0% found this document useful (0 votes)
60 views

Experiment No. 07 (Sampling and Re-Construction of Signals)

The document describes an experiment to verify the sampling theorem and observe aliasing using a sampling and reconstruction trainer kit. The experiment involves sampling a 1 kHz sine wave signal at different sampling frequencies, observing the sampled and reconstructed signals using 2nd and 4th order low-pass filters, and analyzing the effects of duty cycle variation on reconstruction. The objectives are to demonstrate that sampling must be done at least twice the maximum frequency per Nyquist's theorem and to observe how reconstruction is affected by filter order and duty cycle.

Uploaded by

Siam Hasan
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views

Experiment No. 07 (Sampling and Re-Construction of Signals)

The document describes an experiment to verify the sampling theorem and observe aliasing using a sampling and reconstruction trainer kit. The experiment involves sampling a 1 kHz sine wave signal at different sampling frequencies, observing the sampled and reconstructed signals using 2nd and 4th order low-pass filters, and analyzing the effects of duty cycle variation on reconstruction. The objectives are to demonstrate that sampling must be done at least twice the maximum frequency per Nyquist's theorem and to observe how reconstruction is affected by filter order and duty cycle.

Uploaded by

Siam Hasan
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Experiment No.

07 (Sampling and Re-construction of Signals )

Object:-
(a) Experimentally verify the Sampling Theorem and observe the Aliasing effect, using the
Scientech Sampling Trainer Kit model ST-2101. Trace the “Sampled signal” at any three
different sampling frequencies.
(b) Observe the effect of the variation of duty cycle of the sampling pulses and the order of the low-
pass filter on the re-construction of the sampled signal. Trace the wave-shapes of the re-constructed
nd th
signal using 2 order and 4 order LPF.
Apparatus Used:-
1. Sampling and Reconstruction Trainer kit, model ST-2101 (Scientech Technologies)
2. A 20 MHz, dual channel Oscilloscope.

Brief Theory
NYQUIST CRITERION (Sampling Theorem):-
The Nyquist criterion states that a continuous signal band limited to f Hz, can be completely
m
represented by and reconstructed from, the samples taken at a rate greater than or equal to 2 f
m
samples per second. This minimum frequency is called as "Nyquist Rate". Thus, for the faithful
reconstruction of the information signal from its samples, it is necessary that the sampling rate, f
s
must be greater than 2f .
m
Aliasing;-
If the information signal is sampled at a rate lower than that stated by Nyquist criterion, than there
is an overlap between the information signal and the side bands of the harmonics. Thus the lower
and the higher frequency components get mixed and cause unwanted signals to appear at the
demodulator output. This phenomenon is termed as Aliasing or Fold-over Distortion. The various
reasons for aliasing and the ways for its prevention may be summarized as under:-
A) Aliasing due to under-Sampling:-
If the signal is sampled at a rate lower than 2 f , then it causes aliasing, as illustrated in the following figure, 
m
where a sinusoidal signal of frequency f is being sampled at a rate f <2 f , and the dots represent the 
m  s m
sample points.  
The LPF at demodulator effectively joins the sample causing an unwanted frequency component to appear 
at the output. This unwanted component has a frequency = (fs – fm)  
B) Aliasing due to wide band signal:‐  
The system is designed to take samples at a frequency slightly greater than that stated ny Nyquist rate. If 
higher frequencies are ever present in the information signal, or it is affected by H. F. noise, then the 
aliasing will occur. To prevent the aliasing, Anti‐aliasing filters are usually installed prior to sampling. In 
telephone networks, the speech signals are band‐limited by filters before sampling to avoid the effect of 
aliasing.  
C) Aliasing due to noise:‐  
If very small duty cycle is used in sample‐and‐hold circuit, aliasing may occur if the signal has been affected 
by the noise. High frequency noise generally mix with the High frequency component of the signal. and 
hence causes undesirable frequency components to appear at the output. This type of aliasing may, 
therefore, be prevented by slightly increasing the duty cycle of the sampling pulses.  
D) Aliasing due to Filter Roll‐off :‐  
Aliasing may also occur, if appropriate filter response is not chosen and the frequencies above the nominal 
cut‐off frequency of the filter, have significant amplitudes at the filter's output. This is called Aliasing due to 
Filter Roll‐off.  
Brief Description of the Kit  
Er M. Hadi Ali Khan                                                 Page 1                  http://mhakhan.tripod.com/lab.html

 
The lay‐out diagram of the experimental kit is shown on the next page:‐  
The kit contains the circuits for the following five sections: ‐  
1. Sampling Frequency Selector Section:‐  
By default, the sampling frequency is set to 32 KHz. But pushing successively the sampling frequency 
selector switch can change it and the value of the selected frequency is one‐tenth of the frequency 
indicated by the corresponding glowing LED. For example, if the LED corresponding to 20 KHz is glowing, 
then the selected value of the sampling frequency is 2 KHz.  
2. Duty cycle control section:‐  
Here the duty cycle of the sampling pulses can be varied from 10% to 90%.  
3. Sampling Section:‐  
It provides: Sampled “ output at TP‐37 and the “sample and hold” output at TP‐39. The input sampling 
pulses are also selected in this section by the INTERNAL / EXTERNAL sampling selector switch.  
 NB:‐  The internal pulses are usually selected; because the external pulses need to be synchronized with 
the information signal (1 KHz internally generated sinusoidal signal available at TP‐12 on the sampling 
frequency selection circuit board) to get the stable trace on the CRO screen.  
4. Two Low‐pass Filter sections:‐  
The 2nd order and 4th order LPFs, which provide the reconstructed signal at their outputs, TP‐42 and TP‐46 
respectively.  
The 4th order and the 2nd order Low Pass Filters:‐  
The nth order filter has a rate of fall off of 6n dB/Octave or 20ndB/decade and one capacitor or inductor is 
required for each pole (order). The following table summarizes the effect of fall‐off gradient on a signal 
such as square wave:‐ 
 

PROCEDURE:‐  

1. Set the INTERNAL / EXTERNAL sampling selector switch in INTERNAL position.  

2. Put the DUTY CYCLE SELECTOR switch in position 5 (to set 50 % duty cycle).  

3. Connect 1 KHz internally generated sinusoidal signal available at tp12 to SIGNAL INPUT on the Sampling 
Circuit board.  

4. Now, turn the ON/OFF switch of the kit to ON.  

5. Observe the information signal (1 KHz at tp12) on one channel and the Sample output (at TP‐37) on the 
other channel of the CRO.  

6. Connect the Sample Output (TP‐37) to the input of 4th order LPF.  

7. Trace the Sampled output at TP‐37. Note that 32 samples are appearing in one cycle of the information 
signal, as the default value of the sampling frequency is 32 KHz.  

8. Now, keep on reducing the sampling frequency in steps and trace the sampled output at any other two 
values of the sampling frequencies.  

9. Observe the reconstructed signal at the output of the 4th order LPF at tp46 on setting the sampling 
frequency equal to 2 KHz. Note that it is distorted as fs = 2 fm  

(Ref: Nyquist criteria).  

Er M. Hadi Ali Khan                                                 Page 2                  http://mhakhan.tripod.com/lab.html

 
10. Now, Connect the Sample Output (TP‐37) to the input of 2nd order LPF, and observe the reconstructed 
signal at the output of the 2nd order LPF (TP‐42) at different values of sampling frequencies. Compare the 
outputs of both the LPFs for the same value of sampling frequency. Which one is better and why? This 
completes the first part of the experiment. 

11. For the second part, keep the sampling rate constant at some appropriate value (say 8 or 16 KHz), and 
vary the position of DUTY CYCLE SELECTOR switch, and observe the Sampled signal (TP‐37) and the 
reconstructed signal at the output of the 4th order LPF (TP‐46) and also at the output of the 2nd order LPF 
(TP‐42) at different values of the duty cycle varying from 40 % (position 4) to 90 % (position 9 of duty cycle 
selector switch). Record your observations. How does the amplitude of the reconstructed signal vary with 
the variation of the duty cycle?  

12. Now, disconnect the sample output (TP‐37) from the input of the LPF and connect “Sample and Hold 
output (TP‐39) to the inputs of the LPFs, and observe the reconstructed signals at their outputs one by one.  

13. Vary the duty cycle again and observe that the reconstructed signal has now become independent of 
duty cycle variation. Measure the amplitude of the reconstructed signal at (TP‐46) and at (TP‐42) one by 
one.  

14. Comment on the results obtained by using the 4th order LPF and the 2nd order LPF. 

OBSERVATIONS:‐  
For a 1 KHz sine wave (internal information signal at TP‐12) and for 50 % duty cycle pulses,  
Minimum sampling rate for undistorted reconstructed signal using 4th order LPF =  
Minimum sampling rate for undistorted reconstructed signal using 2nd order LPF =  
Tabulate your observations for the second part of the experiment:‐  
 
RESULTs & Comments:‐  
References:‐  
1) B. P. Lathi : Communication Systems  
2) Scientech Technologies Pvt. Ltd. : WORK BOOK of Sampling and Reconstruction Trainer ST‐2101 WB  
3) Scientech Technologies Pvt.Ltd. : Operating Manual of Sampling and Reconstruction Trainer ST‐2101 OM  
 
*************** 
 
The lay‐out diagram of the experimental kit , model ST‐2101 is shown on the following page:‐ 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Er M. Hadi Ali Khan                                                 Page 3                  http://mhakhan.tripod.com/lab.html

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Er M. Hadi Ali Khan                                                 Page 4                  http://mhakhan.tripod.com/lab.html

You might also like