This document outlines release notes for multiple versions of firmware for a device. It details fixes and improvements to things like communication protocols, time synchronization, algorithms, web interfaces, security, and hardware support across the various releases.

Uploaded by

abhishek046
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
137 views

XMU Firmware Release Notes 1.2.3.3

This document outlines release notes for multiple versions of firmware for a device. It details fixes and improvements to things like communication protocols, time synchronization, algorithms, web interfaces, security, and hardware support across the various releases.

Uploaded by

abhishek046
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
You are on page 1/ 3

version 1.2.

3
--------------
- ModBus TCP server connection will now timeout rapidly if communication is broken
while transmitting data.
- Correctly detects the event of the loss of the current time on the Real Time
Clock (RTC).
- Fix an issue in ModBus TCP server where interrupted communication could result in
communication error.
- Includes Boot code update (1.0.5) to fix an issue where ethernet communication
would not work at power-on after the unit has been offline for several days.

version 1.2.2
--------------
- Signaling relays are always enabled.
- Fixed an issue where a disabled PTP-1588 port cannot be re-enabled until restart.
- Improved digital input publication latency.
- Time synchronization will now turn unsynchronized if the occurence of a leap
second possible and not known.
- In PTP-1588, if the configured class is master only, ports will stay in
initialize state until UTC information is comfirmed.
- Fixed a very rare issue where digital input chatter filter may trigger when it
should not.
- Added automatic logout when the web browser close an online session.
- Fixed an issue with quality field of digital point in the GOOSE publisher.
- WEB: Fixed user profile page update issue after re-login as a different user.
- Fixed some issues in PTP/1588 when acting as a boundary clock.
- PMU: Updated ICD file of PMU010000 to reflect added functionalities when the
IEC61850-9-2 option is present.
- PMU: Fixed an issue with C37.118 custom command not being correctly blocked if
disabled.
- Fixed display of digital IOs on RTS models.
- Changed GOOSE publisher to be active also when the device is offline.
- Reworked GOOSE publisher retransmission scheme to use only min and max value.
- Removed IEC61850-9-2 version parameter which is not used anymore.
- Fixed potential issue when a very high rate of multicast traffic is received on
multiple ports.
- PMU: Fixed a connection issue in C37.118 UDP transport mode when using wildcard
as peer address.
- Improved precision of timestamping in digital IOs, and added supports of leap
second identification.
- Fixed an issue regarding 3-phase value quality when voltage or current neutral
input are disabled.
- Reworked time jump handling to make it smoother and make sure that no invalid
readings are published.
- Fixed an issue when changes to IED name are not applied correctly after system
configuration update.
- Fixed NTP client handling of leap seconds.
- ***WARNING*** Updated ICD files to includes digital outputs and reflect changes
to GOOSE dataset.
- ***WARNING*** Reworked GOOSE reported dataset to include digital outputs and use
data attributes instead of data objects.
- Fixed issue with pulsed output when using long pulse delay.
- PMU: Fixed handling of leap seconds in C37.118 stream.
- Fixed reloading of custom security certificate after deploying a new one.
- Reworked NTP Client to allow the system to synchronize without using a PPS input.
- Added various events to audit log.

version 1.2.1
--------------
- Fixed an issue encountered when receiving incoming C37.118 connections while
stopping the unit.

version 1.2.0
--------------
- Fixed signalization relays assignment to match documentation.
- Support for optional AMU software option on PMU product.
- Local management console now use role based access control for sensitive
commands.
- Added NTP server support.
- Added digital values to web HMI.
- PMU: Added C37.118 support for custom control commands.
- PMU: Fixed issue with C37.118 TCP-UDP communication mode.
- Fixes internal GPS firmware issue when extracting current TAI to UTC offset.
- Added ModBus slave protocol support.
- Role Base Access Management tool added to Web application.

version 1.1.6
--------------
- Added support for real-time simulator version of the product (low voltage).

version 1.1.5
--------------
- Added GPS module version and serial number on the System Information web page.
- Fixed input values quality indication when the input is detecting an overflow or
a failure.
- PMU: Fixed input angle correction issue that may cause a millidegree offset on
the reported angle if operated off frequency for an extended period.
- Added support for latest GPS receiver module version.

version 1.1.4
--------------
- Fixed wrong GoCB reference sent in GOOSE publisher.
- Changed content of published GOOSE message to include signalization relay
indicators.
- PMU: Improved PMU algorithm performance, V15.3
- Added Alarm(s) signalization to assigned LED and relay.
- Invert relay polarity of the synchronization status relay (R2)
- Updated self-signed certificate to use SHA-256 signing.

version 1.1.3
--------------
- PMU: Improved PMU algorithm performance, V15.2

version 1.1.2
--------------
- Device will now refuse some configuration that are invalid.
- PMU: Improved PMU algorithm performance, V15.1

version 1.1.1
--------------
- PMU: C37.118 reporting #2 might not work correctly if it is the only one enabled.
- PMU: Improved PMU algorithm performance, V15
- Fixed issue when special character is used in identification fields.
- Enforce password minimum length to 8 characters.

version 1.1.0
--------------
- Changed the accepted firmware update filename.
- Fixed an issue where unit might not return online after restart.
- Added strong password enforcement.
- Added power metering and sequences readings to web interface.
- Added test mode support.
- PMU: Major improvements to web dashboard. It now includes Summary, Measurements,
Synchrophasor, Alarms and Time synchronization panels.
- PMU: Set Phasor vector color to default color on older configurations.
- Fixed an issue preventing the web interface to display on iOS devices.
- PMU: Added ROCOF value to the synchophasor page of the Web interface.
- PMU: In C37.118, added configurability of configuration change count.
- Fixed save to file issues for DebugLevel properties.
- Fixed timezone handling and localtime display in journals.
- PMU: Improved PMU algorithm performance, V14.6
- Added proper handling of IO cards not responding or in error.
- Fixed compatibility issue with IE 11 web browser.
- Added boundary clock support.
- Added PTP-1588 Profiles support (default, C37.238 and IEC61850-9-3).
- Added PRP (Parallel Redundancy Protocol) functionality.
- Fixed an ethernet communication issue where the traffic can stop or experience
latencies.
- Added GPS status information in the web dashboard time synchronization page.
- Added leap second support.
- Added missing hardware information in the web System page.
- Added detailed view of current system alarms.
- Fixed typos in web site.

version 1.0.4
--------------
- Fixed calibration issue on voltage inputs of some units.
- Fixed issue in PTP/1588 synchronization when using P2P delay mechanism.
- Fixed IRIG-B parity check to work with inverted clock src polarity due to
ambiguous C37.118 definition.
- Fixed wrong offset for the GPS synchronization.

version 1.0.3
--------------
- Added support for PTP-1588 VLAN configuration.

version 1.0.2
--------------
- PMU: Updated phasor computation algorithm to v11.

version 1.0.1
--------------
- Fixed issue where device does not create the correct configuration templates when
reset to factory default.
- Fixed issue to display synchronization source as "None" if no clock source is
configured.
- Fixed issue where the WEB server page all the dynamic values are temporarily
displaying zero.

version 1.0.0
--------------
- Initial release