Assignment on RC II
Assignment on RC II
2024GC
1) A typical flat-slab system of building frame shown in Figure 1 is subjected to floor live load of
3.75𝐾𝑁/𝑚2 and dead load 1.5𝐾𝑁/𝑚2 for partition and floor finishing in addition to its self-weight.
Use thickness of slab 200𝑚𝑚 , 20𝑚𝑚 nominal concrete cover to reinforcement, 𝐶25/30
concrete grade and 𝑆 − 400 steel grade.
a) Check the adequacy of the slab for punching shear around the column C-1.
b) Design the panel 𝑆1, using Straight bar reinforcement.
S1
2) The Structure shown below is a part of G+0 sway reinforced concrete frame. If column AB carries
a load from slab floor finishing 1.25KN/m2 and handrail load of 0.25KN/m act at the tip of the
cantilever in addition to the self-weight of the members (slab, beam and column). Consider the
service live load of 3KN/m2 uniformly distributed over the upper slab surface. Design the column
using concrete grade C-25/30, concrete unit weigh = 25KN/m3, fyk = 400Mpa for Steel, 25mm
concrete cover ,16mm diameter for longitudinal bar and 6mm diameter bar for stirrups. All
dimensions are in cm.