OmniPC 4.1 release notes document new features and resolved issues over multiple software versions: - Version 4.1R14 added new features to the OmniScan unit acquisition software. Versions 4.1R12 and 4.1R9 added support for new equipment and probes. Version 4.1R8 added functionality for phased array inspection. - Resolved issues across versions included fixes for delays between gain points, TOFD wedge angle displays, cursor skipping during analysis, and file path initialization. - Additional features incorporated an "Uncorrected" scanning technique, improved TOFD calibration workflows, and added the A-Scan to multiple layouts. Reports and interfaces were also

Uploaded by

ndtitc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views

ReleaseNote OmniPC 4.1

OmniPC 4.1 release notes document new features and resolved issues over multiple software versions: - Version 4.1R14 added new features to the OmniScan unit acquisition software. Versions 4.1R12 and 4.1R9 added support for new equipment and probes. Version 4.1R8 added functionality for phased array inspection. - Resolved issues across versions included fixes for delays between gain points, TOFD wedge angle displays, cursor skipping during analysis, and file path initialization. - Additional features incorporated an "Uncorrected" scanning technique, improved TOFD calibration workflows, and added the A-Scan to multiple layouts. Reports and interfaces were also

Uploaded by

ndtitc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

OmniPC 4.

1 Release Notes

OmniPC 4.1R14 2015-02-04

New features
- New features were limited to the OmniScan unit acquisition software (MXU) for this release.

OmniPC 4.1R12 2014-12-23

Resolved issues from previous version


- Depending on the instrument’s configuration, a delay between TCG point and the application of the
associated gain was sometimes observed. This delay was fixed.
- With certain TOFD setups, a mismatch between the wedge angle value from the menus and from the
title bar could be observed. Both values are now linked and the mismatch was fixed.

OmniPC 4.1R9 2014-07-16

New features
- Support of the files generated with the 8ch UT module.
- Support of the RollerFORM Phased Array wheel probe.

OmniPC 4.1R8 2014-04-30

New features
- Support of the files generated with a PA2 32:128 module.
- AdBr reading functionality.
o AdBr gives the difference in dB between the signal maximum amplitude in Gate A and the
Reference level.
o Once the Reference Gain is set, the adjustment gain will not impact the AdBr value. Example:
 Gain = 20.0dB, A% = 40%, AdBr = -6dB
 Set the Reference Gain and add 6dB of adjustment gain
 Gain = 20.0dB + 6.0dB, A% = 80%, AdBr = -6dB
o A%r gives the % equivalent to the AdBr reading.
o The signal amplitude has to be lower than 100% for the reading to return a value.
o The same readings (AdBr and A%r) exist for Gate B.

Resolved issues from previous version


- During TOFD analysis using the knob, it happened that the cursors skipped a position. This situation
was fixed and the cursor movement respects the increment (delta) value.

OmniPC 4.1R7

New features
- Improvements to the Technique function
o The parameters defined by this function allow a better usability
- The technique “Uncorrected” was added to the list of existing techniques
o This button allows the S-Scan to be displayed in the form of stacked A-Scans
o The only layouts available are: A-S Scan and A-C-S Scan
- The A-Scan readings are displayed by default with TOFD configuration. This allows monitoring the
amplitude of the signal at the cursor’s position.

Resolved issues from previous version


- Files configured in “Clicker + Preset” mode are supported
- Longer file paths can be used and will be remembered by the software

OmniPC 4.1R6

New features
- The TOFD calibration shortcut is now available at all time through the interactive menu
o The user no longer has to go through the Wizard first
- Improvements to the different TOFD calibrations
o Better LW synchronisation
o The cursors position remains the one defined by the user prior to the Wizard

Resolved issues from previous version


- The OmniPC file path will now be initialized as well when opening a file directly from its folder
o The path used to only be initialized when selecting a file from the OmniPC file manager

OmniPC 4.1R3
New features
The A-Scan was added to the Multiple PA C-S layout, which now becomes PA A-C-S

DGS with limited functionality


- For Phased Array DGS, and Conventional UT at 45°, 60° or 70° angle beam
o Calibration is limited to the K1/IIW block
o Maximum ERS value is 10mm, if the value exceeds it, the reading will display the following: ---
o The Registration Level can be modified after completion of the calibration, and the calibration
will still be valid.
- For Conventional UT at 0°
o Calibration is limited to Flat Bottom Holes (FBH)
o If the Registration Level is modified after the DGS calibration, the calibration needs to be re-
done.

Resolved issues from previous version


- Many display refresh issues of the multi group layouts were fixed.
- The Reference curve automatically appears on the A-Scan when activating a Sizing calibration.

OmniPC 4.1R2

New features
- New report templates to reflect the nature of the application
- High quality sample data files are provided through the data file manager
- Interactive menus giving direct access to parameters that are linked to the click area
- Improved TOFD calibration, and Lateral Wave Synchronization
- 0% reference line is added to the TOFD A-Scan
- New Interactive title bar for direct access to the most common features
- The axis zoom bar is strictly used to Pan
o Double-tap to zoom out one axis
o Tap and hold, then select Zoom out for all axis at the same time
- Cursors are moved by selecting it, and then scrolling the rotary knob
- Gates are adjusted by selecting a zone of the gate, and then scrolling the rotary knob
o Left end = Start
o Middle = Threshold
o Right end = Width
- Additional layouts from MXU 4.0

Resolved issues from previous version


- The A-Scan is resized compared to MXU 4.0 to allow more precise measurements