ONLY) © 2013 IBM Corporation
  • 15. Easy-Connect EN/CN4093 Storage Mode w/NIC Redundancy – Medical Center Requirements included: •Dedication and Separation of Fiber Channel and Ethernet from Each NODE and Enclosure •Total Hardware Redundancy including NIC and ASIC on every NODE (CN4054 Mezz) •Transparency on both Ethernet (Easy-Connect) and Fiber Channel (NPV) © 2013 IBM Corporation
  • 16. Backup Slides © 2013 IBM Corporation
  • 17. Four Scalable switches enable high speed connectivity – Ethernet (FCoE, iSCSI), Fibre Channel and InfiniBand Four high performance Scalable Switch Modules 3 2 4 1 17 17 © 2013 IBM Corporation
  • 18. Robust connectivity: Switch, asic and adapter level redundancy Redundant pair asic level redundancy Redundant pair EN4093 (base) EN4093 (base) EN4093 (base) EN4093 (base) asic 1 asic 2 CN4054 EN4093 (Upgrade 1) EN4093 (Upgrade 1) EN4093 (Upgrade 1) EN4093 (Upgrade 1) asic 1 asic 2 CN4054 1 3 2 4 Adapter level redundancy © 2013 IBM Corporation

Editor's Notes

  • #2: March 20, 2013 BLADE Network Technologies, An IBM Company
  • #4: March 20, 2013 BLADE Network Technologies, An IBM Company
  • #8: March 20, 2013 BLADE Network Technologies, An IBM Company
  • #10: EN/CN4093 configuration to support Multi-Chassis Mode (OS Version 7.5.1) ssh to each EN/CN4093 boot to isCLI (Cisco-Like CLI) /boot/mode iscli /boot/reset Set the following commands to convert the EN/CN4093 into “Multi-chassis Mode” ssh to each EN/CN4093 enter into enable mode (e.g. enable) enter into configuration terminal mode (e.g. config t) type the following; (note: the IP Address of the health check “IP 127” Address will be different on both switch, everything else should remain the same) ===========Begin Script =========== spanning-tree mode disable interface port ext9,ext10  ISL vLAG Peer-Link Ports pvid 4090 tagging lacp key 1001 lacp mode active vlan 4090 enable name Peer-Link vlan 4091  Note: if using Power-Nodes also and want in separate domain (including uplinks (a MUST)) use VLAN 4092 enable name Intel-Nodes member int1-int14,ext1-ext4,ext9,ext10 interface port inta1-inta14,ext1-ext4 tagpvid-ingress interface port ext1-ext4  uplink ports to AGG/Core lacp key 4091  use SAME key on both VFSM INTEL Uplinks (4091) lacp mode active interface port inat1  INTa1 on both Switches will be in same PortChannel using vLAG (lacp key MUST match) lacp key 101 lacp mode active interface port inat2 lacp key 102 lacp mode active interface ip 127  IP 127 is dedicated to the MGT Port used for vLAG health check ip address 1.1.1.1 enable vlag ena vlag isl peer-ip 1.1.1.2  other switch will use 1.1.1.1 vlag isl vlan 4090 vlag isl adminkey 1001 vlag tier-id 10  each pair of switches connecting to each other should be a different Tier-ID vlag adminkey 4091 enable vlag adminkey 101 enable vlag adminkey 102 enable  repeat for each Server using 802.3ad / LACP write memory ===========End Script ===========
  • #11: G8264 configuration to support Multi-Chassis Mode (OS Version 7.5.1) ssh to each G8264 Note: G8264 uses isCLI by default Set the following commands to convert the G8264 into “Multi-chassis Mode” ssh to each G8264 enter into enable mode (e.g. enable) enter into configuration terminal mode (e.g. config t) type the following; (note: the IP Address of the health check “IP 128” Address will be different on both switch, everything else should remain the same) ===========Begin Script =========== spanning-tree mode disable  Optional interface port 1,5  2x 40Gb ISL (e.g. between G8264 ’s) tagging pvid 4090 lacp key 4090 lacp mode active vlan 4090 enable name Peer-Link vlan 4091 enable name “Transparent-Ports” interface port 17-64  Uplinks and EN/CN4093 facing Ports ONLY tagpvid-ingress interface port 17,18  uplink ports to AGG/Core lacp key 1001 lacp mode active interface port 19,20  Ports facing first PureFlex enclosure lacp key 1920 lacp mode active interface port 21,22 lacp key 2122  Ports facing second PureFlex enclosure lacp mode active vlag ena vlag isl adminkey 4090 vlag tier-id 1 vlag adminkey 1001 ena  Uplink PortChannel to AGG/Core vlag adminkey 1920 ena vlag adminkey 2122 ena  repeat for each Port-Channel to each EN/CN4093 write memory ===========End Script ===========
  • #13: March 20, 2013 BLADE Network Technologies, An IBM Company
  • #17: March 20, 2013 BLADE Network Technologies, An IBM Company